Main Title |
EPA industrial boiler FGD survey : fourth quarter 1978 / |
Author |
Tuttle, J. ;
Patkar, A. ;
Welch, D. ;
Hessling, M. ;
Eckstein, M. ;
|
Other Authors |
|
CORP Author |
PEDCo-Environmental, Inc., Cincinnati, OH.;Industrial Environmental Research Lab., Research Triangle Park, NC. |
Publisher |
U.S. Environmental Protection Agency, Industrial Environmental Research Laboratory ; Available to the public through the National Technical Information Service, |
Year Published |
1979 |
Report Number |
EPA-600/7-79-067a; EPA-68-02-2603 |
Stock Number |
PB-292 385 |
OCLC Number |
07622583 |
Subjects |
Flue gases--Desulfurization ;
Boilers ;
Factory and trade waste--Environmental aspects--United States ;
Flue gases--Desulphurization
|
Additional Subjects |
Air pollution control ;
Boilers ;
Sulfur dioxide ;
Performance evaluation ;
Industrial wastes ;
Combustion products ;
Solid waste disposal ;
Design criteria ;
Tables(Data) ;
Flue gases ;
Cost analysis ;
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EKBD |
EPA-600/7-79-067a |
|
Research Triangle Park Library/RTP, NC |
12/19/2003 |
ELBD ARCHIVE |
EPA 600-7-79-067a |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
ESAD |
EPA 600-7-79-067A |
|
Region 10 Library/Seattle,WA |
03/23/2010 |
NTIS |
PB-292 385 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
vii, 223 p. : ill. ; 28 cm. |
Abstract |
The report gives detailed technical information concerning application of flue gas desulfurization (FGD) systems to industrial boilers. Design and operation data is presented for 172 FGD control systems (132 of them operational), designed to control SO2 emissions from 206 industrial boilers at 61 plants. With a 1978 capacity of 9.2 million scfm, an average of more than seven new FGD systems have been put on line each year since 1972. Information in the report was obtained by a survey of plant personnel, control system vendors, regulatory agencies, and consulting engineering firms. The data is given in two types of tables: one gives summary information; the other, detailed information. Summary tables present information as a function of control process, control system vendor, disposal technique, operational status, startup date, and flue gas capacity. Detailed information includes: control system design, economics, operating experience, problems and solutions, waste disposal techniques, and maintenance practices. |
Notes |
"PEDCo Environmental, Inc." "Industrial Environmental Research Laboratory, Office of Energy, Minerals, and Industry." "February 1979." "Contract no. 68-02-2603, task no. 45, program element no. EHE624." |