Main Title Evaluation of a Prototype Burner for Combined NOx/SO2 Control.
Author Lisauskas, R. A. ; Itse, D. C. ; Masser, C. C. ; Abele, A. R. ;
CORP Author Riley Stoker Corp., Worcester, MA. ;Energy and Environmental Research Corp., Irvine, CA.;Environmental Protection Agency, Research Triangle Park, NC. Air and Energy Engineering Research Lab.
Year Published 1985
Report Number EPA-68-02-3913; EPA/600/D-85/065;
Stock Number PB85-191070
Additional Subjects Burners ; Air pollution control ; Nitrogen oxides ; Sulfur dioxide ; Pilot plants ; Combustion products ; Industrial wastes ; Sorbents ; Performance evaluation ; Low nitrogen oxides concentric firing systems
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB85-191070 Some EPA libraries have a fiche copy filed under the call number shown. 07/26/2022
Collation 27p
Abstract
The paper summarizes results of EPA-sponsored large pilot-scale combustion tests on a Riley Stoker second-generation low-NOx burner. Parametric tests were conducted on a single 29 MWt (100 million Btu/hr) prototype burner to determine conditions required for low-NOx operation and for combined NOx/SO2 control. SO2 reductions were evaluated for two sorbents, two injection locations, and three coals. NOx emissions of 150-250 ppm, corrected to 3% O2, were obtained under various combustion conditions. SO2 reductions of 31-57%, with no detrimental effect on NOx emissions, were observed.