Record Display for the EPA National Library Catalog

RECORD NUMBER: 1 OF 1

Main Title Pressure and vacuum sewer demonstration project Bend, Oregon /
Author Eblen, Jessie E., ; Clark, Lloyd K.
Other Authors
Author Title of a Work
Clark, Lloyd K.,
CORP Author Bend, OR. ;C and G Engineering, Inc., Salem, OR.;Municipal Environmental Research Lab., Cincinnati, OH.
Publisher Environmental Protection Agency, Office of Research and Development, Municipal Environmental Research Laboratory ; available through the National Technical Information Service,
Year Published 1978
Report Number EPA-600/2-78-166; EPA-S-803295
Stock Number PB-287 146
OCLC Number 04347354
Subjects Sewerage--Oregon--Bend ; Sewage disposal--Oregon--Bend ; Hydraulic engineering--Oregon--Bend
Additional Subjects Sewers ; Sanitary sewers ; Sewage pumps ; Urban areas ; Pressure ; Vacuum apparatus ; Performance evaluation ; Sump pumps ; Construction costs ; Maintenance ; Reliability ; Septic tanks ; Chemical properties ; Sewage ; Gravity ; Oregon ; Pressure sewers ; Vacuum sewers ; Bend(Oregon)
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=9101MO46.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJBD  EPA 600-2-78-166 Headquarters Library/Washington,DC 07/29/2013
ELBD ARCHIVE EPA 600-2-78-166 Received from HQ AWBERC Library/Cincinnati,OH 10/04/2023
ELBD RPS EPA 600-2-78-166 repository copy AWBERC Library/Cincinnati,OH 10/17/2014
ESAD  EPA 600-2-78-166 Region 10 Library/Seattle,WA 06/10/2005
NTIS  PB-287 146 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation ix, 113 pages : illustrations ; 28 cm.
Abstract
A pressure sewer system collecting domestic septic tank effluent and a vacuum system collecting raw domestic sewage were constructed in the City of Bend, Oregon. Each of the systems collected sewage from eleven houses and discharged into existing gravity sewer mains. Groups of one, two and three houses were served by single collection sump/vacuum valve or collection sump/pump combinations. The systems were operated and monitored for a period of approximately one year. The systems were evaluated for construction costs, operation and maintenance costs, reliability, operating characteristics, and chemical characteristics of collected sewage and septic effluent.
Notes
Includes bibliographical references (page 112). Submitted by C & G Engineering, Inc., Salem, Oregon, under grant no. Contract Number: S803295.