Main Title |
Applicability of the thermal DeNOx process to coal-fired utility boilers / |
Author |
Varga, Jr., G. M. ;
Tomsho, M. E. ;
Ruterbories, B. H. ;
Smith, G. J. ;
Bartok., W.
|
Other Authors |
|
CORP Author |
Exxon Research and Engineering Co., Linden, NJ. Government Research Labs.;Industrial Environmental Research Lab., Research Triangle Park, NC. |
Publisher |
Industrial Environmental Research Laboratory ; National Technical Information Service [distributor], |
Year Published |
1979 |
Report Number |
EPA 600-7-79-079; EPA-68-02-2649 |
Stock Number |
PB-295 830 |
OCLC Number |
08271895 |
Subjects |
Coal-fired furnaces ;
Combustion gases--Purification
|
Additional Subjects |
Air pollution control ;
Nitrogen oxides ;
Boilers ;
Ammonia ;
Coal ;
Flue gases ;
Cost estimates ;
Performance evaluation ;
Denitrification ;
Thermal deNOx process
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJBD |
EPA 600-7-79-079 |
|
Headquarters Library/Washington,DC |
01/16/2020 |
ELBD ARCHIVE |
EPA 600-7-79-079 |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
ESAD |
EPA 600-7-79-079 |
|
Region 10 Library/Seattle,WA |
03/23/2010 |
NTIS |
PB-295 830 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
1 volume (various pagings) : illustrations ; 28 cm. |
Abstract |
The report gives a projection of the performance and cost of the Exxon Thermal DeNOx Process applied to coal-fired utility boilers. Eight units were selected, representing different boiler manufacturers, sizes, firing methods, and coal types. Thermal DeNOx performance was projected both with and without combustion modifications for all boilers at full load and at one or more loads down to 50%. Three NOx reduction targets were used: the proposed New Source Performance Standards (NSPS), reduction to about two-thirds of the proposed NSPS, and the maximum practical NOx reduction that could be achieved. All costs are for full load. Thermal DeNOx was projected to be equally applicable for all boilers studied, despite significant differences in flue gas temperatures and flow paths. Maximum Thermal DeNOx performance ranged from 50 to 59% for the boilers studied. Costs ranged from 0.25 to 1.23 mills/kWh, excluding preliminary engineering costs and licensing royalties. A full-scale demonstration of Thermal DeNOx on a coal-fired utility boiler is recommended, including investigation of potential downstream effects of the process. |
Notes |
"EPA 600-7-79-079." "Exxon Research and Engineering Company, Government Research Laboratories." "March 1979." Cover title. Includes bibliographical references. "Contract no. 68-02-2649, program element no. EHE624A." |