Record Display for the EPA National Library Catalog

RECORD NUMBER: 4 OF 5

Main Title Monitoring Airborne Particulate Mass by Beta Absorption.
Author Krost, K. J. ; Sawicki, C. R. ; Bell., J. P. ;
CORP Author Environmental Sciences Research Lab., Research Triangle Park, N.C.
Year Published 1977
Report Number EPA/600/J-77/079;
Stock Number PB-278 338
Additional Subjects Particles ; Detectors ; Radiation measuring instruments ; Air pollution ; Design criteria ; Performance evaluation ; Absorption spectra ; Feasibility ; Samples ; Beta particles ; Carbon 14 ; Reprints ; Air pollution detection ; Beta detection
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB-278 338 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 24p
Abstract
A prototype airborne particulate mass monitor, using the principle of beta radiation absorption, has been fabricated and evaluated on airborne particulate matter. A detection sensitivity of 80 microgram/sq cm was attained. A series of samples were collected, and a comparison was made between the gravimetric and beta absorption results obtained on each sample. This study demonstrated the feasibility of fabricating a fully automated system for the collection and analysis of airborne particulate mass, using the principle of beta absorption attenuation. (Copyright (c) 1977 by Marcel Dekker, Inc.)