Main Title |
Evaluation of reverse osmosis membranes for treatment of electroplating rinsewater / |
Author |
McNulty, Kenneth J., ;
Hoover, Peter R.
|
Other Authors |
|
CORP Author |
American Electroplaters' Society, Inc., Winter Park, FL.;Industrial Environmental Research Lab.-Cincinnati, OH. |
Publisher |
Industrial Environmental Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency, Available through the National Technical Information Service. |
Year Published |
1980 |
Report Number |
EPA-600/2-80-084; EPA-R-804311 |
Stock Number |
PB80-202385 |
OCLC Number |
13607423 |
Subjects |
Electroplating--Waste disposal ;
Sewage--Purification--Reverse osmosis process ;
Membranes (Technology)
|
Additional Subjects |
Sewage treatment ;
Osmosis ;
Membranes ;
Tests ;
pH ;
Chromic acid ;
Copper acid ;
Copper ;
Cyanimides ;
Zinc ;
Rinsing ;
Oxidizers ;
Electroplating ;
Reverse osmosis
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EHAM |
TD899.M43M36 1980 |
|
Region 1 Library/Boston,MA |
04/29/2016 |
EJBD |
EPA 600-2-80-084 |
|
Headquarters Library/Washington,DC |
04/05/2016 |
ELBD ARCHIVE |
EPA 600-2-80-084 |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
ELBD |
EPA 600-2-80-084 |
|
AWBERC Library/Cincinnati,OH |
12/05/1997 |
ERAD |
EPA 600/2-80-084 |
|
Region 9 Library/San Francisco,CA |
10/09/2012 |
ESAD |
EPA 600-2-80-084 |
|
Region 10 Library/Seattle,WA |
03/23/2010 |
NTIS |
PB80-202385 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
viii, 43 pages : illustrations ; 28 cm. |
Abstract |
Because of the limited pH range over which current commercially available reverse osmosis membranes can be applied, a test program was initiated to define the applicability of new membrane materials to the treatment of rinsewaters with extreme pH levels and high oxidant levels (chromic acid). Life tests were conducted with the PA-300, PBIL, NS-100, NS-200, SPPO, B-9, and CA membranes on rinsewaters from copper cyanide, zinc cyanide, acid copper, and chromic acid plating baths. The PA-300 membrane exhibited superior performance for the treatment of copper cyanide, zinc cyanide, and chromic acid rinsewaters, and further development and demonstration of this membrane is recommended. |
Notes |
Prepared by Walden Division of Abcor, Inc. for the American Electroplaters' Society Inc. under U.S. Environmental Protection Agency, Office of Research and Development, Industrial Environmental Research Laboratory, Cincinnati, Ohio, grant no. Contract Number: R804311. Includes bibliographical references (page 30). |