Record Display for the EPA National Library Catalog

RECORD NUMBER: 6 OF 6

Main Title Hydrocarbon continuous monitoring systems for hazardous waste incinerator emissions measurement /
Author Cone, Laurie. ; Logan, T. ; Rollins, R.
Other Authors
Author Title of a Work
Logan, Thomas J.
Roosevelt, Rollins.
CORP Author Entropy Environmentalists, Inc., Research Triangle Park, NC.;Environmental Protection Agency, Research Triangle Park, NC. Atmospheric Research and Exposure Assessment Lab.
Publisher Atmospheric Research and Exposure Assessment Laboratory, Office of Research and Development, U.S. Environmental Protection Agency,
Year Published 1991
Report Number EPA/600/D-91/124; EPA-68-02-4442
Stock Number PB91-213561
Subjects Air--Pollution--Measurement ; Environmental monitoring--United States
Additional Subjects Air pollution monitoring ; Incineration ; Waste disposal ; Hazardous materials ; Hydrocarbons ; Continuous sampling ; Performance evaluation ; Long term effects ; Heating ; Flame ionization ; Carbon monoxide ; Oxygen ; Combustion efficiency ; Experimental design ; Field tests
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB91-213561 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 22 pages ; 28 cm
Abstract
The U.S. Environmental Protection Agency has sponsored an extended laboratory and field evaluation of continuous emission monitoring systems available to measure hydrocarbon emissions from hazardous waste incinerators. Performance tests of calibration drift, calibration error, response time, and instrument sensitivity to various hydrocarbons were conducted during the laboratory evaluation and two six-week field tests. Comparisons were also made between hydrocarbon emissions as measured by heated and unheated sample delivery systems. Long-term measurement of hydrocarbon emissions using a heated sampling system and flame ionization detector has been difficult to achieve at hazardous waste incinerators. During this test program, it was demonstrated that it is possible to operate a heated hydrocarbon monitoring system continuously for extended time periods with no system repair or maintenance. A gas sampling system providing simultaneous carbon monoxide and oxygen emissions data was also operated during the field tests.
Notes
"Symposium proceedings." "EPA/600/D-91/124." Microfiche.