Record Display for the EPA National Library Catalog

RECORD NUMBER: 16 OF 16

Main Title Transportable continuous emission monitoring system operational protocol : instrumental monitoring of SO2, NOx, CO2, and O2 effluent concentrations /
Author Peeler, James W.
Other Authors
Author Title of a Work
Paley, Louis R.
CORP Author United States. Environmental Protection Agency. Stationary Source Compliance Division.; Entropy Environmentalists.
Publisher Division, Office of Air Quality Planning and Standards,
Year Published 1983
Report Number EPA-340/1-83-016; EPA-68-01-6317
Stock Number PB84-126978
OCLC Number 10716377
Subjects Air--Pollution--United States--Measurement ; Environmental monitoring--United States ; Air--Pollution--Measurement
Additional Subjects Air--Pollution--United States--Measurement ; Environmental monitoring--United States ; Gas detection ; Portable equipment ; Air pollution ; Monitors ; Sulfur dioxide ; Nitrogen oxides ; Carbon dioxide ; Oxygen ; Concentration(Composition) ; Field tests ; Performance evaluation ; Sites ; Calibrating ; Sampling ; Design criteria ; Air pollution detection
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=2000B7MX.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJBD  EPA 340-1-83-016 Headquarters Library/Washington,DC 08/16/2011
EKBD  EPA-340/1-83-016 Research Triangle Park Library/RTP, NC 12/14/2001
ELBD ARCHIVE EPA 340-1-83-016 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ERAD  EPA 340/1-83-016 Region 9 Library/San Francisco,CA 12/31/2012
ESAD  EPA 340-1-83-016 Region 10 Library/Seattle,WA 03/23/2010
NTIS  PB84-126978 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation v, 49, 6, 9 pages : illustrations, 1 form ; 28 cm.
Abstract
A transportable continuous emission monitoring system (TCEMS) capable of providing reliable and accurate effluent measurements of SO2, NO/NOx, CO2, and/or O2 has been developed and field tested at numerous industrial and utility boilers. This report presents the operational protocol for the TCEMS, including set-up, operation, calibration, quality assurance, and data reduction procedures. The TCEMS and the operational protocol are designed for use in conducting source emission tests, continuous emission monitor (CEM) relative accuracy tests, and stratification tests. Extensive field testing has shown that the TCEMS can be set up, calibrated, and recording accurate and precise data within two to four hours after arrival at the site.
Notes
Final in-house. "Entropy Environmentalists, Inc." Distributed to depository libraries in microfiche. "January 1983." "EPA-340/1-83-016." Contract Number: 68-01-6317.