Record Display for the EPA National Library Catalog

RECORD NUMBER: 4 OF 4

Main Title Passive sampling device for ambient air and personal monitoring {microform} /
Author Wooten, G. W. ; Strobel, J. E. ; Pustinger, J. V. ; McMillin, C. R.
Other Authors
Author Title of a Work
Wooten, G. W.
CORP Author Monsanto Co., Dayton, OH.;Environmental Monitoring Systems Lab., Research Triangle Park, NC.
Publisher U.S. Environmental Protection Agency, Environmental Monitoring Systems Laboratory,
Year Published 1984
Report Number EPA/600/4-84/050; EPA-68-02-3469
Stock Number PB84-210046
Subjects Air quality management--United States ; Environmental monitoring--United States
Additional Subjects Gas detectors ; Monitors ; Dosimeters ; Air pollution ; Performance evaluation ; Design criteria ; Sorbents ; Gas analysis ; Chemical analysis ; Sampling ; Diffusion ; Field tests ; Passive monitors ; Volatile organic compounds ; Air pollution detection
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB84-210046 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 72 p. : ill. ; 28 cm.
Abstract
A high performance passive dosimeter has been developed and evaluated as a monitor for volatile organics in ambient air and for short-term, low-level personal monitoring applications. The dosimeter design was dictated by three major areas of concern: (1) diffusive mass transport considerations; (2) sorbent selection, and (3) chemical quantitation of the collected compounds, which intimately involves desorption procedures of the passive device.
Notes
Caption title. "June 1984." "EPA-600/4-84-050." Microform.