Record Display for the EPA National Library Catalog

RECORD NUMBER: 21 OF 369

Main Title Applicability of the thermal DeNOx process to coal-fired utility boilers /
Author Varga, Jr., G. M. ; Tomsho, M. E. ; Ruterbories, B. H. ; Smith, G. J. ; Bartok., W.
Other Authors
Author Title of a Work
Varga, G. M.
CORP Author Exxon Research and Engineering Co., Linden, NJ. Government Research Labs.;Industrial Environmental Research Lab., Research Triangle Park, NC.
Publisher Industrial Environmental Research Laboratory ; National Technical Information Service [distributor],
Year Published 1979
Report Number EPA 600-7-79-079; EPA-68-02-2649
Stock Number PB-295 830
OCLC Number 08271895
Subjects Coal-fired furnaces ; Combustion gases--Purification
Additional Subjects Air pollution control ; Nitrogen oxides ; Boilers ; Ammonia ; Coal ; Flue gases ; Cost estimates ; Performance evaluation ; Denitrification ; Thermal deNOx process
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=9101R7IA.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJBD  EPA 600-7-79-079 Headquarters Library/Washington,DC 01/16/2020
ELBD ARCHIVE EPA 600-7-79-079 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ESAD  EPA 600-7-79-079 Region 10 Library/Seattle,WA 03/23/2010
NTIS  PB-295 830 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 1 volume (various pagings) : illustrations ; 28 cm.
Abstract
The report gives a projection of the performance and cost of the Exxon Thermal DeNOx Process applied to coal-fired utility boilers. Eight units were selected, representing different boiler manufacturers, sizes, firing methods, and coal types. Thermal DeNOx performance was projected both with and without combustion modifications for all boilers at full load and at one or more loads down to 50%. Three NOx reduction targets were used: the proposed New Source Performance Standards (NSPS), reduction to about two-thirds of the proposed NSPS, and the maximum practical NOx reduction that could be achieved. All costs are for full load. Thermal DeNOx was projected to be equally applicable for all boilers studied, despite significant differences in flue gas temperatures and flow paths. Maximum Thermal DeNOx performance ranged from 50 to 59% for the boilers studied. Costs ranged from 0.25 to 1.23 mills/kWh, excluding preliminary engineering costs and licensing royalties. A full-scale demonstration of Thermal DeNOx on a coal-fired utility boiler is recommended, including investigation of potential downstream effects of the process.
Notes
"EPA 600-7-79-079." "Exxon Research and Engineering Company, Government Research Laboratories." "March 1979." Cover title. Includes bibliographical references. "Contract no. 68-02-2649, program element no. EHE624A."