Main Title |
Parameter Monitoring for Real-Time Electrostatic Precipitator Troubleshooting. |
Author |
Lawless, P. A. ;
Ensor, D. S. ;
Sparks, L. E. ;
|
CORP Author |
Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. ;Research Triangle Inst., Research Triangle Park, NC. |
Year Published |
1987 |
Report Number |
EPA/600/D-87/070; |
Stock Number |
PB87-179271 |
Additional Subjects |
Electrostatic precipitators ;
Particles ;
Mathematical models ;
Emissions ;
Monitors ;
Opacity ;
Absorptivity ;
Space charge ;
Electric corona ;
Reprints ;
Pollution control
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB87-179271 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
16p |
Abstract |
The paper discusses detailed numerical calculations of particle charge and extinction coefficient performed using current models. The results suggest that information about rapping reentrainment, back corona, and, possibly, sulfuric acid condensation can be gained from simultaneous outlet measurements of opacity and space charge. Some experimental observations based on semicontinuous measurements have confirmed these results in a general way and point to the use of the method as a precipitator diagnostic tool. |