Brief Records : EPA National Library Catalog

Items Found: 4

Showing Items: 1 - 4

Your Search: (SUBJECT=Federal Reference Method FRM)

OLS Field Name OLS Field Data
Full Record Document Number: 1
Main Title Data quality objectives (DQOs) for relating federal reference method (FRM) and continuous PM2.5 measurements to report an air quality index (AQI).
Author Eberly, S. ; Hanley, T. ; Weinstock, L. ; Fitz-Simons, T. ; Tamanini, T.
Other Authors
Author Title of a Work
Presnell, Vickie.
CORP Author Environmental Protection Agency, Research Triangle Park, NC. Office of Air Quality Planning and Standards. ;Battelle Memorial Inst., Arlington, VA.
Publisher U.S. Environmental Protection Agency, Office of Air and Radiation, Office of Air Quality Planning and Standards,
Year Published 2002
Report Number EPA-454/B-02-002; 68-D-98-030
Stock Number PB2003-103058
OCLC Number 51626840
Subjects Air--Pollution--United States--Measurement--Quality control. ; Air--Pollution--United States--Measurement--Statistics.
Additional Subjects Air pollution monitoring ; Guidelines ; Data collection ; Data sources ; Case studies ; Model development ; Decisions ; Inputs ; Study boundaries ; Measurements ; Linear regression ; Data Quality Objectives(DQOs) ; Federal Reference Method(FRM) ; Air Quality Index(AIR) ; Metropolitan Statistical Areas(MSAs) ; Particulate matter(PM) ; Ozone(O3) ; Carbon monoxide(CO) ; Sulfur dioxide(SO2) ; Nitrogen dioxide(NO2)
Internet Access
Description Access URL
http://www.epa.gov/ttn/amtic/files/ambient/monitorstrat/aqidqor2.pdf
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=P100D6RE.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
EJBD ARCHIVE EPA 454-B-02-002 Headquarters Library/Washington,DC 12/30/2013
EKBD  EPA-454/B-02-002 Research Triangle Park Library/RTP, NC 02/14/2003
NTIS  PB2003-103058 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. 01/01/1988
Collation 1 v. (various pagings) : ill. ; 28 cm.

Full Record Document Number: 2
Main Title Equating Semi-Continuous (SC) PM(sub 2.5) Mass Monitor Measurement Values with Federal Reference Method (FRM) PM(sub 2.5) Monitor Measurement Values.
Author L. Smith ; M. Porter ; M. Nysewander ; G. Glen ; C. Stallings
Other Authors
Author Title of a Work
E. S. Hall
CORP Author Alion Science and Technology, Norfolk, VA.; Environmental Protection Agency, Research Triangle Park, NC. Human Exposure and Atmospheric Sciences Div.
Year Published 2011
Report Number EPA/600/R-11/039; EP-D-05-065; NERL-RTP-HEASD-11-010
Stock Number PB2011-110916
Additional Subjects Air pollution monitoring ; Measurement values ; Human health ; Population ; Air quality monitoring ; Compliance ; Ambient concentration levels ; Health outcomes ; Filter collections ; Mass monitor measurement values ; Federal Reference Method(FRM) ; Particulate matter(PM) ; National Ambient Air Quality Standards(NAAQS) ; Environmental Protection Agency(EPA) ; Federal Equivalent Method(FEM) ; Semi-continuous(SC) ; National Exposure Research Laboratory(NERL)
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB2011-110916 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. 11/09/2011
Collation 442p

Full Record Document Number: 3
Main Title Evaluation of Field-Deployed Low Cost PM Sensors.
Author Williams, R. ; Kaufman, A. ; Hanley, T. ; Rice, J. ; Garvey, S.
CORP Author Environmental Protection Agency, Research Triangle Park, NC.; Oak Ridge Inst. for Science and Education, TN.
Year Published 2014
Report Number EPA/600/R-14/464
Stock Number PB2015-102104
Additional Subjects PM Sensors ; Air quality standards ; Environmental monitoring ; Pollutants ; Particulate Matter (PM) ; Federal Reference Method (FRM) ; Federal Equivalent Method (FEM) ; Air Climate & Energy (ACE)
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=P100L9WP.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB2015-102104 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. 10/02/2015
Collation 76p

Full Record Document Number: 4
Main Title Performance of the Proposed New Federal Reference Method for Measuring Ozone Concentrations in Ambient Air, Technical Report.
Author R. Long ; E. S. Hall ; M. Beaver ; R. M. Duvall ; S. Kaushik
CORP Author Environmental Protection Agency, Research Triangle Park, NC. National Exposure Research Lab.
Year Published 2014
Report Number EPA/600/R-14/432
Stock Number PB2015-101240
Additional Subjects Air pollution monitoring ; Ozone ; Chemiluminescence ; Ethylene ; Measurement ; Methodology ; Performance evaluation ; Regulations ; Sampling ; US EPA ; Federal Reference Method(FRM)
Internet Access
Description Access URL
https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=P100L9T6.PDF
Holdings
Library Call Number Additional Info Location Last
Modified
Checkout
Status
NTIS  PB2015-101240 Most EPA libraries have a fiche copy filed under the call number shown. Check with individual libraries about paper copy. 04/10/2015
Collation 32p