Record Display for the EPA National Library Catalog

RECORD NUMBER: 10 OF 32

Main Title Conceptual Designs and Cost Estimates for E-SOx Retrofits to Coal-Fired Utility Power Plants.
Author Becker, D. F. ; DuBard, J. L. ;
CORP Author Gilbert/Commonwealth, Inc., Reading, PA. ;Southern Research Inst., Birmingham, AL.;Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab.;Department of Energy, Washington, DC.
Year Published 1987
Report Number GAI-2697; EPA/600/7-87/028;
Stock Number PB88-143995
Additional Subjects Sulfur dioxide ; Pollution ; Electric power plants ; Design criteria ; Cost estimates ; Bituminous coal ; Sulfur ; Removal ; Capitatized costs ; Ignition ; Periodic variations ; Concepts ; Tables(Data) ; Coal-Fired MHD generators ; Retrofits
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB88-143995 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 78p
Abstract
The report describes a conceptual design and cost estimate, based on information available at the beginning of 1987, for six cases of a retrofit of the E-SOx process to a utility. The annualized cost ranged from $301 to $378 per ton of SO2 removed. The generic cost basis, used for other cost estimates, was used in this study and applied to a 500 MWe utility burning eastern medium-sulfur (2.5%) bituminous coal. Capital costs compare very favorably with other retrofit SO2 removal technologies. Sorbent or reagent cost is the largest single component of the costs.