Main Title Operating Experience with EPA's (Environmental Protection Agency's) Mobile Incineration System.
Author Gupta, G. D. ; Sawyer, R. ; Freestone, F. J. ;
CORP Author Enviresponse, Inc., Livingston, NJ.;Environmental Protection Agency, Cincinnati, OH. Hazardous Waste Engineering Research Lab.
Year Published 1988
Report Number EPA-68-03-3255; EPA/600/D-88/034;
Stock Number PB88-170428
Additional Subjects Incinerators ; Solid wastes ; Waste disposal ; Dioxin ; Mobile equipment ; US EPA
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB88-170428 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 28p
Abstract
The paper describes the recent modifications made to the U.S. Environmental Protection Agency's (EPA) Mobile Incineration System. These modifications were aimed toward increasing the capacity of the system as well as its on-stream factor. The operation of the modified system was resumed on June 1. 1987. During the three month period following that, various system performance tests were conducted. Besides these tests, over a million pounds of dioxin-contaminated lids and liquids including soil, plastics, trash, grass, tyvek, clothing, wood, etc. have been incinerated. A brief summary of the various test results and the highlights of the major problems encountered during the system operation, adopted solutions, and lessons learned are also presented in the paper.