Main Title |
Monitoring system for collection and analyses of ambient ethylene dichloride (EDC) levels in the urban atmosphere / |
Author |
Elfers, L. ;
Fusaro, G. ;
Khalifa, A.
|
Other Authors |
|
CORP Author |
PEDCo-Environmental, Inc., Cincinnati, OH.;Environmental Monitoring and Support Lab., Research Triangle Park, NC. |
Publisher |
Environmental Monitoring and Support Laboratory, Office of Research and Development, U.S. Environmental Protection Agency, |
Year Published |
1979 |
Report Number |
EPA-600/4-79-059; 68-02-2722; EPA-68-02-2722 |
Stock Number |
PB80-144819 |
OCLC Number |
32190428 |
Subjects |
Environmental monitoring ;
Ethylene dichloride--Environmental aspects
|
Additional Subjects |
Gas analysis ;
Chlorine organic compounds ;
Urban areas ;
Chemical analysis ;
Monitoring ;
Field tests ;
Gas chromatography ;
Mass spectroscopy ;
Laboratory equipment ;
Industrial hygiene ;
Air pollution ;
Ethylene/dichloro ;
Air pollution detection ;
Occupational safety and health
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJBD ARCHIVE |
EPA 600-4-79-059 |
|
Headquarters Library/Washington,DC |
04/14/2014 |
EJBD |
EPA 600-4-79-059 |
|
Headquarters Library/Washington,DC |
09/15/2014 |
EKBD |
EPA-600/4-79-059 |
|
Research Triangle Park Library/RTP, NC |
11/16/2016 |
ESAD |
EPA 600-4-79-059 |
|
Region 10 Library/Seattle,WA |
03/23/2010 |
NTIS |
PB80-144819 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
viii, 46 pages : illustrations, plans ; 28 cm. |
Abstract |
A method for the measurement of ambient levels of ethylene dichloride (EDC) was developed and field tested. A 24-hour integrated sample is taken with an activated charcoal tube, followed by desorption of the EDC with carbon disulfide. The carbon disulfide solution is then analyzed for EDC by separation on a gas chromatograph and detection with a mass spectrometer. Development of the method included the following area steps: Selection of gas chromatographic conditions and a detection system for separation and quantification of EDC; Determination of adsorption capacity of the charcoal tube for EDC; Evaluation of the desorption of EDC from adsorbents under dry and wet conditions; Evaluation of optimum sampling rates; Determination of total method efficiency; and, Evaluation of the method under field conditions by use of data from field studies. |
Notes |
"EPA-600/4-79-059." "September 1979." "This report was submitted in fulfillment of contract no. 68-02- 2722, assignments no. 7 and no. 12 by PEDCo Environmental, Inc. under the sponsorship of the Environmental Protection Agency." Includes bibliographical references. |