Main Title CairPol CairClip O(sub 3)-NO(sub 2) Citizen Science Operating Procedure.
Author Williams, R. ; Kaufman, A. ; Garvey, S.
CORP Author Environmental Protection Agency, Research Triangle Park, NC.; Oak Ridge Inst. for Science and Education, TN.
Year Published 2015
Report Number EPA/600/R-15/117
Stock Number PB2015-105134
Additional Subjects Citizen science ; Portable sensor ; Monitoring ; Operating procedure ; Air quality modeling ; Guidelines ; Battery power ; Citizen Science Operating Procedure
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=P100MOXD.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB2015-105134 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 19p
Abstract
The CairPol CairClip O(sub 3)-NO(sub 2) is a lightweight, portable sensor for measuring ozone (O3) and nitrogen dioxide (NO2) in parts per billion (ppb) or micrograms per cubic meter (µg/m3) in applications such as personal exposure and indoor and outdoor air quality monitoring. It uses a micro fan to actively sample air. The CairClip can run on battery power for approximately 24 hours, but it can also operate continuously for much longer periods when plugged into a power source. This operating procedure explains what you need to do to collect quality O3 and NO2 data using the CairClip sensor for your monitoring project.