Main Title |
Particulate control at high temperature and pressure using augmented granular bed filters / |
Author |
Yung, S. ;
Patterson, R. G. ;
Calvert, Seymour
|
Other Authors |
|
CORP Author |
A.P.T., Inc., San Diego, CA.;Industrial Environmental Research Lab., Research Triangle Park, NC. |
Publisher |
U.S. Environmental Protection Agency, Industrial Environmental Research Laboratory ; National Technical Information Service [distributor, |
Year Published |
1980 |
Report Number |
EPA-600/7-80-035; EPA-68-02-2183 |
Stock Number |
PB80-200819 |
OCLC Number |
08276820 |
Subjects |
Filters and filtration--Environmental aspects ;
Electrostatic separators--Testing
|
Additional Subjects |
Air pollution control equipment ;
Particles ;
High temperature tests ;
High pressure tests ;
Electrostatics ;
Performance evaluation ;
Filtration ;
Industrial wastes ;
Combustion products ;
Graphs(Charts) ;
Granular bed filters
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EKBD |
EPA-600/7-80-035 |
|
Research Triangle Park Library/RTP, NC |
01/16/2004 |
ELBD ARCHIVE |
EPA 600-7-80-035 |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
ESAD |
EPA 600-7-80-035 |
|
Region 10 Library/Seattle,WA |
03/23/2010 |
NTIS |
PB80-200819 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
x, 94 p. : ill. ; 28 cm. |
Abstract |
The report gives results of experimental measurements (in fixed- and moving-bed filters) of the effect of electrostatic augmentation on granular bed filter particle collection efficiencies. Experimental findings included: (1) either polarizing the bed or charging the particles significantly increased the collection efficiency of the filter (efficiency increased with increasing applied voltage across the bed); (2) both polarizing the bed and charging the particles caused the bed to become very efficient in collecting particles (efficiency of a 15 cm deep bed of 1.6 mm diameter alumina spheres with a polarizing field strength of 1.31 kV/cm was above 98% for all particle sizes); (3) polarizing the bed and/or charging the particles has no effect on pressure drop across a clean bed; (4) a filter cake increases the collection efficiency of the granular bed filter (the increase depends on the cake structure and the amount of dust retained in the beds); (5) DC polarization is much more effective than low frequency AC polarization; and (6) fixed bed filters show a higher collection efficiency and a higher pressure drop than moving beds (in moving beds, lower recirculation rates also have lower rates of attrition of retaining grids and granules and lower rates of dislodging and reentraining the collected particles). |
Notes |
"A.P.T., Inc." "February 1980." Bibliography: p. 45. "Contract no. 68-02-2183, program element no. EHE624A." |