Main Title |
Procedures for estimating dry weather pollutant deposition in sewerage systems / |
Author |
Pisano, William C., ;
Queiroz., Celso
|
Other Authors |
|
CORP Author |
Municipal Environmental Research Laboratory.; Energy and Environmental Analysis, inc. |
Publisher |
Environmental Protection Agency, Office of Research and Development, Municipal Environmental Research Laboratory, |
Year Published |
1977 |
Report Number |
EPA-600/2-77-120; EPA-R-804579 |
Stock Number |
PB-270 695 |
OCLC Number |
03201559 |
ISBN |
pbk. |
Subjects |
Combined sewers--Mathematical models ;
Sewage disposal--Mathematical models
|
Additional Subjects |
Combined sewers--Mathematical models ;
Sewage disposal--Mathematical models ;
Flushing ;
Water pollution abatement ;
Mathematical models ;
Solids ;
Accumulation ;
Maintenance ;
Pipes ;
Slope ;
Rainfall ;
Biochemical oxygen demand ;
Phosphorus ;
Nitrogen ;
Regression analysis ;
Tables(Data) ;
Field tests ;
Suspended solids
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJBD ARCHIVE |
EPA 600-2-77-120 |
|
Headquarters Library/Washington,DC |
01/11/2011 |
EJBD |
EPA 600-2-77-120 |
|
Headquarters Library/Washington,DC |
03/08/2014 |
ELBD |
EPA 600-2-77-120 |
|
AWBERC Library/Cincinnati,OH |
08/06/1993 |
ESAD |
EPA 600-2-77-120 |
|
Region 10 Library/Seattle,WA |
03/23/2010 |
NTIS |
PB-270 695 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
xii, 92 pages : illustrations, figures, tables ; 28 cm. |
Abstract |
A set of generalized procedures for estimating pollutant loadings associated with dry weather sewage solids deposition in combined sewer systems has been prepared to provide planners, engineers and municipal managers with technical information so that they can make intelligent informed decisions on potential sewer flushing programs in combination with other combined sewer management controls. The predictive equations relate the total daily mass of pollutant deposition accumulations within a collection system to physical characteristics of collection systems such as per capita waste rate, service area, total pipe length, average pipe slope, average diameter and other more complicated parameters that derive from analysis of pipe slope characteristics. Pollutant parameters include suspended solids, volative suspended solids, biochemical oxygen demand, chemical oxygen demand, total organic nitrogen and total phosphorous. Sewer system age and degree of maintenance was also considered. Factors are presented for estimating the increase in collection system deposition resulting from improper maintenance. |
Notes |
"Prepared by Energy and Environmental Analysis, Inc., Boston, Mass., under Grant no. R804579." "July 1977."" Includes bibliographical references (page 70). |