Record Display for the EPA National Library Catalog

RECORD NUMBER: 18 OF 19

Main Title Removal of toxic metals in electroplating wash water by a Donnan dialysis process (final report) {MICROFICHE}
Author Hamil, Henry F.
CORP Author Southwest Research Inst., San Antonio, TX.;Industrial Environmental Research Lab.-Cincinnati, OH.
Publisher Environmental Protection Agency, Office of Research and Development, Industrial Environmental Research Laboratory ;
Year Published 1982
Report Number EPA-600/12-82-098
Stock Number PB83-148155
Subjects Toxic metals
Additional Subjects Water pollution control ; Electroplating ; Metals ; Ion exchanging ; Dialysis ; Laboratory equipment ; Copper ; Cadmium ; Zinc ; Donnan dialysis process
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB83-148155 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 39 p. : ill. ; 28 cm.
Abstract
A program was conducted to develop anion-exchange membranes to be used in the removal of copper, cadmium, and zinc, as their complex cyanide anions, from cyanide process electroplating wash waters by a Donnan dialysis process. For these laboratory studies, simulated wash waters prepared by diluting electroplating bath solutions to the desired metal content were utilized.
Notes
Prepared by Southwest Research Institute. Dec. 1982. Microfiche.