Simple Search Results

You found 27151 results. We have displayed only the first 1035 results in this view.

We suggest that you return to the search page and try a new search with more narrow search criteria,
or try a Detailed Search.


SCC 10100101
  External Combustion Boilers > Electric Generation > Anthracite Coal > Pulverized Coal
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- Formula Lb per Ton Anthracite Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100102
  External Combustion Boilers > Electric Generation > Anthracite Coal > Traveling Grate (Overfeed) Stoker
  POLLUTANT Arsenic NEI 7440382 CAS 7440-38-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.900E-4 Lb per Ton Anthracite Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100102
  External Combustion Boilers > Electric Generation > Anthracite Coal > Traveling Grate (Overfeed) Stoker
  POLLUTANT Chromium NEI 7440473 CAS 7440-47-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.800E-2 Lb per Ton Anthracite Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100102
  External Combustion Boilers > Electric Generation > Anthracite Coal > Traveling Grate (Overfeed) Stoker
  POLLUTANT Sulfur oxides (SOx) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Anthracite Burned;
Quality -- B    Emissions Factors Applicability

SCC 10100201
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Wet Bottom (Bituminous Coal)
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : SULFURIC ACID PLANT ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Arsenic NEI 7440382 CAS 7440-38-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.840E-4 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Beryllium NEI 7440417 CAS 7440-41-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.100E-5 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Ethylene dichloride NEI 107062 CAS 107-06-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.000E-5 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Heptachlorodibenzo-p-dioxins, total NEI 37871004 CAS
    Primary Control / Secondary Control : SULFURIC ACID PLANT ,
  Emission Factor -- 1.500E-3 mg per Megagram Coal Burned;
Quality -- U    Emissions Factors Applicability

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Heptachlorodibenzo-p-dioxins, total NEI 37871004 CAS
    Primary Control / Secondary Control : DUST SUPPRESSION BY WATER SPRAYS , DUCT SORBENT INJECTION ,
  Emission Factor -- 1.000E-8 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Heptachlorodibenzofurans, total NEI CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 7.680E-11 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Hexachlorodibenzo-p-dioxins, total NEI 34465468 CAS 34465-46-8
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.870E-11 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Manganese NEI 7439965 CAS 7439-96-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.280E-4 - 2.980E-3 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Manganese NEI 7439965 CAS 7439-96-5
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.900E-4 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Methyl ethyl ketone NEI 78933 CAS 78-93-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.900E-4 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.200E1 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability    Duplicate factor exists.

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Octachlorodibenzo-p-dioxins, total NEI 3268879 CAS 3268-87-9
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.160E-10 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Octachlorodibenzofurans, total NEI 39001020 CAS 39001-02-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 6.630E-11 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Tetrachlorodibenzofurans, total NEI CAS
    Primary Control / Secondary Control : DUST SUPPRESSION BY WATER SPRAYS , DUCT SORBENT INJECTION ,
  Emission Factor -- 2.490E-9 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100203
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Cyclone Furnace (Bituminous Coal)
  POLLUTANT Benzyl chloride NEI 100447 CAS 100-44-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 7.000E-4 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100203
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Cyclone Furnace (Bituminous Coal)
  POLLUTANT Mercury NEI 7439976 CAS 7439-97-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.600E-5 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability

SCC 10100203
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Cyclone Furnace (Bituminous Coal)
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10100203
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Cyclone Furnace (Bituminous Coal)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : SULFURIC ACID PLANT ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100204
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Spreader Stoker (Bituminous Coal)
  POLLUTANT Lead NEI 7439921 CAS 7439-92-1
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.070E-4 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability

SCC 10100204
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Spreader Stoker (Bituminous Coal)
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.000E-2 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10100204
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Spreader Stoker (Bituminous Coal)
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : FABRIC FILTER - LOW TEMPERATURE , I.E. T<180F ,
  Emission Factor -- 1.700E1 Lb per Ton Bituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10100204
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Spreader Stoker (Bituminous Coal)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : FABRIC FILTER - LOW TEMPERATURE , I.E. T<180F ,
  Emission Factor -- 1.200E1 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100212
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential) (Bituminous Coal)
  POLLUTANT Biphenyl NEI 92524 CAS 92-52-4
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.700E-6 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100212
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential) (Bituminous Coal)
  POLLUTANT Dioctyl phthalate NEI 117817 CAS 117-81-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 7.300E-5 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100212
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential) (Bituminous Coal)
  POLLUTANT Fluorene NEI 86737 CAS 86-73-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 9.100E-7 Lb per Ton Bituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10100212
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential) (Bituminous Coal)
  POLLUTANT Methyl methacrylate NEI 80626 CAS 80-62-6
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.000E-5 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100302
  External Combustion Boilers > Electric Generation > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : SECONDARY SEAL ON FLOATING ROOF TANK ,
  Emission Factor -- Formula Lb per Ton Lignite Burned;
Quality -- U    Emissions Factors Applicability

SCC 10100302
  External Combustion Boilers > Electric Generation > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Propionaldehyde NEI 123386 CAS 123-38-6
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.800E-4 Lb per Ton Lignite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100303
  External Combustion Boilers > Electric Generation > Lignite > Cyclone Furnace
  POLLUTANT Polycyclic organic matter (POM) NEI 246 CAS
    Primary Control / Secondary Control : SULFURIC ACID PLANT ,
  Emission Factor -- 1.100E-7 - 1.600E-6 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability

SCC 10100318
  External Combustion Boilers > Electric Generation > Lignite > Atmospheric Fluidized Bed Combustion - Circulating Bed
  POLLUTANT Chloroform NEI 67663 CAS 67-66-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 5.900E-5 Lb per Ton Lignite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100902
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood/Bark Fired Boiler
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : SECONDARY SEAL ON FLOATING ROOF TANK ,
  Emission Factor -- 6.500E-2 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10100215
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Cell Burner (Bituminous Coal)
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.650E-1 Lb per 1000 Tons Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100215
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Cell Burner (Bituminous Coal)
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : IMPINGEMENT PLATE SCRUBBER ,
  Emission Factor -- 6.300E-1 Lb per Ton Bituminous Coal Burned;
Quality -- C    Emissions Factors Applicability

SCC 10100215
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Cell Burner (Bituminous Coal)
  POLLUTANT Sulfur oxides (SOx) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100218
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Atmospheric Fluidized Bed Combustion: Circulating Bed (Bitum. Coal)
  POLLUTANT Benzene NEI 71432 CAS 71-43-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.300E-3 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100401
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 6 Oil: Normal Firing
  POLLUTANT Copper NEI CAS 7440-50-8
    Primary Control / Secondary Control : ULTRA LOW NOX BURNERS (ULNB) ,
  Emission Factor -- 1.180E-5 Lb per MMBtu Heat Input;
Quality -- U    Emissions Factors Applicability

SCC 10100401
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 6 Oil: Normal Firing
  POLLUTANT Ethylbenzene NEI 100414 CAS 100-41-4
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.360E-5 Lb per 1000 Gallons Residual Oil (No. 6) Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100505
  External Combustion Boilers > Electric Generation > Distillate Oil > Grade 4 Oil: Tangential Firing
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : SULFURIC ACID PLANT ,
  Emission Factor -- 1.900E0 Lb per 1000 Gallons Residual Oil Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100505
  External Combustion Boilers > Electric Generation > Distillate Oil > Grade 4 Oil: Tangential Firing
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : TRAY-TYPE GAS ABSORPTION COLUMN ,
  Emission Factor -- 1.524E0 Lb per 1000 Gallons Residual Oil Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100908
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Heptachlorodibenzofurans, total NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.400E-10 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10100218
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Atmospheric Fluidized Bed Combustion: Circulating Bed (Bitum. Coal)
  POLLUTANT Perchloroethylene NEI 127184 CAS 127-18-4
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.300E-5 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100222
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Acetophenone NEI 98862 CAS 98-86-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.500E-5 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100222
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Arsenic NEI 7440382 CAS 7440-38-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.100E-4 Lb per Ton Subbituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100222
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Cobalt NEI 7440484 CAS 7440-48-4
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.000E-4 Lb per Ton Subbituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100222
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Formaldehyde NEI 50000 CAS 50-00-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.400E-4 Lb per Ton Subbituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100222
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Heptachlorodibenzo-p-dioxins, total NEI 37871004 CAS
    Primary Control / Secondary Control : DUST SUPPRESSION BY WATER SPRAYS , DUCT SORBENT INJECTION ,
  Emission Factor -- 1.000E-8 Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100222
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Pentachlorodibenzo-p-dioxins, total NEI CAS
    Primary Control / Secondary Control : DUST SUPPRESSION BY WATER SPRAYS , DUCT SORBENT INJECTION ,
  Emission Factor -- 7.060E-10 Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100222
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Polychlorinated dibenzofurans, total NEI 136677106 CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.090E-9 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100223
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Cyclone Furnace (Subbituminous Coal)
  POLLUTANT Cyanide NEI 57125 CAS 57-12-5
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.500E-3 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100223
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Cyclone Furnace (Subbituminous Coal)
  POLLUTANT Octachlorodibenzofurans, total NEI 39001020 CAS 39001-02-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 6.630E-11 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100225
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Traveling Grate (Overfeed) Stoker (Subbituminous Coal)
  POLLUTANT Hydrogen chloride NEI 7647010 CAS 7647-01-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.200E0 Lb per Ton Subbituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10100226
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom Tangential (Subbituminous Coal)
  POLLUTANT Carbon sulfide NEI 75150 CAS 75-15-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.300E-4 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100226
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom Tangential (Subbituminous Coal)
  POLLUTANT Formaldehyde NEI 50000 CAS 50-00-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.400E-4 Lb per Ton Subbituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100226
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom Tangential (Subbituminous Coal)
  POLLUTANT Lead NEI 7439921 CAS 7439-92-1
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.200E-4 Lb per Ton Subbituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100226
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom Tangential (Subbituminous Coal)
  POLLUTANT Methyl methacrylate NEI 80626 CAS 80-62-6
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.000E-5 Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100226
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom Tangential (Subbituminous Coal)
  POLLUTANT Nitrous oxide NEI CAS 10024-97-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.000E-2 Lb per Ton Subbituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10100226
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom Tangential (Subbituminous Coal)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100235
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Cell Burner (Subbituminous Coal)
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E-1 Lb per Ton Subbituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100237
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Atmospheric Fluidized Bed Combustion: Bubbling Bed (Subbitum Coal)
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.800E1 Lb per Ton Subbituminous Coal Burned;
Quality -- U    Emissions Factors Applicability

SCC 10100237
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Atmospheric Fluidized Bed Combustion: Bubbling Bed (Subbitum Coal)
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.520E1 Lb per Ton Subbituminous Coal Burned;
Quality -- U    Emissions Factors Applicability

SCC 10100237
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Atmospheric Fluidized Bed Combustion: Bubbling Bed (Subbitum Coal)
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.660E1 Lb per Ton Subbituminous Coal Burned;
Quality -- U    Emissions Factors Applicability

SCC 10100238
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Atmospheric Fluidized Bed Combustion - Circulating Bed (Subbitum Coal)
  POLLUTANT Hexavalent Chromium NEI 18540299 CAS 18540-29-9
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 7.900E-5 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100238
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Atmospheric Fluidized Bed Combustion - Circulating Bed (Subbitum Coal)
  POLLUTANT Magnesium NEI CAS 7439-95-4
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.100E-2 Lb per Ton Subbituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100300
  External Combustion Boilers > Electric Generation > Lignite > Pulverized Coal: Wet Bottom
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : VENTURI SCRUBBER ,
  Emission Factor -- 3.100E-1 Lb per Ton Lignite Burned;
Quality -- C    Emissions Factors Applicability

SCC 10100301
  External Combustion Boilers > Electric Generation > Lignite > Pulverized Coal: Dry Bottom, Wall Fired
  POLLUTANT Benzofluoranthenes NEI 56832736 CAS 56832-73-6
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.100E-7 Lb per Ton Lignite Burned;
Quality -- B    Emissions Factors Applicability

SCC 10100301
  External Combustion Boilers > Electric Generation > Lignite > Pulverized Coal: Dry Bottom, Wall Fired
  POLLUTANT Beryllium NEI 7440417 CAS 7440-41-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.310E-4 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability

SCC 10100301
  External Combustion Boilers > Electric Generation > Lignite > Pulverized Coal: Dry Bottom, Wall Fired
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- Formula Lb per Ton Lignite Burned;
Quality -- C    Emissions Factors Applicability

SCC 10100302
  External Combustion Boilers > Electric Generation > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Antimony NEI 7440360 CAS 7440-36-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.800E-5 Lb per Ton Lignite Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100302
  External Combustion Boilers > Electric Generation > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Benzofluoranthenes NEI 56832736 CAS 56832-73-6
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.100E-7 Lb per Ton Lignite Burned;
Quality -- B    Emissions Factors Applicability

SCC 10100302
  External Combustion Boilers > Electric Generation > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Carbon dioxide NEI CO2 CAS 124-38-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Lignite Burned;
Quality -- C    Emissions Factors Applicability

SCC 10100302
  External Combustion Boilers > Electric Generation > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Ethyl chloride NEI 75003 CAS 75-00-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.200E-5 Lb per Ton Lignite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100302
  External Combustion Boilers > Electric Generation > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Manganese NEI 7439965 CAS 7439-96-5
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.900E-4 Lb per Ton Lignite Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100302
  External Combustion Boilers > Electric Generation > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Methyl ethyl ketone NEI 78933 CAS 78-93-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.900E-4 Lb per Ton Lignite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100302
  External Combustion Boilers > Electric Generation > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.000E-2 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability    Duplicate factor exists.

