Main Title |
Development of sorbent injection criteria for sulfur oxides control from tangentially fired coal boilers : project summary / |
Author |
Koucky, R. W. ;
Marion, J. L. ;
Anderson, D. K.
|
Other Authors |
|
CORP Author |
Combustion Engineering, Inc., Windsor, CT.;Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab. |
Publisher |
U.S. Environmental Protection Agency, Air and Energy Engineering Research Laboratory, |
Year Published |
1988 |
Report Number |
EPA/600/7-88/013; EPA-68-02-4224 |
Stock Number |
PB88-238357 |
Subjects |
Sorbents ;
Flue gases--Desulfurization ;
Flue gases--Desulphurization
|
Additional Subjects |
Sulfur dioxide ;
Boilers ;
Coal ;
Design criteria ;
Research projects ;
Mathematical models ;
Sorbents ;
Air pollution control ;
Exhaust gases ;
Stationary sources
|
Holdings |
Library |
Call Number |
Additional Info |
Location |
Last Modified |
Checkout Status |
NTIS |
PB88-238357 |
Some EPA libraries have a fiche copy filed under the call number shown. |
|
07/26/2022 |
|
Collation |
334 pages ; 28 cm |
Abstract |
The report describes a program to develop design criteria for injecting dry sorbents into tangentially fired coal furnaces for the control of SOx emissions. The program included aerodynamic cold-flow testing and mathematical modeling of sorbent injection, demonstration testing of SOx emissions control in a 14.7 MW thermal (50 million Btu/hr) tangentially fired Boiler Simulation Facility (BSF), and development of recommendations for sorbent injection in a tangentially fired boiler demonstration of the process. The isothermal flow modeling led to development of sorbent injection systems for tangentially fired furnaces which provide high levels of sorbent dispersion. A sorbent dispersion mathematical modeling technique was developed to support flow modeling in identifying and optimizing sorbent injection locations and methods. A procedure was developed for specifying sorbent injection locations and methods for a full-scale demonstration of the sorbent injection process in a tangentially fired utility boiler. |
Notes |
Microfiche. |