Record Display for the EPA National Library Catalog

RECORD NUMBER: 24 OF 36

Main Title Method 524.3: Measurement of Purgeable Organic Compounds in Water by Capillary Column Gas Chromatography/Mass Spectrometry, Version 1.0.
Author B. Prakash ; A. D. Zaffiro ; M. Zimmerman ; D. J. Munch ; B. V. Pepich
CORP Author Environmental Protection Agency, Cincinnati, OH. Office of Ground Water and Drinking Water.
Year Published 2009
Report Number EPA/815/B-09/009
Stock Number PB2010-101384
Additional Subjects Purgeable organic compounds ; Drinking waters ; Measurement ; Gas chromatography/mass spectrometry ; Selected analytes ; Reagent water ; Groundwater source ; Surface water source ; Gas chromatography/mass spectometry (GC/MS) method ; Selected ion monitoring (SIM) ; Selected ion storage (SIS)
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB2010-101384 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 55p
Abstract
This is a gas chromatography/mass spectrometry (GC/MS) method for the determination of purgeable organic compounds in finished drinking waters. Discontinuous scanning modes such as selected ion monitoring (SIM) and selected ion storage (SIS) are permitted for determining selected analytes that are monitored at levels too low for the full scan detection mode. Precision and accuracy data have been generated for the method analytes in reagent water, drinking water from a groundwater source, and drinking water from a surface water source. The single laboratory Lowest Concentration Minimum Reporting Level (LCMRL) has also been determined in reagent water.