Record Display for the EPA National Library Catalog

RECORD NUMBER: 1 OF 2

Main Title Instrumentation for the determination of nitrogen oxides content of stationary source emissions /
Other Authors
Author Title of a Work
Synder, Arthur D.
CORP Author United States. Environmental Protection Agency. National Environmental Research Center.
Publisher U.S. Environmental Protection Agency, National Environmental Research Center ; For sale by the National Technical Information Service,
Year Published 1972
Report Number MRC-DA-317; EHSD 71-30; EPA/APTD-0847; MRC-DA-317 EHSD 71-30; EPA-EHSD-71-30; 0942; APTD0847V1
Stock Number PB-209190 (v.2); PB-204 877 (v.1)
OCLC Number 29547558
Subjects Air--Pollution--Measurement
Additional Subjects ( Air pollution ; Nitrogen oxides) ; ( Gas detectors ; Nitrogen oxides) ; ( Flue gases ; Gas detectors) ; Monitors ; Performance evaluation ; Field tests ; Electric power plants ; Ultraviolet spectroscopy ; Infrared spectroscopy ; Electrochemistry ; Accuracy ; Combustion products ; Sensitivity ; Humidity ; Air pollution detection
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=91023EL7.PDF
Vol. I https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=94004E65.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
ELBD ARCHIVE EPA APTD-0847 v. II Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ESAD  APTD-0847 v.1 Region 10 Library/Seattle,WA 01/02/1998
ESAD  APTD-0942 v.2 Region 10 Library/Seattle,WA 10/06/2016
NTIS  PB-209 190 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation volumes (2-) : illustrations ; 28 cm
Abstract
The performance of seven commercial monitors for applicability to the continuous determination of nitrogen oxides from stationary sources was evaluated. Based on the present and projected requirements in stationary source emissions monitoring, the ranking, utility factors and ranges of performance were first established for each of fifteen performance parameters. These desired instrument parameters formed matrix against which the quantified performance values as measured in the laboratory and on an operating power plant flue gas composition could be compared. The comparison of the evaluation data on each performance parameter with the desired performance matrix resulted in an estimate of overall performance of the tested nitrogen oxide monitors. This overall performance is calculated in the form of an 'index of performance' for each instrument. (Author)
Notes
"January 1972." "EPA/APTD-0847." Prepared by Monsanto Research Corporation, Dayton Ohio, under contract no. EHSD 71-30. PB-209 190 (v.2).