SCC 10100302
  External Combustion Boilers > Electric Generation > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Styrene NEI 100425 CAS 100-42-5
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.500E-5 Lb per Ton Lignite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100303
  External Combustion Boilers > Electric Generation > Lignite > Cyclone Furnace
  POLLUTANT Benzo(a)pyrene NEI 50328 CAS 50-32-8
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.800E-8 Lb per Ton Lignite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100303
  External Combustion Boilers > Electric Generation > Lignite > Cyclone Furnace
  POLLUTANT Benzyl chloride NEI 100447 CAS 100-44-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 7.000E-4 Lb per Ton Lignite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100303
  External Combustion Boilers > Electric Generation > Lignite > Cyclone Furnace
  POLLUTANT Magnesium NEI CAS 7439-95-4
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.100E-2 Lb per Ton Lignite Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100303
  External Combustion Boilers > Electric Generation > Lignite > Cyclone Furnace
  POLLUTANT Nickel NEI 7440020 CAS 7440-02-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.800E-4 Lb per Ton Lignite Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100306
  External Combustion Boilers > Electric Generation > Lignite > Spreader Stoker
  POLLUTANT Total non-methane organic compounds (TNMOC) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.000E-2 Lb per Ton Lignite Burned;
Quality -- C    Emissions Factors Applicability

SCC 10100318
  External Combustion Boilers > Electric Generation > Lignite > Atmospheric Fluidized Bed Combustion - Circulating Bed
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : IMPINGEMENT PLATE SCRUBBER ,
  Emission Factor -- 6.300E-1 Lb per Ton Lignite Burned;
Quality -- C    Emissions Factors Applicability

SCC 10100318
  External Combustion Boilers > Electric Generation > Lignite > Atmospheric Fluidized Bed Combustion - Circulating Bed
  POLLUTANT Lead NEI 7439921 CAS 7439-92-1
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.200E-4 Lb per Ton Lignite Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100318
  External Combustion Boilers > Electric Generation > Lignite > Atmospheric Fluidized Bed Combustion - Circulating Bed
  POLLUTANT Methyl ethyl ketone NEI 78933 CAS 78-93-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.900E-4 Lb per Ton Lignite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100318
  External Combustion Boilers > Electric Generation > Lignite > Atmospheric Fluidized Bed Combustion - Circulating Bed
  POLLUTANT Nitrous oxide NEI CAS 10024-97-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.500E0 Lb per Ton Lignite Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100318
  External Combustion Boilers > Electric Generation > Lignite > Atmospheric Fluidized Bed Combustion - Circulating Bed
  POLLUTANT Selenium NEI 7782492 CAS 7782-49-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.300E-3 Lb per Ton Lignite Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100401
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 6 Oil: Normal Firing
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E0 Lb per 1000 Gallons Residual Oil (No. 6) Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100401
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 6 Oil: Normal Firing
  POLLUTANT Formaldehyde NEI 50000 CAS 50-00-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.300E-2 Lb per 1000 Gallons Residual Oil (No. 6) Burned;
Quality -- C    Emissions Factors Applicability

SCC 10100401
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 6 Oil: Normal Firing
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : WET SCRUBBER - LOW EFFICIENCY ,
  Emission Factor -- 4.000E1 Lb per 1000 Gallons Residual Oil (No. 6) Burned;
Quality -- B    Emissions Factors Applicability

SCC 10100404
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 6 Oil: Tangential Firing
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.000E-1 Lb per 1000 Gallons Residual Oil (No. 6) Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100404
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 6 Oil: Tangential Firing
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : IMPINGEMENT PLATE SCRUBBER ,
  Emission Factor -- 2.900E0 Lb per 1000 Gallons Residual Oil (No. 6) Burned;
Quality -- C    Emissions Factors Applicability

SCC 10100404
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 6 Oil: Tangential Firing
  POLLUTANT Benzo(g,h,i)perylene NEI 191242 CAS 191-24-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.260E-6 Lb per 1000 Gallons Residual Oil (No. 6) Burned;
Quality -- C    Emissions Factors Applicability

SCC 10100404
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 6 Oil: Tangential Firing
  POLLUTANT Benzo(b+k)fluoranthene NEI 102 CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.480E-6 Lb per 1000 Gallons Residual Oil (No. 6) Burned;
Quality -- C    Emissions Factors Applicability

SCC 10100404
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 6 Oil: Tangential Firing
  POLLUTANT Chloride NEI CAS 16887-00-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.470E-1 Lb per 1000 Gallons Residual Oil (No. 6) Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100404
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 6 Oil: Tangential Firing
  POLLUTANT Chromium NEI 7440473 CAS 7440-47-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.450E-4 Lb per 1000 Gallons Residual Oil (No. 6) Burned;
Quality -- C    Emissions Factors Applicability

SCC 10100404
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 6 Oil: Tangential Firing
  POLLUTANT Fluoranthene NEI 206440 CAS 206-44-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.840E-6 Lb per 1000 Gallons Residual Oil (No. 6) Burned;
Quality -- C    Emissions Factors Applicability

SCC 10100404
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 6 Oil: Tangential Firing
  POLLUTANT Fluoride NEI CAS 16984-48-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.730E-2 Lb per 1000 Gallons Residual Oil (No. 6) Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100405
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 5 Oil: Normal Firing
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : VENTURI SCRUBBER ,
  Emission Factor -- 1.400E0 Lb per 1000 Gallons Residual Oil (No. 5) Burned;
Quality -- C    Emissions Factors Applicability

SCC 10100405
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 5 Oil: Normal Firing
  POLLUTANT Methane NEI CAS 74-82-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.800E-1 Lb per 1000 Gallons Residual Oil (No. 5) Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100406
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 5 Oil: Tangential Firing
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.000E-1 Lb per 1000 Gallons Residual Oil (No. 5) Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100406
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 5 Oil: Tangential Firing
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per 1000 Gallons Residual Oil Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100406
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 5 Oil: Tangential Firing
  POLLUTANT Sulfur trioxide NEI CAS 7446-11-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per 1000 Gallons Residual Oil (No. 5) Burned;
Quality -- C    Emissions Factors Applicability

SCC 10100501
  External Combustion Boilers > Electric Generation > Distillate Oil > Grades 1 and 2 Oil
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : WET SCRUBBER - LOW EFFICIENCY , ULTRA LOW NOX BURNERS (ULNB) ,
  Emission Factor -- 5.000E0 Lb per 1000 Gallons Distillate Oil (No. 1 & 2) Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100501
  External Combustion Boilers > Electric Generation > Distillate Oil > Grades 1 and 2 Oil
  POLLUTANT Formaldehyde NEI 50000 CAS 50-00-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.500E-2 - 6.100E-2 Lb per 1000 Gallons Distillate Oil (No. 1 & 2) Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100501
  External Combustion Boilers > Electric Generation > Distillate Oil > Grades 1 and 2 Oil
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : WET SCRUBBER - LOW EFFICIENCY , ULTRA LOW NOX BURNERS (ULNB) ,
  Emission Factor -- 1.550E0 Lb per 1000 Gallons Distillate Oil (No. 1 & 2) Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100501
  External Combustion Boilers > Electric Generation > Distillate Oil > Grades 1 and 2 Oil
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.000E-1 Lb per 1000 Gallons Distillate Oil (No. 1 & 2) Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100504
  External Combustion Boilers > Electric Generation > Distillate Oil > Grade 4 Oil: Normal Firing
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : TRAY-TYPE GAS ABSORPTION COLUMN ,
  Emission Factor -- Formula Lb per 1000 Gallons Residual Oil Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100504
  External Combustion Boilers > Electric Generation > Distillate Oil > Grade 4 Oil: Normal Firing
  POLLUTANT Total non-methane organic compounds (TNMOC) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.600E-1 Lb per 1000 Gallons Distillate Oil (No. 4) Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100505
  External Combustion Boilers > Electric Generation > Distillate Oil > Grade 4 Oil: Tangential Firing
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.200E1 Lb per 1000 Gallons Distillate Oil (No. 4) Burned;
Quality -- B    Emissions Factors Applicability

SCC 10100505
  External Combustion Boilers > Electric Generation > Distillate Oil > Grade 4 Oil: Tangential Firing
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : TRAY-TYPE GAS ABSORPTION COLUMN ,
  Emission Factor -- 1.500E0 Lb per 1000 Gallons Residual Oil Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100505
  External Combustion Boilers > Electric Generation > Distillate Oil > Grade 4 Oil: Tangential Firing
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E0 Lb per 1000 Gallons Residual Oil Burned;
Quality -- C    Emissions Factors Applicability

SCC 10100601
  External Combustion Boilers > Electric Generation > Natural Gas > Boilers > 100 Million Btu/hr except Tangential
  POLLUTANT Anthracene NEI 120127 CAS 120-12-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- <2.400E-6 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100601
  External Combustion Boilers > Electric Generation > Natural Gas > Boilers > 100 Million Btu/hr except Tangential
  POLLUTANT N-Pentane NEI CAS 109-66-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.600E0 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100601
  External Combustion Boilers > Electric Generation > Natural Gas > Boilers > 100 Million Btu/hr except Tangential
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : WET SCRUBBER - LOW EFFICIENCY ,
  Emission Factor -- 1.400E2 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100601
  External Combustion Boilers > Electric Generation > Natural Gas > Boilers > 100 Million Btu/hr except Tangential
  POLLUTANT PM, primary NEI PM-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.600E0 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100602
  External Combustion Boilers > Electric Generation > Natural Gas > Boilers < 100 Million Btu/hr except Tangential
  POLLUTANT Benzo(a)pyrene NEI 50328 CAS 50-32-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- <1.200E-6 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100602
  External Combustion Boilers > Electric Generation > Natural Gas > Boilers < 100 Million Btu/hr except Tangential
  POLLUTANT Fluorene NEI 86737 CAS 86-73-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.800E-6 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- E    Emissions Factors Applicability

SCC 10100602
  External Combustion Boilers > Electric Generation > Natural Gas > Boilers < 100 Million Btu/hr except Tangential
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.600E0 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100604
  External Combustion Boilers > Electric Generation > Natural Gas > Tangentially Fired Units
  POLLUTANT 2-Methyl Naphthalene NEI 91576 CAS 91-57-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.400E-5 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100604
  External Combustion Boilers > Electric Generation > Natural Gas > Tangentially Fired Units
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.700E0 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100604
  External Combustion Boilers > Electric Generation > Natural Gas > Tangentially Fired Units
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.600E0 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100604
  External Combustion Boilers > Electric Generation > Natural Gas > Tangentially Fired Units
  POLLUTANT Toluene NEI 108883 CAS 108-88-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.400E-3 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- C    Emissions Factors Applicability

SCC 10100701
  External Combustion Boilers > Electric Generation > Process Gas > Boilers > 100 Million Btu/hr
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.000E0 Lb per Million Cubic Feet Process Gas Burned;
Quality -- U    Emissions Factors Applicability

SCC 10100801
  External Combustion Boilers > Electric Generation > Petroleum Coke > All Boiler Sizes
  POLLUTANT Beryllium NEI 7440417 CAS 7440-41-7
    Primary Control / Secondary Control : ROTOCLONE , MIST ELIMINATOR - HIGH EFFICIENCY ,
  Emission Factor -- 1.710E-5 Lb per MMBtu Heat Input;
Quality -- U    Emissions Factors Applicability

SCC 10100801
  External Combustion Boilers > Electric Generation > Petroleum Coke > All Boiler Sizes
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E-1 Lb per Ton Coke Burned;
Quality -- A    Emissions Factors Applicability

SCC 10100801
  External Combustion Boilers > Electric Generation > Petroleum Coke > All Boiler Sizes
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : ROTOCLONE , MIST ELIMINATOR - HIGH EFFICIENCY ,
  Emission Factor -- 6.105E-5 Lb per MMBtu Heat Input;
Quality -- U    Emissions Factors Applicability

SCC 10100901
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Antimony NEI 7440360 CAS 7440-36-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.900E-6 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10100901
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Carbon tetrachloride NEI 56235 CAS 56-23-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.500E-5 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10100901
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Fluorene NEI 86737 CAS 86-73-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.400E-6 Lb per MMBtu Heat Input;
Quality -- A    Emissions Factors Applicability

SCC 10100901
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Octachlorodibenzo-p-dioxins, total NEI 3268879 CAS 3268-87-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.600E-8 Lb per MMBtu Heat Input;
Quality -- B    Emissions Factors Applicability

SCC 10100901
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Phenol NEI 108952 CAS 108-95-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.100E-5 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10100901
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CENTRIFUGAL COLLECTOR (CYCLONE) - MEDIUM EFFICIENCY ,
  Emission Factor -- 4.900E-1 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10100902
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood/Bark Fired Boiler
  POLLUTANT 2-Chloronaphthalene NEI 91587 CAS 91-58-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.400E-9 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10100902
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood/Bark Fired Boiler
  POLLUTANT Cobalt NEI 7440484 CAS 7440-48-4
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.500E-6 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10100902
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood/Bark Fired Boiler
  POLLUTANT Ethylene dichloride NEI 107062 CAS 107-06-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.900E-5 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10100902
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood/Bark Fired Boiler
  POLLUTANT Naphthalene NEI 91203 CAS 91-20-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 9.700E-5 Lb per MMBtu Heat Input;
Quality -- A    Emissions Factors Applicability

SCC 10100902
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood/Bark Fired Boiler
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : SECONDARY SEAL ON FLOATING ROOF TANK ,
  Emission Factor -- 6.500E-2 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10100903
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Benzo(g,h,i)perylene NEI 191242 CAS 191-24-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 9.300E-8 Lb per MMBtu Heat Input;
Quality -- B    Emissions Factors Applicability

SCC 10200202
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200203
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Cyclone Furnace
  POLLUTANT Beryllium NEI 7440417 CAS 7440-41-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- < 8.100E-5 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability

SCC 10200225
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Traveling Grate (Overfeed) Stoker (Subbituminous Coal)
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : WATER SPRAYS ,
  Emission Factor -- 4.600E0 Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200904
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Hexavalent Chromium NEI 18540299 CAS 18540-29-9
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.600E-5 Lb per Ton Bark Burned;
Quality -- D    Emissions Factors Applicability

SCC 10100903
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Dichlorobiphenyl NEI CAS 25512-42-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.400E-10 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10100903
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Formaldehyde NEI 50000 CAS 50-00-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.400E-3 Lb per MMBtu Heat Input;
Quality -- A    Emissions Factors Applicability

SCC 10100903
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT 2,3,7,8-Tetrachlorodibenzofuran NEI 51207319 CAS 51207-31-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 9.000E-11 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10100903
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Toluene NEI 108883 CAS 108-88-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 9.200E-4 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10100903
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT 2,4,6-Trichlorophenol NEI 88062 CAS 88-06-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- < 2.200E-8 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10100908
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Chlorine NEI 7782505 CAS 7782-50-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.900E-4 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10100908
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Chlorobenzene NEI 108907 CAS 108-90-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.300E-5 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10100908
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Copper NEI CAS 7440-50-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.900E-5 Lb per MMBtu Heat Input;
Quality -- A    Emissions Factors Applicability

SCC 10100908
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Dichlorobiphenyl NEI CAS 25512-42-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.400E-10 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10100908
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Phosphorus (yellow or white) NEI 7723140 CAS 7723-14-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.700E-5 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10100908
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.700E-2 Lb per MMBtu Heat Input;
Quality -- A    Emissions Factors Applicability

SCC 10100908
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : SULFURIC ACID PLANT ,
  Emission Factor -- 4.000E-2 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10100908
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Tetrachlorobiphenyls, total NEI CAS 26914-33-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.500E-9 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10100908
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT o-Xylene NEI 95476 CAS 95-47-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.500E-5 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10100911
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Stoker boilers **
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.360E1 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability

SCC 10100911
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Stoker boilers **
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.500E0 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability

SCC 10101101
  External Combustion Boilers > Electric Generation > Bagasse > All Boiler Sizes
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : SECONDARY SEAL ON FLOATING ROOF TANK ,
  Emission Factor -- 1.360E0 Lb per Ton Bagasse Burned;
Quality -- D    Emissions Factors Applicability

SCC 10101302
  External Combustion Boilers > Electric Generation > Liquid Waste > Waste Oil
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per 1000 Gallons Waste Oil Burned;
Quality -- C    Emissions Factors Applicability

SCC 10200101
  External Combustion Boilers > Industrial > Anthracite Coal > Pulverized Coal
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- Formula Lb per Ton Anthracite Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200104
  External Combustion Boilers > Industrial > Anthracite Coal > Traveling Grate (Overfeed) Stoker
  POLLUTANT Beryllium NEI 7440417 CAS 7440-41-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.100E-4 Lb per Ton Anthracite Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200104
  External Combustion Boilers > Industrial > Anthracite Coal > Traveling Grate (Overfeed) Stoker
  POLLUTANT PM, primary NEI PM-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Anthracite Burned;
Quality -- C    Emissions Factors Applicability

SCC 10200104
  External Combustion Boilers > Industrial > Anthracite Coal > Traveling Grate (Overfeed) Stoker
  POLLUTANT Total organic compounds (TOC) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.000E-1 Lb per Ton Anthracite Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200202
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom
  POLLUTANT Acetophenone NEI 98862 CAS 98-86-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.500E-5 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200202
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : VENTURI SCRUBBER ,
  Emission Factor -- 3.100E-1 Lb per Ton Bituminous Coal Burned;
Quality -- C    Emissions Factors Applicability

