Main Title Paint Spray Booth Modifications for Recirculation Ventilation.
Author Darvin, C. H. ; Proffitt, D. ; Ayer, J. ;
CORP Author Acurex Corp., Research Triangle Park, NC. ;Air Quality Specialists, Newport Beach, CA.;Environmental Protection Agency, Research Triangle Park, NC. Air Pollution Prevention and Control Div.
Publisher 1997
Year Published 1997
Report Number EPA-68-D4-0111; EPA/600/A-97/048;
Stock Number PB97-195598
Additional Subjects Spray painting ; Paint applicators ; Air flow ; Spray coating ; Coating processes ; Ventilation ; Air circulation ; Flow rates ; Exhaust emissions ; Air pollution abatement ; Demonstration programs ; Paint booths ; Partitioned recirculation ; Volatile organic compounds ; Hazardous air pollutants ; Pollution prevention
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB97-195598 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 12p
Abstract
The paper gives results of a full-scale demonstration program in which paint booth exhaust flow rates were safely reduced from 137,000 to 43,000 cfm (65 to 20 cu m/sec). It discusses in detail the key engineering and safety issues included in the system evaluation and design efforts, and illustrates the viability of recirculation/partitioning for many industrial, aerospace, and military coating operations.