Main Title |
Compact, in-stack, three size cut particle classifier / |
Author |
Lacey, George E. ;
Cushing, Kenneth M. ;
Smith., Wallace B.
|
Other Authors |
|
CORP Author |
Southern Research Inst., Birmingham, Ala.;Environmental Sciences Research Lab., Research Triangle Park, N.C. |
Publisher |
Environmental Sciences Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency, |
Year Published |
1977 |
Report Number |
EPA-600/7-77-033; EPA-68-02-1736 |
Stock Number |
PB-268 238 |
OCLC Number |
53275635 |
Additional Subjects |
Classifers ;
Particle size distribution ;
Impactors ;
Electric power plants ;
Air pollution ;
Sampling ;
Design criteria ;
Chimneys ;
Combustion products ;
Industrial wastes ;
Aerosols ;
Calibrating ;
Performance evaluation ;
Field tests ;
Air pollution sampling ;
Stationary sources
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJBD |
EPA 600-7-77-033 |
c.1 |
Headquarters Library/Washington,DC |
02/04/2014 |
EKBD |
EPA-600/7-77-033 |
|
Research Triangle Park Library/RTP, NC |
10/24/2003 |
ELBD ARCHIVE |
EPA 600-7-77-033 |
Received from HQ |
AWBERC Library/Cincinnati,OH |
10/04/2023 |
ELBD RPS |
EPA 600-7-77-033 |
repository copy |
AWBERC Library/Cincinnati,OH |
10/17/2014 |
ESAD |
EPA 600-7-77-033 |
|
Region 10 Library/Seattle,WA |
03/23/2010 |
NTIS |
PB-268 238 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
x, 84 p. : ill., forms ; 28 cm. |
Abstract |
A compact, in-stack, three size cut particle classifier was designed, fabricated and tested. The classifer consists of a two-stage impactor and back-up filter designed to measure the particulate emissions from sources in three size ranges: greater than 3 micrometer, approximately 1-3 micrometer, greater than 1 micrometer. Three sets of jet plates (two jet plates per set) are included. Each set is designed for a different flow rate; however, all particle size cutpoints produce data in the three size ranges of interest. A choice of flow rates is desirable to allow reasonable sampling times at particulate emission sources with both high and low mass loadings. The classifier was calibrated in the laboratory with monodisperse aerosols from a vibrating orifice aerosol generator. In field tests at three power plants, particle size distribution by the classifier were compared to particle size distributions by Andersen and Brink samplers. With this compact sampling system, measurements of the three size fractions are possible over a wide range of test conditions. |
Notes |
Project Officer: Kenneth T. Knapp. Southern Research Institute "April 1977." Includes bibliographical references. "EPA-600/7-77-033." |