SCC 10200202
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom
  POLLUTANT Chromium NEI 7440473 CAS 7440-47-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.600E-4 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10200202
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom
  POLLUTANT Dichloromethane NEI 75092 CAS 75-09-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.900E-4 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200202
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom
  POLLUTANT Dimethyl sulfate NEI 77781 CAS 77-78-1
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.800E-5 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200202
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom
  POLLUTANT Dioctyl phthalate NEI 117817 CAS 117-81-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 7.300E-5 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200202
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom
  POLLUTANT Fluoranthene NEI 206440 CAS 206-44-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 7.100E-7 Lb per Ton Bituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200202
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom
  POLLUTANT Isopropylbenzene NEI 98828 CAS 98-82-8
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 5.300E-6 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200202
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom
  POLLUTANT Mercury NEI 7439976 CAS 7439-97-6
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 8.300E-5 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10200202
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : SULFURIC ACID PLANT ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200202
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : TRAY-TYPE GAS ABSORPTION COLUMN ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200202
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom
  POLLUTANT Polychlorinated dibenzo-p-dioxins, total NEI 136677093 CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 6.660E-10 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200202
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom
  POLLUTANT Polychlorinated dibenzo-p-dioxins, total NEI 136677093 CAS
    Primary Control / Secondary Control : DUST SUPPRESSION BY WATER SPRAYS , DUCT SORBENT INJECTION ,
  Emission Factor -- 4.280E-8 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200202
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom
  POLLUTANT Selenium NEI 7782492 CAS 7782-49-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.300E-3 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10200202
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom
  POLLUTANT Tetrachlorodibenzo-p-dioxins, total NEI CAS
    Primary Control / Secondary Control : DUST SUPPRESSION BY WATER SPRAYS , DUCT SORBENT INJECTION ,
  Emission Factor -- 3.930E-10 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200203
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Cyclone Furnace
  POLLUTANT Ethylene dibromide NEI 106934 CAS 106-93-4
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.200E-6 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200203
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Cyclone Furnace
  POLLUTANT Methane NEI CAS 74-82-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.000E-2 Lb per Ton Bituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200203
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Cyclone Furnace
  POLLUTANT Propionaldehyde NEI 123386 CAS 123-38-6
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.800E-4 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200203
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Cyclone Furnace
  POLLUTANT Selenium NEI 7782492 CAS 7782-49-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.300E-3 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10200203
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Cyclone Furnace
  POLLUTANT 1,1,1-Trichloroethane NEI 71556 CAS 71-55-6
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.000E-5 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200204
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Spreader Stoker
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.650E-1 Lb per 1000 Tons Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200204
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Spreader Stoker
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CATALYTIC AFTERBURNER ,
  Emission Factor -- 1.200E1 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10200204
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Spreader Stoker
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : SULFURIC ACID PLANT ,
  Emission Factor -- 4.800E-1 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200205
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Overfeed Stoker
  POLLUTANT Hydrogen fluoride NEI 7664393 CAS 7664-39-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.500E-1 Lb per Ton Bituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200205
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Overfeed Stoker
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.200E0 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200212
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential)
  POLLUTANT Benzo(a)pyrene NEI 50328 CAS 50-32-8
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.800E-8 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200212
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential)
  POLLUTANT Chromium NEI 7440473 CAS 7440-47-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.600E-4 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10200223
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Cyclone Furnace (Subbituminous Coal)
  POLLUTANT Selenium NEI 7782492 CAS 7782-49-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.300E-3 Lb per Ton Subbituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10200302
  External Combustion Boilers > Industrial > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E-1 Lb per Ton Lignite Burned;
Quality -- A    Emissions Factors Applicability

SCC 10200302
  External Combustion Boilers > Industrial > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Hexavalent Chromium NEI 18540299 CAS 18540-29-9
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 7.900E-5 Lb per Ton Lignite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200602
  External Combustion Boilers > Industrial > Natural Gas > 10-100 Million Btu/hr
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.000E2 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200799
  External Combustion Boilers > Industrial > Process Gas > Other: Specify in Comments
  POLLUTANT Lead NEI 7439921 CAS 7439-92-1
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.660E-6 Lb per MMBtu Heat Input;
Quality -- U    Emissions Factors Applicability

SCC 10200212
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential)
  POLLUTANT Isopropylbenzene NEI 98828 CAS 98-82-8
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 5.300E-6 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200212
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential)
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.000E1 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability    Duplicate factor exists.

SCC 10200212
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential)
  POLLUTANT Pyrene NEI 129000 CAS 129-00-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.300E-7 Lb per Ton Bituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200213
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Wet Slurry
  POLLUTANT Beryllium NEI 7440417 CAS 7440-41-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.024E-4 Lb per MMBtu Heat Input;
Quality -- U    Emissions Factors Applicability

SCC 10200213
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Wet Slurry
  POLLUTANT Selenium NEI 7782492 CAS 7782-49-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.187E-5 Lb per MMBtu Heat Input;
Quality -- U    Emissions Factors Applicability

SCC 10200218
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Atmospheric Fluidized Bed Combustion: Circulating Bed (Bitum. Coal)
  POLLUTANT Bromoform NEI 75252 CAS 75-25-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.900E-5 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200218
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Atmospheric Fluidized Bed Combustion: Circulating Bed (Bitum. Coal)
  POLLUTANT Cadmium NEI 7440439 CAS 7440-43-9
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 5.100E-5 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10200218
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Atmospheric Fluidized Bed Combustion: Circulating Bed (Bitum. Coal)
  POLLUTANT Chlorobenzene NEI 108907 CAS 108-90-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.200E-5 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200218
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Atmospheric Fluidized Bed Combustion: Circulating Bed (Bitum. Coal)
  POLLUTANT Methyl methacrylate NEI 80626 CAS 80-62-6
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.000E-5 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200218
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Atmospheric Fluidized Bed Combustion: Circulating Bed (Bitum. Coal)
  POLLUTANT Selenium NEI 7782492 CAS 7782-49-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.300E-3 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10200221
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Wet Bottom (Subbituminous Coal)
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Subbituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200222
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : VENTURI SCRUBBER ,
  Emission Factor -- 3.100E-1 Lb per Ton Subbituminous Coal Burned;
Quality -- C    Emissions Factors Applicability

SCC 10200222
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Beryllium NEI 7440417 CAS 7440-41-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.100E-5 Lb per Ton Subbituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10200222
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Heptachlorodibenzo-p-dioxins, total NEI 37871004 CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 8.340E-11 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200222
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Hexachlorodibenzo-p-dioxins, total NEI 34465468 CAS 34465-46-8
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.870E-11 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200222
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.400E0 Lb per Ton Subbituminous Coal Burned;
Quality -- A    Emissions Factors Applicability    Duplicate factor exists.

SCC 10200222
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Pentachlorodibenzo-p-dioxins, total NEI CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.470E-11 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200222
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Perchloroethylene NEI 127184 CAS 127-18-4
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.300E-5 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200222
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Subbituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200222
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Total non-methane organic compounds (TNMOC) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E-2 Lb per Ton Subbituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200223
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Cyclone Furnace (Subbituminous Coal)
  POLLUTANT Benzofluoranthenes NEI 56832736 CAS 56832-73-6
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.100E-7 Lb per Ton Subbituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200223
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Cyclone Furnace (Subbituminous Coal)
  POLLUTANT Hexachlorodibenzofurans, total NEI CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.920E-10 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200223
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Cyclone Furnace (Subbituminous Coal)
  POLLUTANT Magnesium NEI CAS 7439-95-4
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.100E-2 Lb per Ton Subbituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10200223
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Cyclone Furnace (Subbituminous Coal)
  POLLUTANT 5-Methyl Chrysene NEI 3697243 CAS 3697-24-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.200E-8 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200223
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Cyclone Furnace (Subbituminous Coal)
  POLLUTANT Tetrachlorodibenzofurans, total NEI CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.040E-10 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200223
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Cyclone Furnace (Subbituminous Coal)
  POLLUTANT Vinyl acetate NEI 108054 CAS 108-05-4
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 7.600E-6 Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200224
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Spreader Stoker (Subbituminous Coal)
  POLLUTANT Chromium NEI 7440473 CAS 7440-47-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 9.420E-4 - 1.570E-3 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability

SCC 10200224
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Spreader Stoker (Subbituminous Coal)
  POLLUTANT Formaldehyde NEI 50000 CAS 50-00-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.210E-4 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability

SCC 10200224
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Spreader Stoker (Subbituminous Coal)
  POLLUTANT Nitrous oxide NEI CAS 10024-97-2
    Primary Control / Secondary Control : CATALYTIC AFTERBURNER ,
  Emission Factor -- 4.000E-2 Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200225
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Traveling Grate (Overfeed) Stoker (Subbituminous Coal)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : WATER SPRAYS ,
  Emission Factor -- 5.000E0 Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200226
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom Tangential (Subbituminous Coal)
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.650E-1 Lb per 1000 Tons Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200226
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom Tangential (Subbituminous Coal)
  POLLUTANT Dimethyl sulfate NEI 77781 CAS 77-78-1
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.800E-5 Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200226
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom Tangential (Subbituminous Coal)
  POLLUTANT Lead NEI 7439921 CAS 7439-92-1
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.200E-4 Lb per Ton Subbituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10200226
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom Tangential (Subbituminous Coal)
  POLLUTANT Phenol NEI 108952 CAS 108-95-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.600E-5 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200229
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Cogeneration (Subbituminous Coal)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200301
  External Combustion Boilers > Industrial > Lignite > Pulverized Coal: Dry Bottom, Wall Fired
  POLLUTANT Acrolein NEI 107028 CAS 107-02-8
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.900E-4 Lb per Ton Lignite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200301
  External Combustion Boilers > Industrial > Lignite > Pulverized Coal: Dry Bottom, Wall Fired
  POLLUTANT 2,4-Dinitrotoluene NEI 121142 CAS 121-14-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.800E-7 Lb per Ton Lignite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200301
  External Combustion Boilers > Industrial > Lignite > Pulverized Coal: Dry Bottom, Wall Fired
  POLLUTANT Fluorene NEI 86737 CAS 86-73-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 9.100E-7 Lb per Ton Lignite Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200301
  External Combustion Boilers > Industrial > Lignite > Pulverized Coal: Dry Bottom, Wall Fired
  POLLUTANT N-Hexane NEI 110543 CAS 110-54-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 6.700E-5 Lb per Ton Lignite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200301
  External Combustion Boilers > Industrial > Lignite > Pulverized Coal: Dry Bottom, Wall Fired
  POLLUTANT Selenium NEI 7782492 CAS 7782-49-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.300E-3 Lb per Ton Lignite Burned;
Quality -- A    Emissions Factors Applicability

SCC 10200302
  External Combustion Boilers > Industrial > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Dichloromethane NEI 75092 CAS 75-09-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.900E-4 Lb per Ton Lignite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200302
  External Combustion Boilers > Industrial > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Methyl hydrazine NEI 60344 CAS 60-34-4
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.700E-4 Lb per Ton Lignite Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200302
  External Combustion Boilers > Industrial > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Pyrene NEI 129000 CAS 129-00-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.300E-7 Lb per Ton Lignite Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200303
  External Combustion Boilers > Industrial > Lignite > Cyclone Furnace
  POLLUTANT Acenaphthene NEI 83329 CAS 83-32-9
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 5.100E-7 Lb per Ton Lignite Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200303
  External Combustion Boilers > Industrial > Lignite > Cyclone Furnace
  POLLUTANT Acetophenone NEI 98862 CAS 98-86-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.500E-5 Lb per Ton Lignite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200303
  External Combustion Boilers > Industrial > Lignite > Cyclone Furnace
  POLLUTANT Benzyl chloride NEI 100447 CAS 100-44-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 7.000E-4 Lb per Ton Lignite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200303
  External Combustion Boilers > Industrial > Lignite > Cyclone Furnace
  POLLUTANT Beryllium NEI 7440417 CAS 7440-41-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.100E-5 Lb per Ton Lignite Burned;
Quality -- A    Emissions Factors Applicability

SCC 10200303
  External Combustion Boilers > Industrial > Lignite > Cyclone Furnace
  POLLUTANT Ethyl chloride NEI 75003 CAS 75-00-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.200E-5 Lb per Ton Lignite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200304
  External Combustion Boilers > Industrial > Lignite > Traveling Grate (Overfeed) Stoker
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Lignite Burned;
Quality -- U    Emissions Factors Applicability

SCC 10200307
  External Combustion Boilers > Industrial > Lignite > Cogeneration
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Lignite Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200401
  External Combustion Boilers > Industrial > Residual Oil > Grade 6 Oil
  POLLUTANT Total non-methane organic compounds (TNMOC) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.800E-1 Lb per 1000 Gallons Residual Oil (No. 6) Burned;
Quality -- A    Emissions Factors Applicability

SCC 10200402
  External Combustion Boilers > Industrial > Residual Oil > 10-100 Million Btu/hr **
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per 1000 Gallons Residual Oil Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200404
  External Combustion Boilers > Industrial > Residual Oil > Grade 5 Oil
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.600E0 Lb per 1000 Gallons Residual Oil Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200405
  External Combustion Boilers > Industrial > Residual Oil > Cogeneration
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per 1000 Gallons Residual Oil Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200405
  External Combustion Boilers > Industrial > Residual Oil > Cogeneration
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per 1000 Gallons Residual Oil Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200501
  External Combustion Boilers > Industrial > Distillate Oil > Grades 1 and 2 Oil
  POLLUTANT Manganese NEI 7439965 CAS 7439-96-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E-6 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability

SCC 10200502
  External Combustion Boilers > Industrial > Distillate Oil > 10-100 Million Btu/hr **
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.550E0 Lb per 1000 Gallons Distillate Oil Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200503
  External Combustion Boilers > Industrial > Distillate Oil > < 10 Million Btu/hr **
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.000E-1 Lb per 1000 Gallons Distillate Oil Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200503
  External Combustion Boilers > Industrial > Distillate Oil > < 10 Million Btu/hr **
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : IMPINGEMENT PLATE SCRUBBER ,
  Emission Factor -- 2.900E0 Lb per 1000 Gallons Distillate Oil Burned;
Quality -- C    Emissions Factors Applicability

SCC 10200504
  External Combustion Boilers > Industrial > Distillate Oil > Grade 4 Oil
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.500E0 Lb per 1000 Gallons Residual Oil Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200504
  External Combustion Boilers > Industrial > Distillate Oil > Grade 4 Oil
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : WATER SPRAYS ,
  Emission Factor -- 2.800E-1 Lb per 1000 Gallons Residual Oil Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200504
  External Combustion Boilers > Industrial > Distillate Oil > Grade 4 Oil
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : WATER SPRAYS ,
  Emission Factor -- 1.780E0 Lb per 1000 Gallons Residual Oil Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200601
  External Combustion Boilers > Industrial > Natural Gas > > 100 Million Btu/hr
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : VENTURI SCRUBBER ,
  Emission Factor -- 9.100E0 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- C    Emissions Factors Applicability

SCC 10200601
  External Combustion Boilers > Industrial > Natural Gas > > 100 Million Btu/hr
  POLLUTANT Formaldehyde NEI 50000 CAS 50-00-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.500E-2 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200601
  External Combustion Boilers > Industrial > Natural Gas > > 100 Million Btu/hr
  POLLUTANT 2-Methyl Naphthalene NEI 91576 CAS 91-57-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.400E-5 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200601
  External Combustion Boilers > Industrial > Natural Gas > > 100 Million Btu/hr
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.900E0 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200601
  External Combustion Boilers > Industrial > Natural Gas > > 100 Million Btu/hr
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.600E0 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200602
  External Combustion Boilers > Industrial > Natural Gas > 10-100 Million Btu/hr
  POLLUTANT Acenaphthylene NEI 208968 CAS 208-96-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- <1.800E-6 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200602
  External Combustion Boilers > Industrial > Natural Gas > 10-100 Million Btu/hr
  POLLUTANT Benzene NEI 71432 CAS 71-43-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.100E-3 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200602
  External Combustion Boilers > Industrial > Natural Gas > 10-100 Million Btu/hr
  POLLUTANT Cadmium NEI 7440439 CAS 7440-43-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.100E-3 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200602
  External Combustion Boilers > Industrial > Natural Gas > 10-100 Million Btu/hr
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : WET SCRUBBER - LOW EFFICIENCY , ULTRA LOW NOX BURNERS (ULNB) ,
  Emission Factor -- 8.400E1 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200602
  External Combustion Boilers > Industrial > Natural Gas > 10-100 Million Btu/hr
  POLLUTANT Chrysene NEI 218019 CAS 218-01-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- <1.800E-6 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200602
  External Combustion Boilers > Industrial > Natural Gas > 10-100 Million Btu/hr
  POLLUTANT 2-Methyl Naphthalene NEI 91576 CAS 91-57-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.400E-5 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200602
  External Combustion Boilers > Industrial > Natural Gas > 10-100 Million Btu/hr
  POLLUTANT Nitrous oxide NEI CAS 10024-97-2
    Primary Control / Secondary Control : WET SCRUBBER - LOW EFFICIENCY ,
  Emission Factor -- 6.400E-1 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200602
  External Combustion Boilers > Industrial > Natural Gas > 10-100 Million Btu/hr
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.500E0 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- C    Emissions Factors Applicability

