Record Display for the EPA National Library Catalog

RECORD NUMBER: 7 OF 19

Main Title Pollution prevention assessment for a printed circuit board plant /
Author Edwards, Harry W. ; Kostrzewa, M. F. ; Looby, G. P.
Other Authors
Author Title of a Work
Kostrzewa, Michael F.
Looby, Gwen P.
CORP Author Colorado State Univ., Fort Collins. Dept. of Mechanical Engineering. ;University City Science Center, Philadelphia, PA.;National Risk Management Research Lab., Cincinnati, OH.
Publisher U.S. Environmental Protection Agency, National Risk Management Research Laboratory,
Year Published 1995
Report Number EPA/600-S-95-020; EPA-R-819557; PB96115571
Stock Number PB96-115571
OCLC Number 33474113
Subjects Printed circuits industry--Waste disposal--Environmental aspects--United States
Additional Subjects Printed circuit boards ; Materials recovery ; Metals ; Ion exchange ; Electrowinning ; Pollution control ; Waste management ; Pollution abatement ; Waste treatment ; Waste disposal ; Industrial wastes ; Waste streams ; Hazardous materials ; Waste water treatment ; Cost benefit analysis ; Pollution prevention ; Waste minimization ; Waste reduction ; SIC 20-39
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=30003VK8.PDF
http://purl.access.gpo.gov/GPO/LPS35207
https://purl.fdlp.gov/GPO/LPS35207
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EHAM  EPA/600/S-95/020 Region 1 Library/Boston,MA 05/25/2016
EJBD  EPA 600-S-95-020 c.1-2 Headquarters Library/Washington,DC 04/08/2013
EJDD  EPA/600/S-95/020 Env Science Center Library/Ft Meade,MD 03/14/1997
ELBD ARCHIVE EPA 600-S-95-020 In Binder Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ELBD  EPA 600-S-95-020 AWBERC Library/Cincinnati,OH 04/25/1998
EMBD  EPA/600/S-95/020 NRMRL/GWERD Library/Ada,OK 12/28/2001
NTIS  PB96-115571 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 5 pages : illustrations ; 28 cm.
Abstract
The WMAC team at Colorado State University performed an assessment at a plant that manufactures printed circuit boards. The team's report, detailing findings and recommendations, indicated that the onsite ion-exchange treatment of metal-containing rinse water generates regenerant solutions that could be further treated by electrowinning to recover metals and to achieve significant cost savings.
Notes
Caption title. "September 1995." "EPA/600-S-95-020." Shipping list no.: 1996-0037-P.