Main Title |
Field tests of industrial stoker coal-fired boilers for emissions control and efficiency improvement, site I / |
Author |
Langsjoen, Peter L. ;
Langsjoen, P. L. ;
Burlingame, J. O. ;
Gabrielson, J. E.
|
Other Authors |
|
CORP Author |
KVB, Inc., Minneapolis, MN.;Industrial Environmental Research Lab., Research Triangle Park, NC.;Department of Energy, Washington, DC. Div. of Power Systems.;American Boiler Manufacturers Association, Arlington, VA. |
Publisher |
The Branch ; U.S. Environmental Protection Agency, Industrial Environmental Research Laboratory ; National Technical Information Service [distributor], |
Year Published |
1980 |
Report Number |
EPA-600/7-80-136a; DOE-EF-77-C-01-2609 |
Stock Number |
PB80-212822 |
OCLC Number |
08549085 |
Subjects |
Coal-fired furnaces ;
Air--Pollution--United States--Measurement ;
Air--Pollution--Measurement
|
Additional Subjects |
Air pollution ;
Boilers ;
Stokers ;
Industrial heating ;
Field tests ;
Data ;
Flue gases ;
Combustion products ;
Oxygen ;
Carbon dioxide ;
Nitrogen oxides ;
Sulfur trioxide ;
Particle size distribution ;
Coal ;
Combustion ;
Efficiency ;
|
Internet Access |
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
EJBD ARCHIVE |
EPA 600-7-80-136a |
|
Headquarters Library/Washington,DC |
06/24/2013 |
EKBD |
EPA-600/7-80-136a |
|
Research Triangle Park Library/RTP, NC |
02/06/2004 |
ELBD ARCHIVE |
EPA 600-7-80-136a |
|
AWBERC Library/Cincinnati,OH |
12/15/2022 |
ESAD |
EPA 600-7-80-136a |
2 copies |
Region 10 Library/Seattle,WA |
06/01/2016 |
NTIS |
PB80-212822 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
v, 72 pages : illustrations ; 28 cm. |
Abstract |
The report gives results of field measurements made on a 70,000 lb steam/hr coal-fired overfeed stoker with traveling grate. The effects of various parameters on boiler emissions and efficiency were studied. Parameters include overfire air, excess oxygen, grate heat release, and coal properties. Measurements include O2, CO2, NO, SO2, SO3, uncontrolled particulate loading, particle size distribution of the uncontrolled flyash, and combustible content of the ash. In addition to test results and observations, the report describes the facility tested, coals fired, test equipment, and procedures. Uncontrolled particulate loading on this unit averaged 1.2 lb/million Btu at full load. Full-load NO emissions ranged from 0.2 to 0.4 lb/million Btu. |
Notes |
"KVB, Inc." "May 1980." "IAG/contract nos. IAG-D7-E681 (EPA), EF-77-C-01-2609 (DoE), program element no. EHE624." |