Record Display for the EPA National Library Catalog

RECORD NUMBER: 7 OF 142

Main Title An evaluation of full scale fabric filters on utility boilers : SPS Harrington Station Unit 3 /
Author Richardson, John W. ; Richardson, J. W. ; McKenna, J. D. ; Mycock, J. C.
Other Authors
Author Title of a Work
Mycock, John C.
McKenna, John D.
CORP Author ETS, Inc., Roanoke, VA.;Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab.
Publisher GPO,
Year Published 1985
Report Number EPA/600/7-85/031A; EPA-68-02-3649
Stock Number PB85-235513
Subjects Fabric filters ; Coal-fired power plants ; Filters and filtration ; Contamination (Technology) ; Coal--Combustion
Additional Subjects Air pollution control equipment ; Boilers ; Particles ; Air filters ; Electric power plants ; Industrial wastes ; Combustion products ; Performance evaluation ; Design criteria ; Combustion modification ; Fabric filters ; Coal fired power plants ; Southwestern Public Service's Harrington Station ; Baghouses
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB85-235513 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 168 pages : illustrations
Abstract
The report gives results of total mass and fractional size particulate emission tests at Southwestern Public Service's Harrington Station Unit 3 from July 8 to 11, 1981, as part of a program to evaluate and characterize the performance of full-scale fabric filter units installed on 100 MW or larger coal-fired power plants. Three outlet and one inlet mass and fractional size emission tests were performed. Due to the absence of inlet ports, inlet testing was done by bypassing the baghouse and testing at the outlet ports of the fabric filter.
Notes
"July 1985." "EPA-600/7-85/031a." "EPA Contract No. 68-02-3649." "Final report period 6/81 - 6/85." Microfiche.