Record Display for the EPA National Library Catalog

RECORD NUMBER: 9 OF 16

Main Title Fluidized bed combustion : effectiveness of an SO2 control technology for industrial boilers /
Author Aul, E. F. ; Owen, M. L. ; Jones, A. F.
Other Authors
Author Title of a Work
Aul, Edward F.
Owen, M. L.
Jones, A. F.
Greenwald, Judith M.
CORP Author Radian Corp., Research Triangle Park, NC.;Environmental Protection Agency, Research Triangle Park, NC. Office of Air Quality Planning and Standards.
Publisher U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards ; National Technical Information Services [distributor],
Year Published 1984
Report Number EPA-45/3-85-010 [i.e. EPA-450/3-85-010]; PB85-197101; 68-01-6558; EPA-68-01-6558
Stock Number PB85-197101
OCLC Number 12142803
Subjects Fluidized-bed furnaces ; Sulfur dioxide ; Boilers
Additional Subjects Air pollution control ; Boilers ; Fluidized bed processors ; Sulfur dioxide ; Industrial wastes ; Combustion products ; Standards ; Performance evaluation ; Cost analysis ; Particles ; Flue gases ; Coal ; Fabric filters ; Flue gas desulfurization
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=2000MHYG.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EHAM  EPA-450/3-85-010 Region 1 Library/Boston,MA 05/26/2016
EKBD  EPA-450/3-85-010 Research Triangle Park Library/RTP, NC 01/30/1998
ELBD ARCHIVE EPA 450-3-85-010 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ESAD  EPA 450-3-85-010 Region 10 Library/Seattle,WA 07/03/2018
NTIS  PB85-197101 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 1 volume (various pagings) : illustrations ; 28 cm
Abstract
Atmospheric fluidized bed combustion (AFBC) boilers have developed rapidly over recent years and are now offered commercially in several different configurations. SO2 reduction levels of 90 percent and above have been achieved by coal-fired AFBC boilers in the industrial size category. Based on the data available, industrial FBC NOx emissions have been consistently below 0.5 lb/million Btu. PM emissions of less than 0.5 lb/million Btu have been routinely achieved with fabric filters. AFBC boiler system costs were compared with costs for a conventional boiler equipped with an FGD system and with costs for a conventional boiler using low sulfur compliance coal. The conclusions drawn from the economic analyses are that (1) studied cost difference between AFBC Technology, conventional boiler/FGD systems, and compliance coal combustion are projected to be small over the SO2 emission range of 1.7 to 0.8 lb/million Btu and SO2 reduction range of 65 to 90 percent, and (2) that cost competitiveness among these technologies is not expected to change significantly as the emission limitations change over this range. Absolute economic competitiveness among these options will be sensitive to site-specific parameters and decided on a case-by-case basis.
Notes
Final. Distributed to depository libraries in microfiche. "September 1984." "EPA/450-3-85-010." Includes bibliographical references. Contract Number: 68-01-6558.