Main Title Field evaluation of aeration processes for organic contaminant removal from groundwater /
Author Ruggerio, Dominick D. ; Ruggiero, D. D. ; Feige, W. A. ; Ruggiero, Dominick.
Other Authors
Author Title of a Work
Feige, Walter A.
CORP Author Municipal Environmental Research Laboratory.; Nebolsine Kohlmann Ruggiero Engineers, New York.
Publisher Municipal Environmental Research Laboratory ; National Technical Information Service,
Year Published 1983
Report Number EPA/600/D-84/016; EPA-R-806355; PB84130384
Stock Number PB84-130384
OCLC Number 11313805
Subjects Organic water pollutants
Additional Subjects Organic water pollutants ; Water treatment ; Ground water ; Organic solvents ; Aeration ; Field tests ; Pilot plants ; Performance evaluation ; Tetrachloroethylene ; Chlorine organic compounds ; Operating costs ; Capitalized costs ; Sampling ; Design criteria ; Volatile organic compounds ; Ethylene/dichloro ; Ethylene/trichloro
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=910206A6.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EHAM  TD458.R83 Region 1 Library/Boston,MA 04/29/2016
ELBD ARCHIVE EPA-600-D-84-016 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ELBD RPS EPA 600-D-84-016 repository copy AWBERC Library/Cincinnati,OH 04/03/2020
NTIS  PB84-130384 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation ii, 24 pages : illustrations ; 28 cm.
Abstract
The results of the pilot plant evaluation of aeration methods for the removal of volatile organic solvents from ground water are presented. The project took place at Glen Cove, Long Island, New York, where the concentration of cis-1,2-dichloroethyene, trichloroethylene, and tetrachloroethylene in that community's well water exceeded State Guidelines. Several aeration approaches were examined, including diffused aeration, packed column diffused aeration, cooling tower aeration, induced air spray aeration (with and without packing), packed column air-stripping, and air-lift pumping. Air discharging from some of the units was sampled for potential air pollution problems. Capital and operating costs were estimated for full-scale installations. Several of the systems evaluated reduced contaminant levels to meet present New York State guidelines.
Notes
Includes bibliographical references (page 9). Published in AWWA Proceedings-National Meeting 1983.