SCC 10200604
  External Combustion Boilers > Industrial > Natural Gas > Cogeneration
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.500E0 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- C    Emissions Factors Applicability

SCC 10200701
  External Combustion Boilers > Industrial > Process Gas > Petroleum Refinery Gas
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.500E1 Lb per Million Cubic Feet Process Gas Burned;
Quality -- U    Emissions Factors Applicability

SCC 10200701
  External Combustion Boilers > Industrial > Process Gas > Petroleum Refinery Gas
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.400E2 Lb per Million Cubic Feet Process Gas Burned;
Quality -- U    Emissions Factors Applicability

SCC 10200701
  External Combustion Boilers > Industrial > Process Gas > Petroleum Refinery Gas
  POLLUTANT Sulfur oxides (SOx) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Million Cubic Feet Process Gas Burned;
Quality -- U    Emissions Factors Applicability

SCC 10200704
  External Combustion Boilers > Industrial > Process Gas > Blast Furnace Gas
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.300E1 Lb per Million Cubic Feet Process Gas Burned;
Quality -- U    Emissions Factors Applicability

SCC 10200704
  External Combustion Boilers > Industrial > Process Gas > Blast Furnace Gas
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.600E0 Lb per Million Cubic Feet Process Gas Burned;
Quality -- U    Emissions Factors Applicability

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Arsenic NEI 7440382 CAS 7440-38-2
    Primary Control / Secondary Control : CATALYTIC AFTERBURNER ,
  Emission Factor -- 7.600E-6 Lb per MMBtu Heat Input;
Quality -- U    Emissions Factors Applicability

SCC 10200906
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Neodymium NEI CAS 7440-00-8
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.600E-5 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability

SCC 10201402
  External Combustion Boilers > Industrial > CO Boiler > Process Gas
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.400E2 Lb per Million Cubic Feet Process Gas Burned;
Quality -- U    Emissions Factors Applicability

SCC 10200804
  External Combustion Boilers > Industrial > Petroleum Coke > Cogeneration
  POLLUTANT Mercury NEI 7439976 CAS 7439-97-6
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- 5.220E-6 Lb per MMBtu Heat Input;
Quality -- U    Emissions Factors Applicability

SCC 10200804
  External Combustion Boilers > Industrial > Petroleum Coke > Cogeneration
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Coke Burned;
Quality -- U    Emissions Factors Applicability

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Acenaphthylene NEI 208968 CAS 208-96-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E-6 Lb per MMBtu Heat Input;
Quality -- A    Emissions Factors Applicability

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Carbazole NEI CAS 86-74-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.800E-6 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Carbon tetrachloride NEI 56235 CAS 56-23-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.500E-5 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Chlorobenzene NEI 108907 CAS 108-90-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.300E-5 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Hexavalent Chromium NEI 18540299 CAS 18540-29-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.500E-6 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Dioctyl phthalate NEI 117817 CAS 117-81-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.700E-8 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Ethylene dichloride NEI 107062 CAS 107-06-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.900E-5 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Hexachlorobiphenyls, total NEI CAS 26601-64-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.500E-10 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Hexachlorodibenzo-p-dioxins, total NEI 34465468 CAS 34465-46-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.600E-6 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Methyl ethyl ketone NEI 78933 CAS 78-93-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.400E-6 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Phenol NEI 108952 CAS 108-95-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.100E-5 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : EXTERNAL FLOATING ROOF TANK ,
  Emission Factor -- 1.700E-2 Lb per MMBtu Heat Input;
Quality -- A    Emissions Factors Applicability

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : EXTERNAL FLOATING ROOF TANK ,
  Emission Factor -- 6.500E-2 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Strontium NEI CAS 7440-24-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.000E-5 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT 2,4,4'-Trichlorobiphenyl NEI CAS 7012-37-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.600E-9 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10200902
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : IMPINGEMENT PLATE SCRUBBER ,
  Emission Factor -- 6.300E-1 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability

SCC 10200902
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Chromium NEI 7440473 CAS 7440-47-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.100E-5 Lb per MMBtu Heat Input;
Quality -- A    Emissions Factors Applicability

SCC 10200902
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Heptachlorodibenzofurans, total NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.400E-10 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10200902
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Indeno(1,2,3-cd)pyrene NEI 193395 CAS 193-39-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.700E-8 Lb per MMBtu Heat Input;
Quality -- B    Emissions Factors Applicability

SCC 10200902
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT 4-Nitrophenol NEI 100027 CAS 100-02-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.100E-7 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10200902
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT p-Tolualdehyde NEI CAS 104-87-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.100E-5 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Acenaphthylene NEI 208968 CAS 208-96-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E-6 Lb per MMBtu Heat Input;
Quality -- A    Emissions Factors Applicability

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Cadmium NEI 7440439 CAS 7440-43-9
    Primary Control / Secondary Control : CATALYTIC AFTERBURNER , ,
  Emission Factor -- 1.500E-6 Lb per MMBtu Heat Input;
Quality -- U    Emissions Factors Applicability

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Hexavalent Chromium NEI 18540299 CAS 18540-29-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.500E-6 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Fluoranthene NEI 206440 CAS 206-44-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.600E-7 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Fluoranthene NEI 206440 CAS 206-44-0
    Primary Control / Secondary Control : CATALYTIC AFTERBURNER ,
  Emission Factor -- 2.100E-6 Lb per MMBtu Heat Input;
Quality -- U    Emissions Factors Applicability

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Fluoranthene NEI 206440 CAS 206-44-0
    Primary Control / Secondary Control : CATALYTIC AFTERBURNER , INCREASED MONITORING FREQUENCY (IMF) OF PM CONTROLS ,
  Emission Factor -- 8.700E-8 Lb per MMBtu Heat Input;
Quality -- U    Emissions Factors Applicability

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Formaldehyde NEI 50000 CAS 50-00-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.400E-3 Lb per MMBtu Heat Input;
Quality -- A    Emissions Factors Applicability

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Mercury NEI 7439976 CAS 7439-97-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.500E-6 Lb per MMBtu Heat Input;
Quality -- A    Emissions Factors Applicability

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Nickel NEI 7440020 CAS 7440-02-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.300E-5 Lb per MMBtu Heat Input;
Quality -- A    Emissions Factors Applicability

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT 4-Nitrophenol NEI 100027 CAS 100-02-7
    Primary Control / Secondary Control : CATALYTIC AFTERBURNER , INCREASED MONITORING FREQUENCY (IMF) OF PM CONTROLS ,
  Emission Factor -- < 3.300E-7 Lb per MMBtu Heat Input;
Quality -- U    Emissions Factors Applicability

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Octachlorodibenzofurans, total NEI 39001020 CAS 39001-02-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.800E-11 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Phenol NEI 108952 CAS 108-95-2
    Primary Control / Secondary Control : CATALYTIC AFTERBURNER , INCREASED MONITORING FREQUENCY (IMF) OF PM CONTROLS ,
  Emission Factor -- 1.260E-5 Lb per MMBtu Heat Input;
Quality -- U    Emissions Factors Applicability

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Titanium NEI CAS 7440-32-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.000E-5 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10200904
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Benzo(k)fluoranthene NEI 207089 CAS 207-08-9
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 7.650E-7 Lb per Ton Bark Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200904
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : FABRIC FILTER - LOW TEMPERATURE , I.E. T<180F ,
  Emission Factor -- 1.400E1 Lb per Ton Wood Waste Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200904
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Polychlorinated dibenzo-p-dioxins, total NEI 136677093 CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.200E-8 Lb per Ton Bark Burned;
Quality -- C    Emissions Factors Applicability

SCC 10200905
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Benzo(k)fluoranthene NEI 207089 CAS 207-08-9
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 7.650E-7 Lb per Ton Wood/Bark Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200905
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Benzofluoranthenes NEI 56832736 CAS 56832-73-6
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.080E-6 Lb per Ton Wood/Bark Burned;
Quality -- E    Emissions Factors Applicability

SCC 10200905
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Lithium NEI CAS 7439-93-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 7.000E-5 Lb per Ton Wood/Bark Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200905
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Naphthalene NEI 91203 CAS 91-20-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.390E-3 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability

SCC 10200905
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Nickel NEI 7440020 CAS 7440-02-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 6.900E-5 Lb per Ton Wood/Bark Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200906
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Benzaldehyde NEI CAS 100-52-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.200E-5 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200906
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Hexavalent Chromium NEI 18540299 CAS 18540-29-9
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.600E-5 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200906
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Iodine NEI CAS 7553-56-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.800E-5 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200906
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Yttrium NEI CAS 7440-65-5
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 5.600E-5 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200906
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Zirconium NEI CAS 7440-67-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.500E-4 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200907
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood Cogeneration
  POLLUTANT Iodine NEI CAS 7553-56-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.800E-5 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability

SCC 10200907
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood Cogeneration
  POLLUTANT Nickel NEI 7440020 CAS 7440-02-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 6.900E-5 Lb per Ton Wood Burned;
Quality -- B    Emissions Factors Applicability

SCC 10200907
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood Cogeneration
  POLLUTANT Polychlorinated dibenzofurans, total NEI 136677106 CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.900E-8 Lb per Ton Wood Burned;
Quality -- C    Emissions Factors Applicability    Duplicate factor exists.

SCC 10200908
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Benzo(g,h,i)perylene NEI 191242 CAS 191-24-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 9.300E-8 Lb per MMBtu Heat Input;
Quality -- B    Emissions Factors Applicability

SCC 10200908
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Dichlorobiphenyl NEI CAS 25512-42-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.400E-10 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10200908
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Heptachlorodibenzofurans, total NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.400E-10 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10200908
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Isobutyraldehyde NEI CAS 78-84-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.200E-5 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10200908
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Manganese NEI 7439965 CAS 7439-96-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.600E-3 Lb per MMBtu Heat Input;
Quality -- A    Emissions Factors Applicability

SCC 10200908
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Potassium NEI CAS 7440-09-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.900E-2 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10200908
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT 2,4,6-Trichlorophenol NEI 88062 CAS 88-06-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- < 2.200E-8 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10200910
  External Combustion Boilers > Industrial > Wood/Bark Waste > Fuel cell/Dutch oven boilers **
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.600E0 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability

SCC 10301202
  External Combustion Boilers > Commercial/Institutional > Solid Waste > Refuse Derived Fuel
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E0 Lb per Ton Refuse Derived Fuel Burned;
Quality -- U    Emissions Factors Applicability

SCC 10300217
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Atmospheric Fluidized Bed Combustion: Bubbling Bed (Bituminous Coal)
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.290E1 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300602
  External Combustion Boilers > Commercial/Institutional > Natural Gas > 10-100 Million Btu/hr
  POLLUTANT Indeno(1,2,3-cd)pyrene NEI 193395 CAS 193-39-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- <1.800E-6 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT 2,4,4'-Trichlorobiphenyl NEI CAS 7012-37-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.600E-9 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 20100102
  Internal Combustion Engines > Electric Generation > Distillate Oil (Diesel) > Reciprocating
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.300E2 Lb per 1000 Gallons Distillate Oil (Diesel) Burned;
Quality -- D    Emissions Factors Applicability

SCC 20100102
  Internal Combustion Engines > Electric Generation > Distillate Oil (Diesel) > Reciprocating
  POLLUTANT Ethylbenzene NEI 100414 CAS 100-41-4
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.070E-3 Lb per 1000 Gallons Distillate Oil (Diesel) Burned;
Quality -- U    Emissions Factors Applicability

SCC 10201002
  External Combustion Boilers > Industrial > Liquified Petroleum Gas (LPG) > Propane
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.060E-1 Lb per 1000 Gallons Propane Burned;
Quality -- E    Emissions Factors Applicability

SCC 10201101
  External Combustion Boilers > Industrial > Bagasse > All Boiler Sizes
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CENTRIFUGAL COLLECTOR (CYCLONE) - MEDIUM EFFICIENCY ,
  Emission Factor -- 8.400E0 Lb per Ton Bagasse Burned;
Quality -- D    Emissions Factors Applicability

SCC 10201201
  External Combustion Boilers > Industrial > Solid Waste > Specify Waste Material in Comments
  POLLUTANT Benzene NEI 71432 CAS 71-43-2
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- 5.290E-3 Lb per MMBtu Heat Input;
Quality -- U    Emissions Factors Applicability

SCC 10201302
  External Combustion Boilers > Industrial > Liquid Waste > Waste Oil
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E0 Lb per 1000 Gallons Waste Oil Burned;
Quality -- U    Emissions Factors Applicability

SCC 10300101
  External Combustion Boilers > Commercial/Institutional > Anthracite Coal > Pulverized Coal
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : WATER SPRAYS ,
  Emission Factor -- Formula Lb per Ton Anthracite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300102
  External Combustion Boilers > Commercial/Institutional > Anthracite Coal > Traveling Grate (Overfeed) Stoker
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Anthracite Burned;
Quality -- U    Emissions Factors Applicability

SCC 10300103
  External Combustion Boilers > Commercial/Institutional > Anthracite Coal > Hand-fired
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.650E-1 Lb per 1000 Tons Anthracite Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300103
  External Combustion Boilers > Commercial/Institutional > Anthracite Coal > Hand-fired
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 9.000E1 Lb per Ton Anthracite Burned;
Quality -- B    Emissions Factors Applicability

SCC 10300203
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Cyclone Furnace (Bituminous Coal)
  POLLUTANT Benzo(a)anthracene NEI 56553 CAS 56-55-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 8.000E-8 Lb per Ton Bituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10300203
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Cyclone Furnace (Bituminous Coal)
  POLLUTANT Dioctyl phthalate NEI 117817 CAS 117-81-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 7.300E-5 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300203
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Cyclone Furnace (Bituminous Coal)
  POLLUTANT Fluorene NEI 86737 CAS 86-73-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 9.100E-7 Lb per Ton Bituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10300203
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Cyclone Furnace (Bituminous Coal)
  POLLUTANT Methyl chloride NEI 74873 CAS 74-87-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 5.300E-4 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300203
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Cyclone Furnace (Bituminous Coal)
  POLLUTANT 5-Methyl Chrysene NEI 3697243 CAS 3697-24-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.200E-8 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300203
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Cyclone Furnace (Bituminous Coal)
  POLLUTANT N-Hexane NEI 110543 CAS 110-54-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 6.700E-5 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300203
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Cyclone Furnace (Bituminous Coal)
  POLLUTANT Octachlorodibenzo-p-dioxins, total NEI 3268879 CAS 3268-87-9
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.160E-10 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300203
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Cyclone Furnace (Bituminous Coal)
  POLLUTANT Octachlorodibenzofurans, total NEI 39001020 CAS 39001-02-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 6.630E-11 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300203
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Cyclone Furnace (Bituminous Coal)
  POLLUTANT Toluene NEI 108883 CAS 108-88-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.400E-4 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300205
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Wet Bottom (Bituminous Coal)
  POLLUTANT Beryllium NEI 7440417 CAS 7440-41-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.100E-5 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability

SCC 10300205
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Wet Bottom (Bituminous Coal)
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E-1 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300206
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Acetophenone NEI 98862 CAS 98-86-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.500E-5 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300206
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Carbon sulfide NEI 75150 CAS 75-15-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.300E-4 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300206
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Heptachlorodibenzofurans, total NEI CAS
    Primary Control / Secondary Control : DUST SUPPRESSION BY WATER SPRAYS , DUCT SORBENT INJECTION ,
  Emission Factor -- 4.390E-8 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300206
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Magnesium NEI CAS 7439-95-4
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.100E-2 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300206
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Methane NEI CAS 74-82-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.000E-2 Lb per Ton Bituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10300206
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT N-Hexane NEI 110543 CAS 110-54-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 6.700E-5 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300206
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Pentachlorodibenzo-p-dioxins, total NEI CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.470E-11 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300206
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Pyrene NEI 129000 CAS 129-00-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.300E-7 Lb per Ton Bituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10300206
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Tetrachlorodibenzofurans, total NEI CAS
    Primary Control / Secondary Control : DUST SUPPRESSION BY WATER SPRAYS , DUCT SORBENT INJECTION ,
  Emission Factor -- 2.490E-9 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300207
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Overfeed Stoker (Bituminous Coal)
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E0 Lb per Ton Bituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10300207
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Overfeed Stoker (Bituminous Coal)
  POLLUTANT Nitrous oxide NEI CAS 10024-97-2
    Primary Control / Secondary Control : WATER SPRAYS ,
  Emission Factor -- 4.000E-2 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300208
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Underfeed Stoker (Bituminous Coal)
  POLLUTANT Lead NEI 7439921 CAS 7439-92-1
    Primary Control / Secondary Control : CATALYTIC AFTERBURNER ,
  Emission Factor -- 3.930E-2 Lb per Ton Bituminous Coal Burned;
Quality -- U    Emissions Factors Applicability    Duplicate factor exists.

