Main Title Comparison of Verification Procedures for the Membrane Filter Total Coliform Technique.
Author LeChevallier, M. W. ; Cameron, S. C. ; McFeters, G. A. ;
CORP Author Montana State Univ., Bozeman. Dept. of Microbiology.;Environmental Protection Agency, Cincinnati, OH. Water Engineering Research Lab.
Year Published 1983
Report Number EPA-R-807092; EPA/600/J-83/309;
Stock Number PB85-236255
Additional Subjects Coliform bacteria ; Microbiology ; Potable water ; Sampling ; Tests ; Fluid filters ; Membranes ; Galactosidase ; Cytochrome oxidase ; Accuracy ; Reprints ; Drinking water
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB85-236255 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 4p
Abstract
Verification of membrane filter total coliform colonies from drinking water was increased 87% by testing for the presence of beta-galactosidase and cytochrome oxidase, compared with verification by determination of gas production in lauryl tryptose broth. Over 90% of the coliforms verified by testing for beta-galactosidase and cytochrome oxidase were representative of the typical coliform genera. (Copyright (c) 1983, American Society for Microbiology.)