Record Display for the EPA National Library Catalog

RECORD NUMBER: 11 OF 12

Main Title Guide to Clean and Efficient Operation of Coal-Stoker-Fired Boilers.
Author Langsjoen, P. L. ;
CORP Author KVB, Inc., Minneapolis, MN.;Department of Energy, Washington, DC.;American Boiler Manufacturers Association, Arlington, VA.;Industrial Environmental Research Lab., Research Triangle Park, NC.
Year Published 1981
Report Number KVB-4-15900-560; DOE-EF-77-C-01-2609; EPA-600/8-81-016;
Stock Number PB82-229782
Additional Subjects Boilers ; Stokers ; Air pollution control ; Performance evaluation ; Design criteria ; Industrial wastes ; Combustion products ; Guidelines ;
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=2000BE2G.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB82-229782 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 76p
Abstract
The report is a guide for those in charge of operating coal-stoker-fired boilers. It explains and illustrates the types of coal-fired stokers in operation today. It explains the combustion process in simple terms. It explains the various heat losses in stoker boilers. And, it discusses ways in which coal-stoker-fired boilers may be operated at peak efficiency and with minimum pollutant emissions. Included are step-by-step instructions for optimizing excess air levels. The guidelines are based on the findings of an extensive coal-stoker test program cofunded by the American Boiler Manufacturers Association (ABMA), the U.S. Department of Energy, and the U.S. Environmental Protection Agency.