SCC 10300208
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Underfeed Stoker (Bituminous Coal)
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 9.500E0 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300209
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Spreader Stoker (Bituminous Coal)
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E0 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300209
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Spreader Stoker (Bituminous Coal)
  POLLUTANT Formaldehyde NEI 50000 CAS 50-00-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.210E-4 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability

SCC 10300209
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Spreader Stoker (Bituminous Coal)
  POLLUTANT Nitrous oxide NEI CAS 10024-97-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.000E-2 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300209
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Spreader Stoker (Bituminous Coal)
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : SULFURIC ACID PLANT ,
  Emission Factor -- 3.000E-1 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300216
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential) (Bituminous Coal)
  POLLUTANT Antimony NEI 7440360 CAS 7440-36-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.800E-5 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300216
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential) (Bituminous Coal)
  POLLUTANT Beryllium NEI 7440417 CAS 7440-41-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.100E-5 Lb per Ton Bituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300216
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential) (Bituminous Coal)
  POLLUTANT Ethylbenzene NEI 100414 CAS 100-41-4
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 9.400E-5 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300216
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential) (Bituminous Coal)
  POLLUTANT Fluoranthene NEI 206440 CAS 206-44-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 7.100E-7 Lb per Ton Bituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10300216
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential) (Bituminous Coal)
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 30101801
  Industrial Processes > Chemical Manufacturing > Plastics Production > Polyvinyl Chlorides and Copolymers ** (Use 6-46-3X0-XX)
  POLLUTANT Chloroprene NEI 126998 CAS 126-99-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- < 8.000E-5 Lb per Ton Product Produced;
Quality -- U    Emissions Factors Applicability

SCC 30101801
  Industrial Processes > Chemical Manufacturing > Plastics Production > Polyvinyl Chlorides and Copolymers ** (Use 6-46-3X0-XX)
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : DUCT SORBENT INJECTION ,
  Emission Factor -- 3.500E1 Lb per Ton Product Produced;
Quality -- E    Emissions Factors Applicability

SCC 30104010
  Industrial Processes > Chemical Manufacturing > Urea Production > Fluidized Bed Prilling (Agricultural Grade)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.700E0 Lb per Ton Urea Produced;
Quality -- U    Emissions Factors Applicability

SCC 10300216
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential) (Bituminous Coal)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300216
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential) (Bituminous Coal)
  POLLUTANT Styrene NEI 100425 CAS 100-42-5
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.500E-5 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300218
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Atmospheric Fluidized Bed Combustion: Circulating Bed (Bitum. Coal)
  POLLUTANT Ethyl chloride NEI 75003 CAS 75-00-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.200E-5 Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300218
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Atmospheric Fluidized Bed Combustion: Circulating Bed (Bitum. Coal)
  POLLUTANT Methane NEI CAS 74-82-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E-2 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300222
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Cyanide NEI 57125 CAS 57-12-5
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.500E-3 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300222
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Ethyl chloride NEI 75003 CAS 75-00-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.200E-5 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300222
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Hexachlorodibenzofurans, total NEI CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.920E-10 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300222
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Isophorone NEI 78591 CAS 78-59-1
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 5.800E-4 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300222
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Methyl chloride NEI 74873 CAS 74-87-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 5.300E-4 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300222
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Nickel NEI 7440020 CAS 7440-02-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.800E-4 Lb per Ton Subbituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300222
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Pentachlorodibenzo-p-dioxins, total NEI CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.470E-11 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300222
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Polychlorinated dibenzo-p-dioxins and furans, total NEI 136677093 CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.760E-9 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300222
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Polychlorinated dibenzo-p-dioxins and furans, total NEI 136677093 CAS
    Primary Control / Secondary Control : DUST SUPPRESSION BY WATER SPRAYS , DUCT SORBENT INJECTION ,
  Emission Factor -- 2.440E-7 Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300222
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Polychlorinated dibenzofurans, total NEI 136677106 CAS
    Primary Control / Secondary Control : DUST SUPPRESSION BY WATER SPRAYS , DUCT SORBENT INJECTION ,
  Emission Factor -- 2.010E-7 Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300222
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Tetrachlorodibenzo-p-dioxins, total NEI CAS
    Primary Control / Secondary Control : DUST SUPPRESSION BY WATER SPRAYS , DUCT SORBENT INJECTION ,
  Emission Factor -- 3.930E-10 Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300223
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Cyclone Furnace (Subbituminous Coal)
  POLLUTANT Arsenic NEI 7440382 CAS 7440-38-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.100E-4 Lb per Ton Subbituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300223
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Cyclone Furnace (Subbituminous Coal)
  POLLUTANT Benzo(a)anthracene NEI 56553 CAS 56-55-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 8.000E-8 Lb per Ton Subbituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10300223
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Cyclone Furnace (Subbituminous Coal)
  POLLUTANT Nitrous oxide NEI CAS 10024-97-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 9.000E-2 Lb per Ton Subbituminous Coal Burned;
Quality -- B    Emissions Factors Applicability

SCC 10300223
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Cyclone Furnace (Subbituminous Coal)
  POLLUTANT Polychlorinated dibenzo-p-dioxins and furans, total NEI 136677093 CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.760E-9 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300223
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Cyclone Furnace (Subbituminous Coal)
  POLLUTANT 2,3,7,8-Tetrachlorodibenzo-p-dioxin NEI 1746016 CAS 1746-01-6
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.430E-11 Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300224
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Spreader Stoker (Subbituminous Coal)
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.000E-2 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10300225
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Traveling Grate (Overfeed) Stoker (Subbituminous Coal)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E0 Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300226
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom Tangential (Subbituminous Coal)
  POLLUTANT Carbon sulfide NEI 75150 CAS 75-15-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.300E-4 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300226
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom Tangential (Subbituminous Coal)
  POLLUTANT Chlorobenzene NEI 108907 CAS 108-90-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.200E-5 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300226
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom Tangential (Subbituminous Coal)
  POLLUTANT Formaldehyde NEI 50000 CAS 50-00-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.400E-4 Lb per Ton Subbituminous Coal Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300226
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom Tangential (Subbituminous Coal)
  POLLUTANT Propionaldehyde NEI 123386 CAS 123-38-6
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.800E-4 Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300305
  External Combustion Boilers > Commercial/Institutional > Lignite > Pulverized Coal: Dry Bottom, Wall Fired
  POLLUTANT Ethylene dibromide NEI 106934 CAS 106-93-4
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.200E-6 Lb per Ton Lignite Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300305
  External Combustion Boilers > Commercial/Institutional > Lignite > Pulverized Coal: Dry Bottom, Wall Fired
  POLLUTANT Naphthalene NEI 91203 CAS 91-20-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.300E-5 Lb per Ton Lignite Burned;
Quality -- C    Emissions Factors Applicability

SCC 10300305
  External Combustion Boilers > Commercial/Institutional > Lignite > Pulverized Coal: Dry Bottom, Wall Fired
  POLLUTANT Phenol NEI 108952 CAS 108-95-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.600E-5 Lb per Ton Lignite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300305
  External Combustion Boilers > Commercial/Institutional > Lignite > Pulverized Coal: Dry Bottom, Wall Fired
  POLLUTANT Pyrene NEI 129000 CAS 129-00-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.300E-7 Lb per Ton Lignite Burned;
Quality -- B    Emissions Factors Applicability

SCC 10300306
  External Combustion Boilers > Commercial/Institutional > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Benzo(g,h,i)perylene NEI 191242 CAS 191-24-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.700E-8 Lb per Ton Lignite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300306
  External Combustion Boilers > Commercial/Institutional > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Benzofluoranthenes NEI 56832736 CAS 56832-73-6
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.100E-7 Lb per Ton Lignite Burned;
Quality -- B    Emissions Factors Applicability

SCC 10300306
  External Combustion Boilers > Commercial/Institutional > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Benzyl chloride NEI 100447 CAS 100-44-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 7.000E-4 Lb per Ton Lignite Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300306
  External Combustion Boilers > Commercial/Institutional > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Bromoform NEI 75252 CAS 75-25-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.900E-5 Lb per Ton Lignite Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300306
  External Combustion Boilers > Commercial/Institutional > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Chromium NEI 7440473 CAS 7440-47-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.600E-4 Lb per Ton Lignite Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300306
  External Combustion Boilers > Commercial/Institutional > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Ethylene dibromide NEI 106934 CAS 106-93-4
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.200E-6 Lb per Ton Lignite Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300306
  External Combustion Boilers > Commercial/Institutional > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Fluorene NEI 86737 CAS 86-73-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 9.100E-7 Lb per Ton Lignite Burned;
Quality -- B    Emissions Factors Applicability

SCC 10300307
  External Combustion Boilers > Commercial/Institutional > Lignite > Traveling Grate (Overfeed) Stoker
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E0 Lb per Ton Lignite Burned;
Quality -- B    Emissions Factors Applicability

SCC 10300307
  External Combustion Boilers > Commercial/Institutional > Lignite > Traveling Grate (Overfeed) Stoker
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Lignite Burned;
Quality -- U    Emissions Factors Applicability

SCC 10300309
  External Combustion Boilers > Commercial/Institutional > Lignite > Spreader Stoker
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Lignite Coal Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300403
  External Combustion Boilers > Commercial/Institutional > Residual Oil > < 10 Million Btu/hr **
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.500E1 Lb per 1000 Gallons Residual Oil Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300403
  External Combustion Boilers > Commercial/Institutional > Residual Oil > < 10 Million Btu/hr **
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per 1000 Gallons Residual Oil Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300403
  External Combustion Boilers > Commercial/Institutional > Residual Oil > < 10 Million Btu/hr **
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per 1000 Gallons Residual Oil Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300404
  External Combustion Boilers > Commercial/Institutional > Residual Oil > Grade 5 Oil
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.500E1 Lb per 1000 Gallons Residual Oil (No. 5) Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300404
  External Combustion Boilers > Commercial/Institutional > Residual Oil > Grade 5 Oil
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.500E0 Lb per 1000 Gallons Residual Oil Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300404
  External Combustion Boilers > Commercial/Institutional > Residual Oil > Grade 5 Oil
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.300E0 Lb per 1000 Gallons Residual Oil Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300501
  External Combustion Boilers > Commercial/Institutional > Distillate Oil > Grades 1 and 2 Oil
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : WET SCRUBBER - LOW EFFICIENCY , ULTRA LOW NOX BURNERS (ULNB) ,
  Emission Factor -- 1.080E0 Lb per 1000 Gallons Distillate Oil Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300501
  External Combustion Boilers > Commercial/Institutional > Distillate Oil > Grades 1 and 2 Oil
  POLLUTANT Sulfur dioxide NEI SO2 CAS 7446-09-5
    Primary Control / Secondary Control : WET SCRUBBER - LOW EFFICIENCY , ULTRA LOW NOX BURNERS (ULNB) ,
  Emission Factor -- Formula Lb per 1000 Gallons Distillate Oil (No. 1 & 2) Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300502
  External Combustion Boilers > Commercial/Institutional > Distillate Oil > 10-100 Million Btu/hr **
  POLLUTANT Sulfur trioxide NEI CAS 7446-11-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per 1000 Gallons Distillate Oil Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300503
  External Combustion Boilers > Commercial/Institutional > Distillate Oil > < 10 Million Btu/hr **
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.000E0 Lb per 1000 Gallons Distillate Oil Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300503
  External Combustion Boilers > Commercial/Institutional > Distillate Oil > < 10 Million Btu/hr **
  POLLUTANT Sulfur dioxide NEI SO2 CAS 7446-09-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per 1000 Gallons Distillate Oil Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300503
  External Combustion Boilers > Commercial/Institutional > Distillate Oil > < 10 Million Btu/hr **
  POLLUTANT Total non-methane organic compounds (TNMOC) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.400E-1 Lb per 1000 Gallons Distillate Oil Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300504
  External Combustion Boilers > Commercial/Institutional > Distillate Oil > Grade 4 Oil
  POLLUTANT Sulfur trioxide NEI CAS 7446-11-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per 1000 Gallons Distillate Oil (No. 4) Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300601
  External Combustion Boilers > Commercial/Institutional > Natural Gas > > 100 Million Btu/hr
  POLLUTANT Chromium NEI 7440473 CAS 7440-47-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.400E-3 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- D    Emissions Factors Applicability

SCC 10300601
  External Combustion Boilers > Commercial/Institutional > Natural Gas > > 100 Million Btu/hr
  POLLUTANT Dichlorobenzene, mixed isomers NEI CAS 25321-22-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.200E-3 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300601
  External Combustion Boilers > Commercial/Institutional > Natural Gas > > 100 Million Btu/hr
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.800E2 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- A    Emissions Factors Applicability    Duplicate factor exists.

