Record Display for the EPA National Library Catalog

RECORD NUMBER: 23 OF 61

Main Title Evaluation of Trace Organic Emissions from Refuse Thermal Processing Facilities.
Author Higgins, G. M. ;
CORP Author Systech Corp., Xenia, OH.;Environmental Protection Agency, Washington, DC. Office of Solid Waste.
Year Published 1982
Report Number EPA-68-01-6071;
Stock Number PB85-249258
Additional Subjects Dioxins ; Emissions ; Furans ; Air pollution ; Tests ; Samples ; Thermal facilities ; RDF ; PTMAX ; Dispersion modeling
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB85-249258 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 152p
Abstract
The report presents the results of testing, sampling and analysis of three resource recovery facilities burning municipal wastes for emissions of tetra chlorinated dioxins and furans in the flue gas. The stack emissions were analyzed by the EPA PTMAX dispersion model to determine maximum 1-hour ground level concentrations. A wide distribution of isomers were reported both for TCDDs and TCDFs. The most toxic 2378 TCDD isomer emissions from the stack ranged from 3.4 to 180 mg per ton of the fuel fired, while 2,378 TCDFs ranged from 22 to 1800 micrograms/ton.