Record Display for the EPA National Library Catalog

RECORD NUMBER: 7 OF 7

Main Title Technical assistance document for the calibration of ambient ozone monitors /
Author Paur, Richard J.
Other Authors
Author Title of a Work
Paur, Richard J.
McElroy, Frank F.
CORP Author Environmental Monitoring and Support Lab., Research Triangle Park, NC.
Publisher Environmental Monitoring and Support Laboratory, Office of Research and Development, U.S. Environmental Protection Agency ; Available from N.T.I.S.,
Year Published 1979
Report Number EPA-600/4-79-057
Stock Number PB80-149552
OCLC Number 13198778
Additional Subjects Air pollution ; Photometers ; Ozone ; Calibrating ; Gas analysis ; Ultraviolet spectroscopy ; Design ; Performance evaluation ; Error analysis ; Concentration(Composition) ; Laboratory equipment ; Chemical analysis ; Air pollution detection ; Procedures
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=20012VKF.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJBD  EPA 600-4-79-057 Headquarters Library/Washington,DC 10/19/2015
EKBD  EPA-600/4-79-057 Research Triangle Park Library/RTP, NC 04/14/2014
ELBD ARCHIVE EPA 600-4-79-057 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ERAD  EPA 600/4-79-057 Region 9 Library/San Francisco,CA 10/29/2012
ESAD  EPA 600-4-79-057 Region 10 Library/Seattle,WA 03/23/2010
NTIS  PB80-149552 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation p. cm.
Abstract
In February, 1979, EPA revised certain parts of the ambient air pollution monitoring regulations (40 CFR Part 50, Appendix D) to specify a new procedure for calibration of ambient ozone analyzers. The new procedure is based on ultraviolet (UV) absorption photometry, and specifies in detail the UV photometer, other apparatus, and the procedure necessary for establishing quasi-primary ozone concentration standards derived from the known absorption coefficient of ozone at 254 nm. This Technical Assistance Document is intended to provide information and assistance to State monitoring agencies and other organizations which must use the new procedure to calibrate ambient ozone analyzers. The first section of the document is a discussion of absorption photometry, with emphasis on the transmittance measurement and measurement errors. Section 2 provides step-by-step explanatory information and advice keyed to each paragraph of the procedure. Section 3 discusses UV photometers specifically, their design and operational characteristics, and several commercially available models.
Notes
"September 1979"--Cover. "EPA-600/4-79-057."