SCC 10300601
  External Combustion Boilers > Commercial/Institutional > Natural Gas > > 100 Million Btu/hr
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : WET SCRUBBER - LOW EFFICIENCY ,
  Emission Factor -- 1.400E2 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- A    Emissions Factors Applicability

SCC 10300602
  External Combustion Boilers > Commercial/Institutional > Natural Gas > 10-100 Million Btu/hr
  POLLUTANT Dibenzo(a,h) anthracene NEI 53703 CAS 53-70-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- <1.200E-6 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300602
  External Combustion Boilers > Commercial/Institutional > Natural Gas > 10-100 Million Btu/hr
  POLLUTANT N-Pentane NEI CAS 109-66-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.600E0 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300603
  External Combustion Boilers > Commercial/Institutional > Natural Gas > < 10 Million Btu/hr
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : WET SCRUBBER - LOW EFFICIENCY , ULTRA LOW NOX BURNERS (ULNB) ,
  Emission Factor -- 8.400E1 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- B    Emissions Factors Applicability

SCC 10300603
  External Combustion Boilers > Commercial/Institutional > Natural Gas > < 10 Million Btu/hr
  POLLUTANT Chrysene NEI 218019 CAS 218-01-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- <1.800E-6 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300603
  External Combustion Boilers > Commercial/Institutional > Natural Gas > < 10 Million Btu/hr
  POLLUTANT Nickel NEI 7440020 CAS 7440-02-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.100E-3 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- C    Emissions Factors Applicability

SCC 10300603
  External Combustion Boilers > Commercial/Institutional > Natural Gas > < 10 Million Btu/hr
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.900E0 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- B    Emissions Factors Applicability

SCC 10300603
  External Combustion Boilers > Commercial/Institutional > Natural Gas > < 10 Million Btu/hr
  POLLUTANT Selenium NEI 7782492 CAS 7782-49-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- <2.400E-5 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- E    Emissions Factors Applicability

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Benzo(a)pyrene NEI 50328 CAS 50-32-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.600E-6 Lb per MMBtu Heat Input;
Quality -- A    Emissions Factors Applicability

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Beryllium NEI 7440417 CAS 7440-41-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.100E-6 Lb per MMBtu Heat Input;
Quality -- B    Emissions Factors Applicability

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Chloroform NEI 67663 CAS 67-66-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.800E-5 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Methyl bromide NEI 74839 CAS 74-83-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.500E-5 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT 4-Nitrophenol NEI 100027 CAS 100-02-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.100E-7 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Octachlorodibenzo-p-dioxins, total NEI 3268879 CAS 3268-87-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.600E-8 Lb per MMBtu Heat Input;
Quality -- B    Emissions Factors Applicability

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Perchloroethylene NEI 127184 CAS 127-18-4
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.800E-5 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Phenol NEI 108952 CAS 108-95-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.100E-5 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : CENTRIFUGAL COLLECTOR (CYCLONE) - MEDIUM EFFICIENCY ,
  Emission Factor -- 2.900E-1 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Total organic compounds (TOC) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.900E-2 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Acenaphthylene NEI 208968 CAS 208-96-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E-6 Lb per MMBtu Heat Input;
Quality -- A    Emissions Factors Applicability

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : IMPINGEMENT PLATE SCRUBBER ,
  Emission Factor -- 6.300E-1 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : VENTURI SCRUBBER ,
  Emission Factor -- 3.100E-1 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Antimony NEI 7440360 CAS 7440-36-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.900E-6 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Barium NEI CAS 7440-39-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.700E-4 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Benzo(b)fluoranthene NEI 205992 CAS 205-99-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.000E-7 Lb per MMBtu Heat Input;
Quality -- B    Emissions Factors Applicability

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Hexavalent Chromium NEI 18540299 CAS 18540-29-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.500E-6 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Dichloromethane NEI 75092 CAS 75-09-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.900E-4 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Hydrogen chloride NEI 7647010 CAS 7647-01-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.900E-2 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Pentachlorophenol(PCP) NEI 87865 CAS 87-86-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.100E-8 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10300903
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Benzo(a)pyrene NEI 50328 CAS 50-32-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.600E-6 Lb per MMBtu Heat Input;
Quality -- A    Emissions Factors Applicability

SCC 10300903
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Dichlorobiphenyl NEI CAS 25512-42-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.400E-10 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10300903
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Fluoranthene NEI 206440 CAS 206-44-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.600E-7 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10300903
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : DUCT SORBENT INJECTION ,
  Emission Factor -- 1.000E-1 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10300903
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Propylene dichloride NEI 78875 CAS 78-87-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.300E-5 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10300903
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT 2,3,7,8-Tetrachlorodibenzofuran NEI 51207319 CAS 51207-31-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 9.000E-11 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10300903
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Titanium NEI CAS 7440-32-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.000E-5 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10300903
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT o-Tolualdehyde NEI CAS 529-20-4
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.200E-6 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10300903
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Trichlorofluoromethane NEI CAS 75-69-4
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.100E-5 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10300908
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E-1 Lb per MMBtu Heat Input;
Quality -- A    Emissions Factors Applicability

SCC 10300908
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Chromium NEI 7440473 CAS 7440-47-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.100E-5 Lb per MMBtu Heat Input;
Quality -- A    Emissions Factors Applicability

SCC 10300908
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Chrysene NEI 218019 CAS 218-01-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.800E-8 Lb per MMBtu Heat Input;
Quality -- B    Emissions Factors Applicability

SCC 10300908
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Cobalt NEI 7440484 CAS 7440-48-4
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.500E-6 Lb per MMBtu Heat Input;
Quality -- C    Emissions Factors Applicability

SCC 10300908
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Ethylene dichloride NEI 107062 CAS 107-06-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.900E-5 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10300908
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Indeno(1,2,3-cd)pyrene NEI 193395 CAS 193-39-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.700E-8 Lb per MMBtu Heat Input;
Quality -- B    Emissions Factors Applicability

SCC 10300908
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Pentachlorodibenzo-p-dioxins, total NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.500E-9 Lb per MMBtu Heat Input;
Quality -- B    Emissions Factors Applicability

SCC 10300908
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Potassium NEI CAS 7440-09-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.900E-2 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10300908
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Dry Wood (<20% moisture)
  POLLUTANT Yttrium NEI CAS 7440-65-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.000E-7 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability

SCC 10300910
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Fuel cell/Dutch oven boilers **
  POLLUTANT Sulfur oxides (SOx) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.500E-2 Lb per Ton Wood/Bark Burned;
Quality -- B    Emissions Factors Applicability

SCC 10300911
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Stoker boilers **
  POLLUTANT Sulfur oxides (SOx) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.500E-2 Lb per Ton Wood/Bark Burned;
Quality -- B    Emissions Factors Applicability

SCC 10300911
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Stoker boilers **
  POLLUTANT Total organic compounds (TOC) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.200E-1 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability

SCC 10300912
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Fluidized bed combustion boilers
  POLLUTANT Carbon dioxide NEI CO2 CAS 124-38-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.800E3 Lb per Ton Wood/Bark Burned;
Quality -- B    Emissions Factors Applicability

SCC 10300912
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Fluidized bed combustion boilers
  POLLUTANT Sulfur oxides (SOx) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.500E-2 Lb per Ton Wood/Bark Burned;
Quality -- B    Emissions Factors Applicability

SCC 10301001
  External Combustion Boilers > Commercial/Institutional > Liquified Petroleum Gas (LPG) > Butane
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.044E0 Lb per 1000 Gallons Butane Burned;
Quality -- E    Emissions Factors Applicability

SCC 10301002
  External Combustion Boilers > Commercial/Institutional > Liquified Petroleum Gas (LPG) > Propane
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 9.060E-1 Lb per 1000 Gallons Propane Burned;
Quality -- E    Emissions Factors Applicability

SCC 10301302
  External Combustion Boilers > Commercial/Institutional > Liquid Waste > Waste Oil
  POLLUTANT Carbon dioxide NEI CO2 CAS 124-38-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.200E4 Lb per 1000 Gallons Waste Oil Burned;
Quality -- C    Emissions Factors Applicability

SCC 10301302
  External Combustion Boilers > Commercial/Institutional > Liquid Waste > Waste Oil
  POLLUTANT Hydrogen chloride NEI 7647010 CAS 7647-01-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per 1000 Gallons Waste Oil Burned;
Quality -- C    Emissions Factors Applicability

SCC 10500106
  External Combustion Boilers > Space Heaters > Industrial > Natural Gas
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.300E0 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- U    Emissions Factors Applicability

SCC 10500110
  External Combustion Boilers > Space Heaters > Industrial > Liquified Petroleum Gas (LPG)
  POLLUTANT Sulfur oxides (SOx) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per 1000 Gallons Liquified Petroleum Gas (LPG) Burned;
Quality -- U    Emissions Factors Applicability

SCC 10500114
  External Combustion Boilers > Space Heaters > Industrial > Waste Oil: Vaporizing Burner
  POLLUTANT Cobalt NEI 7440484 CAS 7440-48-4
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.700E-3 Lb per 1000 Gallons Waste Oil Burned;
Quality -- D    Emissions Factors Applicability

SCC 10500114
  External Combustion Boilers > Space Heaters > Industrial > Waste Oil: Vaporizing Burner
  POLLUTANT Dioctyl phthalate NEI 117817 CAS 117-81-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.200E-3 Lb per 1000 Gallons Waste Oil Burned;
Quality -- D    Emissions Factors Applicability

SCC 10500202
  External Combustion Boilers > Space Heaters > Commercial/Institutional > Coal **
  POLLUTANT Sulfur oxides (SOx) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Coal Burned;
Quality -- U    Emissions Factors Applicability

SCC 10500205
  External Combustion Boilers > Space Heaters > Commercial/Institutional > Distillate Oil
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.760E0 Lb per 1000 Gallons Distillate Oil Burned;
Quality -- U    Emissions Factors Applicability

SCC 10500206
  External Combustion Boilers > Space Heaters > Commercial/Institutional > Natural Gas
  POLLUTANT Sulfur oxides (SOx) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E-1 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- U    Emissions Factors Applicability

SCC 10500209
  External Combustion Boilers > Space Heaters > Commercial/Institutional > Wood
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.800E0 Lb per Ton Wood Burned;
Quality -- U    Emissions Factors Applicability

SCC 10500213
  External Combustion Boilers > Space Heaters > Commercial/Institutional > Waste Oil: Air Atomized Burner
  POLLUTANT Lead NEI 7439921 CAS 7439-92-1
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.000E0 Lb per 1000 Gallons Waste Oil Burned;
Quality -- D    Emissions Factors Applicability

SCC 10500213
  External Combustion Boilers > Space Heaters > Commercial/Institutional > Waste Oil: Air Atomized Burner
  POLLUTANT Nickel NEI 7440020 CAS 7440-02-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.600E-1 Lb per 1000 Gallons Waste Oil Burned;
Quality -- D    Emissions Factors Applicability

SCC 10500213
  External Combustion Boilers > Space Heaters > Commercial/Institutional > Waste Oil: Air Atomized Burner
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per 1000 Gallons Waste Oil Burned;
Quality -- E    Emissions Factors Applicability

SCC 10500214
  External Combustion Boilers > Space Heaters > Commercial/Institutional > Waste Oil: Vaporizing Burner
  POLLUTANT Benzo(a)pyrene NEI 50328 CAS 50-32-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.000E-3 Lb per 1000 Gallons Waste Oil Burned;
Quality -- D    Emissions Factors Applicability

SCC 10500214
  External Combustion Boilers > Space Heaters > Commercial/Institutional > Waste Oil: Vaporizing Burner
  POLLUTANT Manganese NEI 7439965 CAS 7439-96-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.200E-3 Lb per 1000 Gallons Waste Oil Burned;
Quality -- D    Emissions Factors Applicability

SCC 20100101
  Internal Combustion Engines > Electric Generation > Distillate Oil (Diesel) > Turbine
  POLLUTANT Beryllium NEI 7440417 CAS 7440-41-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- < 3.100E-7 Lb per MMBtu Fuel Input;
Quality -- D    Emissions Factors Applicability

SCC 20100101
  Internal Combustion Engines > Electric Generation > Distillate Oil (Diesel) > Turbine
  POLLUTANT Selenium NEI 7782492 CAS 7782-49-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- < 2.500E-5 Lb per MMBtu Fuel Input;
Quality -- D    Emissions Factors Applicability

SCC 20100201
  Internal Combustion Engines > Electric Generation > Natural Gas > Turbine
  POLLUTANT Formaldehyde NEI 50000 CAS 50-00-0
    Primary Control / Secondary Control : ELECTROSTATIC PRECIPITATOR - DRY (DESP) ,
  Emission Factor -- 2.000E-5 Lb per MMBtu Fuel Input;
Quality -- D    Emissions Factors Applicability

SCC 20100201
  Internal Combustion Engines > Electric Generation > Natural Gas > Turbine
  POLLUTANT Naphthalene NEI 91203 CAS 91-20-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.300E-6 Lb per MMBtu Fuel Input;
Quality -- C    Emissions Factors Applicability

SCC 20100201
  Internal Combustion Engines > Electric Generation > Natural Gas > Turbine
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.200E-1 Lb per MMBtu Fuel Input;
Quality -- A    Emissions Factors Applicability

SCC 20100201
  Internal Combustion Engines > Electric Generation > Natural Gas > Turbine
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : ALKALINE FLY ASH SCRUBBING ,
  Emission Factor -- 6.600E-3 Lb per MMBtu Fuel Input;
Quality -- C    Emissions Factors Applicability

SCC 20100206
  Internal Combustion Engines > Electric Generation > Natural Gas > Reciprocating: Evaporative Losses (Fuel Delivery System)
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : IMPINGEMENT PLATE SCRUBBER ,
  Emission Factor -- 1.800E1 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- C    Emissions Factors Applicability

SCC 20100207
  Internal Combustion Engines > Electric Generation > Natural Gas > Reciprocating: Exhaust
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : IMPINGEMENT PLATE SCRUBBER ,
  Emission Factor -- 1.800E1 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- C    Emissions Factors Applicability

SCC 20100901
  Internal Combustion Engines > Electric Generation > Kerosene/Naphtha (Jet Fuel) > Turbine
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.800E-1 Lb per MMBtu Fuel Input;
Quality -- C    Emissions Factors Applicability

SCC 20100905
  Internal Combustion Engines > Electric Generation > Kerosene/Naphtha (Jet Fuel) > Reciprocating: Crankcase Blowby
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : IMPINGEMENT PLATE SCRUBBER ,
  Emission Factor -- 2.900E0 Lb per 1000 Gallons Jet Fuel Burned;
Quality -- C    Emissions Factors Applicability

SCC 20200101
  Internal Combustion Engines > Industrial > Distillate Oil (Diesel) > Turbine
  POLLUTANT Arsenic NEI 7440382 CAS 7440-38-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- < 1.100E-5 Lb per MMBtu Fuel Input;
Quality -- D    Emissions Factors Applicability

SCC 20200101
  Internal Combustion Engines > Industrial > Distillate Oil (Diesel) > Turbine
  POLLUTANT Benzo(a)pyrene NEI 50328 CAS 50-32-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.000E-2 mg per Kiloliter Oil Burned;
Quality -- U    Emissions Factors Applicability

SCC 20200101
  Internal Combustion Engines > Industrial > Distillate Oil (Diesel) > Turbine
  POLLUTANT Carbon dioxide NEI CO2 CAS 124-38-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.570E2 Lb per MMBtu Fuel Input;
Quality -- A    Emissions Factors Applicability

SCC 20200101
  Internal Combustion Engines > Industrial > Distillate Oil (Diesel) > Turbine
  POLLUTANT Fluoranthene NEI 206440 CAS 206-44-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 9.400E-1 mg per Kiloliter Oil Burned;
Quality -- U    Emissions Factors Applicability

SCC 20200102
  Internal Combustion Engines > Industrial > Distillate Oil (Diesel) > Reciprocating
  POLLUTANT Benzo(a)pyrene NEI 50328 CAS 50-32-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- < 1.880E-7 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability

SCC 20200102
  Internal Combustion Engines > Industrial > Distillate Oil (Diesel) > Reciprocating
  POLLUTANT Dibenzo(a,h) anthracene NEI 53703 CAS 53-70-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- < 5.830E-7 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability

SCC 20200102
  Internal Combustion Engines > Industrial > Distillate Oil (Diesel) > Reciprocating
  POLLUTANT Indeno(1,2,3-cd)pyrene NEI 193395 CAS 193-39-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- < 3.750E-7 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability

SCC 20200202
  Internal Combustion Engines > Industrial > Natural Gas > Reciprocating
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.011E1 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- U    Emissions Factors Applicability

SCC 20200902
  Internal Combustion Engines > Industrial > Kerosene/Naphtha (Jet Fuel) > Reciprocating
  POLLUTANT Total organic compounds (TOC) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.500E-1 Lb per MMBtu Fuel Input;
Quality -- D    Emissions Factors Applicability

SCC 30102114
  Industrial Processes > Chemical Manufacturing > Sodium Carbonate > Rotary Dryer: Steam Tube
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.400E1 Lb per Ton Sodium Carbonate Produced;
Quality -- U    Emissions Factors Applicability

