Main Title Sampling/analytical method evaluation for ethylene oxide emission and control unit efficiency determinations /
Author Steger, Joette Lee. ; Gergen, W. ; Margeson, J. H.
Other Authors
Author Title of a Work
Gergen, William.
CORP Author Radian Corp., Research Triangle Park, NC.;Environmental Monitoring Systems Lab., Research Triangle Park, NC.
Publisher U.S. Environmental Protection Agency, Environmental Monitoring Systems Laboratory,
Year Published 1988
Report Number EPA/600/4-88/017; EPA-68-02-4119
Stock Number PB88-204235
Subjects Ethylene oxide
Additional Subjects Ethylene oxide ; Oxygen heterocyclic compounds ; Chemical analysis ; Concentration(Composition) ; Air pollution sampling ; CAS registry no 75-21-8
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB88-204235 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 113 pages ; 28 cm
Abstract
Radian Corporation, assisting the Environmental Monitoring Systems Laboratory, Environmental Protection Agency, Research Triangle Park, North Carolina, performed a field evaluation of a method for sampling and analyzing ethylene oxide (EO) in the vent stream from a sterilization chamber and a dilute acid scrubber. The utility of the sampling method for measuring the efficiency of the control unit was also evaluated. The evaluated sampling and analysis procedure used semi-continuous direct sampling with on-line gas chromatographic analysis. Laboratory studies of the sampling method previous to the field test showed that semi-continuous direct sampling was capable of measuring EO emissions to within 11% of the expected value with a between-trial precision of 5 percent.
Notes
Caption title. "May 1988." "EPA/600/4-88/017." Microfiche.