Main Title Trickling filter/solids contact performance with rock filters at high organic loadings /
Author Matasci, Raymond N. ; Clark, D. L. ; Heidman, J. A. ; Parker, D. S. ; Petrik, B.
Other Authors
Author Title of a Work
Matasci, Raymond N.
Clark, David L.
Heidman, James A.
Parker, Denny S.
Petrik, Bruce.
Richards, Darrel.
CORP Author Brown and Caldwell, Pleasant Hill, CA. ;Morro Bay, CA.;Environmental Protection Agency, Cincinnati, OH. Water Engineering Research Lab.
Publisher U.S. Environmental Protection Agency,
Year Published 1986
Report Number EPA/600-J-88-010; EPA-68-03-1818
Stock Number PB88-202445
OCLC Number 27882084
Subjects Trickling filters ; Sewage--Purification--Filtration
Additional Subjects Chemical removal(Water treatment) ; Waste water ; Concentration(Composition) ; Water pollution control
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=20013254.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJBD  EPA 600-J-88-010 Headquarters Library/Washington,DC 07/25/2013
ELBD ARCHIVE EPA 600-J-88-010 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ELBD RPS EPA 600-J-88-010 repository copy AWBERC Library/Cincinnati,OH 05/09/2016
NTIS  PB88-202445 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 20 pages : charts, plan ; 28 cm
Abstract
The performance of the trickling filter/solids contact (TF/SC) process at high organic loadings was studied at the Morro Bay-Cayucos treatment plant. The average secondary effluent TSS increased only slightly (from 13 mg/L to 15 mg/L) when the filter BOD5 loading was doubled from 480 g/cu m-day (30 ppd/1000 cu ft) to 960 g/cu m-days (60 ppd/1000 cu ft). The rock trickling filter operated without noticeable odors at the higher loading, although Beggiatoa presence indicated the filter was stressed. When the Morro Bay-Cayucos secondary process operated in the trickling filter mode at the lower filter loading, average secondary effluent TSS was 28 mg/L. Work at the Coeur d'Alene, Idaho, trickling filter plant showed that average secondary effluent TSS decreased from 25 mg/L to 16 mg/L when the old shallow secondary clarifier was replaced with a new flocculator-clarifier.
Notes
"Presented at the 59th annual conference of the Water Pollution Control Federation, October 9, 1986, Los Angeles, California." "EPA/600-J-88-010." "1986." Includes bibliographical references. EPA 600-J-88-010 per NSCEP's publication title list.