SCC 30102123
  Industrial Processes > Chemical Manufacturing > Sodium Carbonate > Ore Mining
  POLLUTANT PM, primary NEI PM-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.300E0 Lb per Ton Sodium Carbonate Produced;
Quality -- D    Emissions Factors Applicability

SCC 30102124
  Industrial Processes > Chemical Manufacturing > Sodium Carbonate > Ore Transfer
  POLLUTANT PM, primary NEI PM-PRI CAS
    Primary Control / Secondary Control : CONSERVATION VENT , ROTOCLONE ,
  Emission Factor -- 2.000E-4 Lb per Ton Sodium Carbonate Produced;
Quality -- E    Emissions Factors Applicability

SCC 30112702
  Industrial Processes > Chemical Manufacturing > Fluorocarbons/Chlorofluorocarbons > Distillation Column
  POLLUTANT Carbon tetrachloride NEI 56235 CAS 56-23-5
    Primary Control / Secondary Control : SULFUR PLANT , TRAY-TYPE GAS ABSORPTION COLUMN ,
  Emission Factor -- 4.600E-2 Lb per Ton Chlorofluorocarbon 12/11 Produced;
Quality -- U    Emissions Factors Applicability

SCC 30112702
  Industrial Processes > Chemical Manufacturing > Fluorocarbons/Chlorofluorocarbons > Distillation Column
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.270E1 Lb per Ton Product Produced;
Quality -- U    Emissions Factors Applicability

SCC 30125325
  Industrial Processes > Chemical Manufacturing > Glycol Ethers > Catalyst: Butanol Mix Tank
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.000E-3 Lb per Ton Glycol Ethers Produced;
Quality -- U    Emissions Factors Applicability

SCC 20200104
  Internal Combustion Engines > Industrial > Distillate Oil (Diesel) > Reciprocating: Cogeneration
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : IMPINGEMENT PLATE SCRUBBER ,
  Emission Factor -- 2.900E0 Lb per 1000 Gallons Distillate Oil (Diesel) Burned;
Quality -- C    Emissions Factors Applicability

SCC 20200104
  Internal Combustion Engines > Industrial > Distillate Oil (Diesel) > Reciprocating: Cogeneration
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.250E1 Lb per 1000 Gallons Distillate Oil (Diesel) Burned;
Quality -- D    Emissions Factors Applicability

SCC 20200105
  Internal Combustion Engines > Industrial > Distillate Oil (Diesel) > Reciprocating: Crankcase Blowby
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : VENTURI SCRUBBER ,
  Emission Factor -- 1.400E0 Lb per 1000 Gallons Distillate Oil (Diesel) Burned;
Quality -- C    Emissions Factors Applicability

SCC 20200201
  Internal Combustion Engines > Industrial > Natural Gas > Turbine
  POLLUTANT Benzo(a)anthracene NEI 56553 CAS 56-55-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.000E-6 Lb per MMBtu Heat Input;
Quality -- U    Emissions Factors Applicability

SCC 20200201
  Internal Combustion Engines > Industrial > Natural Gas > Turbine
  POLLUTANT Naphthalene NEI 91203 CAS 91-20-3
    Primary Control / Secondary Control : VENTURI SCRUBBER , DUST SUPPRESSION - TRAFFIC CONTROL ,
  Emission Factor -- 1.028E-5 Lb per MMBtu Heat Input;
Quality -- U    Emissions Factors Applicability

SCC 20200201
  Internal Combustion Engines > Industrial > Natural Gas > Turbine
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : ALKALINE FLY ASH SCRUBBING ,
  Emission Factor -- 1.300E-1 Lb per MMBtu Fuel Input;
Quality -- A    Emissions Factors Applicability

SCC 20200201
  Internal Combustion Engines > Industrial > Natural Gas > Turbine
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : AMMONIA INJECTION ,
  Emission Factor -- 9.900E-2 Lb per MMBtu Fuel Input;
Quality -- D    Emissions Factors Applicability

SCC 20200201
  Internal Combustion Engines > Industrial > Natural Gas > Turbine
  POLLUTANT Sulfur dioxide NEI SO2 CAS 7446-09-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per MMBtu Fuel Input;
Quality -- B    Emissions Factors Applicability

SCC 20200201
  Internal Combustion Engines > Industrial > Natural Gas > Turbine
  POLLUTANT Toluene NEI 108883 CAS 108-88-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.300E-4 Lb per MMBtu Fuel Input;
Quality -- C    Emissions Factors Applicability

SCC 20200201
  Internal Combustion Engines > Industrial > Natural Gas > Turbine
  POLLUTANT Total organic compounds (TOC) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.100E-2 Lb per MMBtu Fuel Input;
Quality -- B    Emissions Factors Applicability

SCC 20200203
  Internal Combustion Engines > Industrial > Natural Gas > Turbine: Cogeneration
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : ALKALINE FLY ASH SCRUBBING ,
  Emission Factor -- 3.000E-2 Lb per MMBtu Fuel Input;
Quality -- A    Emissions Factors Applicability

SCC 20200203
  Internal Combustion Engines > Industrial > Natural Gas > Turbine: Cogeneration
  POLLUTANT Methane NEI CAS 74-82-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.600E-3 Lb per MMBtu Fuel Input;
Quality -- C    Emissions Factors Applicability

SCC 20200204
  Internal Combustion Engines > Industrial > Natural Gas > Reciprocating: Cogeneration
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.000E1 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- U    Emissions Factors Applicability

SCC 20200207
  Internal Combustion Engines > Industrial > Natural Gas > Reciprocating: Exhaust
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : IMPINGEMENT PLATE SCRUBBER ,
  Emission Factor -- 1.800E1 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- C    Emissions Factors Applicability

SCC 20200252
  Internal Combustion Engines > Industrial > Natural Gas > 2-cycle Lean Burn
  POLLUTANT Acenaphthylene NEI 208968 CAS 208-96-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.170E-6 Lb per MMBtu Fuel Input;
Quality -- C    Emissions Factors Applicability

SCC 20200252
  Internal Combustion Engines > Industrial > Natural Gas > 2-cycle Lean Burn
  POLLUTANT Isobutane NEI CAS 75-28-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.750E-3 Lb per MMBtu Fuel Input;
Quality -- C    Emissions Factors Applicability

SCC 20200252
  Internal Combustion Engines > Industrial > Natural Gas > 2-cycle Lean Burn
  POLLUTANT Methyl alcohol NEI 67561 CAS 67-56-1
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.480E-3 Lb per MMBtu Fuel Input;
Quality -- A    Emissions Factors Applicability

SCC 20200252
  Internal Combustion Engines > Industrial > Natural Gas > 2-cycle Lean Burn
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.940E0 Lb per MMBtu Fuel Input;
Quality -- A    Emissions Factors Applicability    Duplicate factor exists.

SCC 20200254
  Internal Combustion Engines > Industrial > Natural Gas > 4-cycle Lean Burn
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : IMPINGEMENT PLATE SCRUBBER ,
  Emission Factor -- 1.800E1 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- C    Emissions Factors Applicability

SCC 20200254
  Internal Combustion Engines > Industrial > Natural Gas > 4-cycle Lean Burn
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.170E-1 Lb per MMBtu Fuel Input;
Quality -- C    Emissions Factors Applicability    Duplicate factor exists.

SCC 20200254
  Internal Combustion Engines > Industrial > Natural Gas > 4-cycle Lean Burn
  POLLUTANT Chloroform NEI 67663 CAS 67-66-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- < 2.850E-5 Lb per MMBtu Fuel Input;
Quality -- E    Emissions Factors Applicability

SCC 20200254
  Internal Combustion Engines > Industrial > Natural Gas > 4-cycle Lean Burn
  POLLUTANT Cyclopentane NEI CAS 287-92-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.270E-4 Lb per MMBtu Fuel Input;
Quality -- C    Emissions Factors Applicability

SCC 20200254
  Internal Combustion Engines > Industrial > Natural Gas > 4-cycle Lean Burn
  POLLUTANT 1,1-Dichloroethane NEI 75343 CAS 75-34-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- < 2.360E-5 Lb per MMBtu Fuel Input;
Quality -- E    Emissions Factors Applicability

SCC 20200254
  Internal Combustion Engines > Industrial > Natural Gas > 4-cycle Lean Burn
  POLLUTANT 1,3-Dichloropropene NEI 542756 CAS 542-75-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- < 2.640E-5 Lb per MMBtu Fuel Input;
Quality -- E    Emissions Factors Applicability

SCC 20200254
  Internal Combustion Engines > Industrial > Natural Gas > 4-cycle Lean Burn
  POLLUTANT Ethyl chloride NEI 75003 CAS 75-00-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.870E-6 Lb per MMBtu Fuel Input;
Quality -- D    Emissions Factors Applicability

SCC 20200254
  Internal Combustion Engines > Industrial > Natural Gas > 4-cycle Lean Burn
  POLLUTANT Fluoranthene NEI 206440 CAS 206-44-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.110E-6 Lb per MMBtu Fuel Input;
Quality -- C    Emissions Factors Applicability

SCC 20200254
  Internal Combustion Engines > Industrial > Natural Gas > 4-cycle Lean Burn
  POLLUTANT Methyl alcohol NEI 67561 CAS 67-56-1
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.500E-3 Lb per MMBtu Fuel Input;
Quality -- B    Emissions Factors Applicability

SCC 20200254
  Internal Combustion Engines > Industrial > Natural Gas > 4-cycle Lean Burn
  POLLUTANT 1,2,4-Trimethylbenzene NEI CAS 95-63-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.430E-5 Lb per MMBtu Fuel Input;
Quality -- C    Emissions Factors Applicability

SCC 20200401
  Internal Combustion Engines > Industrial > Large Bore Engine > Diesel
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.160E2 Lb per 1000 Gallons Diesel Burned;
Quality -- C    Emissions Factors Applicability

SCC 20200401
  Internal Combustion Engines > Industrial > Large Bore Engine > Diesel
  POLLUTANT Pyrene NEI 129000 CAS 129-00-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.710E-6 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability

SCC 20200402
  Internal Combustion Engines > Industrial > Large Bore Engine > Dual Fuel (Oil/Gas)
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.800E1 Lb per 1000 Horsepower-Hours Work Output;
Quality -- D    Emissions Factors Applicability

SCC 20200402
  Internal Combustion Engines > Industrial > Large Bore Engine > Dual Fuel (Oil/Gas)
  POLLUTANT Styrene NEI 100425 CAS 100-42-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 9.310E-6 Lb per MMBtu Heat Input;
Quality -- U    Emissions Factors Applicability

SCC 20200501
  Internal Combustion Engines > Industrial > Residual/Crude Oil > Reciprocating
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.250E1 Lb per 1000 Gallons Residual/Crude Oil Burned;
Quality -- U    Emissions Factors Applicability

SCC 20200901
  Internal Combustion Engines > Industrial > Kerosene/Naphtha (Jet Fuel) > Turbine
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.107E-2 Lb per MMBtu Fuel Input;
Quality -- U    Emissions Factors Applicability

SCC 20300101
  Internal Combustion Engines > Commercial/Institutional > Distillate Oil (Diesel) > Reciprocating
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : IMPINGEMENT PLATE SCRUBBER ,
  Emission Factor -- 2.900E0 Lb per 1000 Gallons Distillate Oil (Diesel) Burned;
Quality -- C    Emissions Factors Applicability

SCC 20300101
  Internal Combustion Engines > Commercial/Institutional > Distillate Oil (Diesel) > Reciprocating
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.250E1 Lb per 1000 Gallons Distillate Oil (Diesel) Burned;
Quality -- D    Emissions Factors Applicability

SCC 20300102
  Internal Combustion Engines > Commercial/Institutional > Distillate Oil (Diesel) > Turbine
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : ALKALINE FLY ASH SCRUBBING ,
  Emission Factor -- 7.600E-2 Lb per MMBtu Fuel Input;
Quality -- C    Emissions Factors Applicability

SCC 20300102
  Internal Combustion Engines > Commercial/Institutional > Distillate Oil (Diesel) > Turbine
  POLLUTANT Polycyclic aromatic hydrocarbons (PAH) NEI 40 CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.000E-5 Lb per MMBtu Fuel Input;
Quality -- C    Emissions Factors Applicability

SCC 20300201
  Internal Combustion Engines > Commercial/Institutional > Natural Gas > Reciprocating
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.011E1 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- D    Emissions Factors Applicability

SCC 20300202
  Internal Combustion Engines > Commercial/Institutional > Natural Gas > Turbine
  POLLUTANT Methane NEI CAS 74-82-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.600E-3 Lb per MMBtu Fuel Input;
Quality -- C    Emissions Factors Applicability

SCC 20300203
  Internal Combustion Engines > Commercial/Institutional > Natural Gas > Turbine: Cogeneration
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : ALKALINE FLY ASH SCRUBBING ,
  Emission Factor -- 3.000E-2 Lb per MMBtu Fuel Input;
Quality -- A    Emissions Factors Applicability

SCC 20300203
  Internal Combustion Engines > Commercial/Institutional > Natural Gas > Turbine: Cogeneration
  POLLUTANT Propylene oxide NEI 75569 CAS 75-56-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- < 2.900E-5 Lb per MMBtu Fuel Input;
Quality -- D    Emissions Factors Applicability

SCC 20300205
  Internal Combustion Engines > Commercial/Institutional > Natural Gas > Reciprocating: Crankcase Blowby
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : IMPINGEMENT PLATE SCRUBBER ,
  Emission Factor -- 1.800E1 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- C    Emissions Factors Applicability

SCC 20300205
  Internal Combustion Engines > Commercial/Institutional > Natural Gas > Reciprocating: Crankcase Blowby
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : VENTURI SCRUBBER ,
  Emission Factor -- 9.100E0 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- C    Emissions Factors Applicability

SCC 20300206
  Internal Combustion Engines > Commercial/Institutional > Natural Gas > Reciprocating: Evaporative Losses (Fuel Delivery System)
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : VENTURI SCRUBBER ,
  Emission Factor -- 9.100E0 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- C    Emissions Factors Applicability

SCC 20300301
  Internal Combustion Engines > Commercial/Institutional > Gasoline > Reciprocating
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.260E1 Lb per 1000 Gallons Gasoline Burned;
Quality -- D    Emissions Factors Applicability

SCC 20300701
  Internal Combustion Engines > Commercial/Institutional > Digester Gas > Turbine
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.477E-2 Lb per MMBtu Fuel Input;
Quality -- E    Emissions Factors Applicability

SCC 20300801
  Internal Combustion Engines > Commercial/Institutional > Landfill Gas > Turbine
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.400E-1 Lb per MMBtu Fuel Input;
Quality -- A    Emissions Factors Applicability

SCC 20400302
  Internal Combustion Engines > Engine Testing > Turbine > Diesel/Kerosene
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : ALKALINE FLY ASH SCRUBBING ,
  Emission Factor -- 3.870E-3 Lb per MMBtu Fuel Input;
Quality -- U    Emissions Factors Applicability

SCC 30100105
  Industrial Processes > Chemical Manufacturing > Adipic Acid > Adipic Acid Refining
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.000E-1 Lb per Ton Adipic Acid Produced;
Quality -- B    Emissions Factors Applicability

SCC 30100106
  Industrial Processes > Chemical Manufacturing > Adipic Acid > Drying, Loading, and Storage
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.200E-2 Lb per Ton Adipic Acid Produced;
Quality -- B    Emissions Factors Applicability

SCC 30100305
  Industrial Processes > Chemical Manufacturing > Ammonia Production > Feedstock Desulfurization
  POLLUTANT Sulfur dioxide NEI SO2 CAS 7446-09-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.760E-2 Lb per Ton Ammonia Produced;
Quality -- E    Emissions Factors Applicability

SCC 30100504
  Industrial Processes > Chemical Manufacturing > Carbon Black Production > Oil Furnace Process: Main Process Vent
  POLLUTANT Methane NEI CAS 74-82-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E1 Lb per Ton Carbon Black Produced;
Quality -- C    Emissions Factors Applicability

SCC 30100504
  Industrial Processes > Chemical Manufacturing > Carbon Black Production > Oil Furnace Process: Main Process Vent
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.530E0 Lb per Ton Carbon Black Produced;
Quality -- C    Emissions Factors Applicability

SCC 30100603
  Industrial Processes > Chemical Manufacturing > Charcoal Manufacturing > Batch Kiln
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.900E2 Lb per Ton Charcoal Produced;
Quality -- E    Emissions Factors Applicability

SCC 30101302
  Industrial Processes > Chemical Manufacturing > Nitric Acid > Absorber Tail Gas (Post-1970 Facilities)
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.100E0 Lb per Ton Pure Acid Produced;
Quality -- E    Emissions Factors Applicability    Duplicate factor exists.

