Record Display for the EPA National Library Catalog

RECORD NUMBER: 2 OF 3

Main Title Restoration of failing on-lot sewage disposal areas /
Other Authors
Author Title of a Work
Fritton, Daniel D.
Publisher U.S. Environmental Protection Agency, Municipal Environmental Research Laboratory : Center for Environmental Research Information [distributor],
Year Published 1984
Report Number EPA/600-S2-84-062
OCLC Number 10953701
Subjects Sewage disposal--Pennsylvania ; Septic tanks ; Water conservation--Pennsylvania
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=2000THQG.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJBD  EPA 600-S2-84-062 In Binder Headquarters Library/Washington,DC 09/06/2018
ELBD ARCHIVE EPA 600-S2-84-062 In Binder Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
Collation 3 pages : illustrations ; 28 cm
Notes
Caption title. At head of title: Project summary. Distributed to depository libraries in microfiche. "Apr. 1984." "EPA/600-S2-84-062."
Contents Notes
"Two techniques were evaluated for rehabilitating failing septic tank/soil absorption systems - water conservation and absorption bed resting. These techniques may offer less costly alternatives to complete replacement of the soil absorption area. Eleven homes with failing soil absorption areas were identified in the Centre County, Pennsylvania, region. At each home, the soil and site were characterized, and baseline data were collected on household water flow and septic tank effluent quality. Water conservation devices were then installed at one of three levels of predicted water reduction capability - maximum, moderate, or minimum. At three of the minimum water conservation homes, effluent was also diverted to a specially designed alternative trench for 10 months to permit the main absorption area to rest. After conservation measures were applied, water flow and effluent quality were measured for periods comparable with the baseline data collection period. In addition, the soil absorption areas were characterized by weekly measurements of surface conditions and effluent ponding levels for up to 2 years. Median in-house water use reductions were statistically significant and ranged from 9.8% to 42.5%. The water use reductions were in accord with the increased concentrations of most effluent quality parameters. Maximum levels of water conservation generally succeeded in restoring failing absorption beds, but lower levels of conservation did not. Absorption bed resting also restored failing systems. None of the three rested systems malfunctioned in the 16 months after effluent was redirected to them. However effluent was ponded in them, and the level continues to rise, suggesting that the effluent will have to be directed to the alternative trench at regular intervals."