Record Display for the EPA National Library Catalog

RECORD NUMBER: 24 OF 121

Main Title Determination of Sulfur Dioxide, Nitrogen Oxides, and Carbon Dioxide in Emissions from Electric Utility Plants by Alkaline Permanganate Sampling and Ion Chromatography.
Author Margeson, J. H. ; Knoll, J. E. ; Midgett, M. R. ; Oldaker, G. B. ; Reynolds, W. E. ;
CORP Author Environmental Monitoring Systems Lab., Research Triangle Park, NC. ;Entropy Environmentalists, Inc., Research Triangle Park, NC.
Year Published 1985
Report Number EPA/600/J-85/141;
Stock Number PB86-101185
Additional Subjects Air pollution control ; Gas analysis ; Manuals ; Electric power plants ; Chemical analysis ; Sulfur dioxide ; Nitrogen oxides ; Carbon dioxide ; Sampling ; Industrial wastes ; Combustion products ; Oxidation ; Reprints ; Alkaline permanganate sampling ; Ion chromatography ; Air pollution detection
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB86-101185 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 7p
Abstract
A manual 24-h integrated method for determining SO2, NOx, and CO2 in emissions from electric utility plants was developed and field tested downstream from an SO2 control system. Samples were collected in alkaline potassium permanganate solution contained in restricted-orifice impingers. Samples were analyzed by ion chromatography. The method showed 100% collection efficiency for all three pollutants at a sample flow rate of 35 cu cm/min and was found to be unbiased relative to independent monitoring systems. Further work is needed to determine the error in the SO2 determination caused by H2SO4 absorption.