SCC 30101602
  Industrial Processes > Chemical Manufacturing > Phosphoric Acid: Wet Process > Gypsum Pond
  POLLUTANT Hydrogen fluoride NEI 7664393 CAS 7664-39-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.200E-1 Lb per Ton Phosphate Rock Handled;
Quality -- U    Emissions Factors Applicability

SCC 30101807
  Industrial Processes > Chemical Manufacturing > Plastics Production > General: Polyethylene (High Density)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.600E-1 Lb per Ton Product Produced;
Quality -- U    Emissions Factors Applicability

SCC 30101817
  Industrial Processes > Chemical Manufacturing > Plastics Production > General
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.600E-2 Lb per Ton Product Produced;
Quality -- C    Emissions Factors Applicability    Duplicate factor exists.

SCC 30101842
  Industrial Processes > Chemical Manufacturing > Plastics Production > Melamine Resins
  POLLUTANT Formaldehyde NEI 50000 CAS 50-00-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.000E-1 Lb per Ton 37% Formaldehyde Solution Used;
Quality -- U    Emissions Factors Applicability

SCC 30101899
  Industrial Processes > Chemical Manufacturing > Plastics Production > Others Not Specified
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.460E0 - 7.800E0 Lb per Ton Product Produced;
Quality -- C    Emissions Factors Applicability    Duplicate factor exists.

SCC 30101899
  Industrial Processes > Chemical Manufacturing > Plastics Production > Others Not Specified
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.000E-2 Lb per Ton Product Produced;
Quality -- C    Emissions Factors Applicability    Duplicate factor exists.

SCC 30101899
  Industrial Processes > Chemical Manufacturing > Plastics Production > Others Not Specified
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.200E-1 - 7.200E0 Lb per Ton Product Produced;
Quality -- C    Emissions Factors Applicability    Duplicate factor exists.

SCC 30101904
  Industrial Processes > Chemical Manufacturing > Phthalic Anhydride > o-Xylene Oxidation: Distillation
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.370E1 Lb per Ton Phthalic Anhydride Produced;
Quality -- B    Emissions Factors Applicability

SCC 30101907
  Industrial Processes > Chemical Manufacturing > Phthalic Anhydride > Naphthalene Oxidation: Distillation
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.000E1 Lb per Ton Phthalic Anhydride Produced;
Quality -- B    Emissions Factors Applicability

SCC 30102106
  Industrial Processes > Chemical Manufacturing > Sodium Carbonate > Rotary Soda Ash Dryers
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.400E1 Lb per Ton Sodium Carbonate Produced;
Quality -- B    Emissions Factors Applicability

SCC 30102114
  Industrial Processes > Chemical Manufacturing > Sodium Carbonate > Rotary Dryer: Steam Tube
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.700E1 Lb per Ton Sodium Carbonate Produced;
Quality -- U    Emissions Factors Applicability

SCC 30102126
  Industrial Processes > Chemical Manufacturing > Sodium Carbonate > Sesquicarbonate Process: Fluid-bed Calciner
  POLLUTANT PM, primary NEI PM-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.300E0 Lb per Ton Sodium Carbonate Produced;
Quality -- D    Emissions Factors Applicability

SCC 30102127
  Industrial Processes > Chemical Manufacturing > Sodium Carbonate > Soda Ash Screening
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CONSERVATION VENT , ROTOCLONE ,
  Emission Factor -- 1.900E-2 Lb per Ton Sodium Carbonate Produced;
Quality -- E    Emissions Factors Applicability

SCC 30102310
  Industrial Processes > Chemical Manufacturing > Sulfuric Acid (Contact Process) > Absorber/@ 97.0% Conversion
  POLLUTANT Sulfur dioxide NEI SO2 CAS 7446-09-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.000E1 Lb per Ton 100% Sulfuric Acid Produced;
Quality -- E    Emissions Factors Applicability

SCC 30102312
  Industrial Processes > Chemical Manufacturing > Sulfuric Acid (Contact Process) > Absorber/@ 96.0% Conversion
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.000E-3 Lb per Ton 100% Sulfuric Acid Produced;
Quality -- U    Emissions Factors Applicability

SCC 30102318
  Industrial Processes > Chemical Manufacturing > Sulfuric Acid (Contact Process) > Absorber/@ 93.0% Conversion
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.000E-3 Lb per Ton 100% Sulfuric Acid Produced;
Quality -- U    Emissions Factors Applicability

SCC 30102601
  Industrial Processes > Chemical Manufacturing > Synthetic Rubber (Manufacturing Only) > General
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.200E0 Lb per Ton Product Produced;
Quality -- B    Emissions Factors Applicability

SCC 30102613
  Industrial Processes > Chemical Manufacturing > Synthetic Rubber (Manufacturing Only) > Monomer Recovery: Absorber Vent
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.200E-1 Lb per Ton Product Produced;
Quality -- B    Emissions Factors Applicability

SCC 30102722
  Industrial Processes > Chemical Manufacturing > Ammonium Nitrate Production > Prilling Tower: Low Density
  POLLUTANT Ammonia NEI NH3 CAS 7664-41-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.600E-1 Lb per Ton Ammonium Nitrate Produced;
Quality -- A    Emissions Factors Applicability

SCC 30102804
  Industrial Processes > Chemical Manufacturing > Normal Superphosphates > Rock Feeder System
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E-2 Lb per Ton P2O5 Produced;
Quality -- A    Emissions Factors Applicability

SCC 30102805
  Industrial Processes > Chemical Manufacturing > Normal Superphosphates > Mixer/Den
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : SECONDARY SEAL ON FLOATING ROOF TANK ,
  Emission Factor -- 5.200E-1 Lb per Ton P2O5 Produced;
Quality -- E    Emissions Factors Applicability

SCC 30102805
  Industrial Processes > Chemical Manufacturing > Normal Superphosphates > Mixer/Den
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.700E-1 Lb per Ton P2O5 Produced;
Quality -- A    Emissions Factors Applicability

SCC 30102805
  Industrial Processes > Chemical Manufacturing > Normal Superphosphates > Mixer/Den
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : SECONDARY SEAL ON FLOATING ROOF TANK ,
  Emission Factor -- 4.400E-1 Lb per Ton P2O5 Produced;
Quality -- E    Emissions Factors Applicability

SCC 30102806
  Industrial Processes > Chemical Manufacturing > Normal Superphosphates > Curing/Building
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.100E0 Lb per Ton P2O5 Produced;
Quality -- E    Emissions Factors Applicability

SCC 30102906
  Industrial Processes > Chemical Manufacturing > Triple Superphosphate > Granulator: Reactor/Dryer
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E-2 Lb per Ton P2O5 Produced;
Quality -- A    Emissions Factors Applicability

SCC 30102922
  Industrial Processes > Chemical Manufacturing > Triple Superphosphate > Curing
  POLLUTANT Fluoride NEI CAS 16984-48-8
    Primary Control / Secondary Control : SECONDARY SEAL ON FLOATING ROOF TANK ,
  Emission Factor -- 4.000E-2 Lb per Ton Material Produced;
Quality -- E    Emissions Factors Applicability

SCC 30103104
  Industrial Processes > Chemical Manufacturing > Terephthalic Acid/Dimethyl Terephthalate > Distillation and Recovery Vent
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.200E0 Lb per Ton Material Produced;
Quality -- C    Emissions Factors Applicability

SCC 30103105
  Industrial Processes > Chemical Manufacturing > Terephthalic Acid/Dimethyl Terephthalate > Product Transfer Vent
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.000E0 Lb per Ton Material Produced;
Quality -- C    Emissions Factors Applicability

SCC 30103501
  Industrial Processes > Chemical Manufacturing > Inorganic Pigments > TiO2 Sulfate Process: Calciner
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.760E1 Lb per Ton Material Produced;
Quality -- U    Emissions Factors Applicability

SCC 30104012
  Industrial Processes > Chemical Manufacturing > Urea Production > Rotary Drum Cooler
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.100E-1 Lb per Ton Urea Produced;
Quality -- U    Emissions Factors Applicability

SCC 30104202
  Industrial Processes > Chemical Manufacturing > Lead Alkyl Manufacturing (Sodium/Lead Alloy Process) > Process Vents: Tetraethyl Lead
  POLLUTANT Lead NEI 7439921 CAS 7439-92-1
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.000E0 Lb per Ton Material Produced;
Quality -- B    Emissions Factors Applicability

SCC 30110002
  Industrial Processes > Chemical Manufacturing > Maleic Anhydride > Product Recovery Absorber
  POLLUTANT Benzene NEI 71432 CAS 71-43-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.700E1 Lb per 1000 Pounds Maleic Anhydride Produced;
Quality -- U    Emissions Factors Applicability

SCC 30110003
  Industrial Processes > Chemical Manufacturing > Maleic Anhydride > Vacuum System Vent
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.000E-1 Lb per Ton Maleic Anhydride Produced;
Quality -- U    Emissions Factors Applicability

SCC 30112501
  Industrial Processes > Chemical Manufacturing > Chlorine Derivatives > Ethylene Dichloride via Oxychlorination
  POLLUTANT Carbon tetrachloride NEI 56235 CAS 56-23-5
    Primary Control / Secondary Control : MULTIPLE CYCLONE W/O FLY ASH REINJECTION ,
  Emission Factor -- 4.800E-2 Lb per Ton Product Produced;
Quality -- U    Emissions Factors Applicability

SCC 30112512
  Industrial Processes > Chemical Manufacturing > Chlorine Derivatives > Chloromethanes: Drying Bed Regeneration Vent
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.000E-1 Lb per Ton Product Produced;
Quality -- U    Emissions Factors Applicability

SCC 30112520
  Industrial Processes > Chemical Manufacturing > Chlorine Derivatives > Perchloroethylene: General
  POLLUTANT Perchloroethylene NEI 127184 CAS 127-18-4
    Primary Control / Secondary Control : SODIUM CARBONATE SCRUBBING ,
  Emission Factor -- 5.200E-2 Lb per Ton-Year Perchloroethylene Production Capacity;
Quality -- U    Emissions Factors Applicability    Duplicate factor exists.

SCC 30112524
  Industrial Processes > Chemical Manufacturing > Chlorine Derivatives > Perchloroethylene: Fugitive Emissions
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.650E5 Lb per Each-Year Process Unit Operating;
Quality -- U    Emissions Factors Applicability

SCC 30112528
  Industrial Processes > Chemical Manufacturing > Chlorine Derivatives > Trichloroethane: Distillation Column Vent
  POLLUTANT Ethylene dichloride NEI 107062 CAS 107-06-2
    Primary Control / Secondary Control : MULTIPLE CYCLONE W/ FLY ASH REINJECTION ,
  Emission Factor -- 2.000E-3 Lb per Ton Product Produced;
Quality -- U    Emissions Factors Applicability    Duplicate factor exists.

SCC 30112528
  Industrial Processes > Chemical Manufacturing > Chlorine Derivatives > Trichloroethane: Distillation Column Vent
  POLLUTANT Vinyl chloride NEI 75014 CAS 75-01-4
    Primary Control / Secondary Control : MULTIPLE CYCLONE W/ FLY ASH REINJECTION ,
  Emission Factor -- 2.000E-4 Lb per Ton Product Produced;
Quality -- U    Emissions Factors Applicability

SCC 30112531
  Industrial Processes > Chemical Manufacturing > Chlorine Derivatives > Trichloroethylene: Distillation Unit
  POLLUTANT Vinylidene chloride NEI 75354 CAS 75-35-4
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.120E-1 Lb per Ton Perc & Trichloroethylene Produced;
Quality -- U    Emissions Factors Applicability

SCC 30112540
  Industrial Processes > Chemical Manufacturing > Chlorine Derivatives > Vinyl Chloride: General
  POLLUTANT Perchloroethylene NEI 127184 CAS 127-18-4
    Primary Control / Secondary Control : OTHER POLLUTION PREVENTION TECHNIQUE ,
  Emission Factor -- 1.000E-4 Lb per Ton Material Produced;
Quality -- U    Emissions Factors Applicability

SCC 30112542
  Industrial Processes > Chemical Manufacturing > Chlorine Derivatives > Vinyl Chloride: HCl Recovery
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.000E-1 Lb per Ton Product Produced;
Quality -- U    Emissions Factors Applicability

SCC 30113205
  Industrial Processes > Chemical Manufacturing > Organic Acid Manufacturing > Acetic Acid via Butane
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.000E-2 Lb per Ton Material Produced;
Quality -- U    Emissions Factors Applicability

SCC 30113301
  Industrial Processes > Chemical Manufacturing > Acetic Anhydride > General
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 9.900E0 Lb per Ton Acetic Anhydride Produced;
Quality -- U    Emissions Factors Applicability

SCC 30115312
  Industrial Processes > Chemical Manufacturing > Butadiene > Houdry Process: Dehydrogenation Reactor
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.600E0 Lb per Ton Butadiene Produced;
Quality -- U    Emissions Factors Applicability

SCC 30115603
  Industrial Processes > Chemical Manufacturing > Cumene > Aluminum Chloride Catalyst Process: Catalyst Mix Tank Scrubber Vent
  POLLUTANT Benzene NEI 71432 CAS 71-43-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.200E-1 Lb per Ton Cumene Produced;
Quality -- U    Emissions Factors Applicability

SCC 30115609
  Industrial Processes > Chemical Manufacturing > Cumene > Solid Phosphoric Acid Catalyst Process: Cumene Distillation Sys. Vent
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E-2 Lb per Ton Cumene Produced;
Quality -- U    Emissions Factors Applicability

SCC 30115822
  Industrial Processes > Chemical Manufacturing > Cyclohexanone/Cyclohexanol > Distillation Vent
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.200E-1 Lb per Ton Product Produced;
Quality -- U    Emissions Factors Applicability

SCC 30116703
  Industrial Processes > Chemical Manufacturing > Vinyl Acetate > CO2 Purge Vent
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E-1 Lb per Ton Vinyl Acetate Produced;
Quality -- U    Emissions Factors Applicability

SCC 30118103
  Industrial Processes > Chemical Manufacturing > Toluene Diisocyanate > Nitration Reactor
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E-2 Lb per Ton Toluene Diisocyanate Produced;
Quality -- U    Emissions Factors Applicability

SCC 30119002
  Industrial Processes > Chemical Manufacturing > Methyl Methacrylate > Acetone Cyanohydrin Reactor Off-gas
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.000E-2 Lb per Ton Methyl Methacrylate Produced;
Quality -- U    Emissions Factors Applicability

SCC 30119502
  Industrial Processes > Chemical Manufacturing > Nitrobenzene > Reactor and Separator Vent
  POLLUTANT Benzene NEI 71432 CAS 71-43-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.920E0 Lb per Ton Nitrobenzene Produced;
Quality -- U    Emissions Factors Applicability

SCC 30119503
  Industrial Processes > Chemical Manufacturing > Nitrobenzene > Acid Stripper Vent
  POLLUTANT Benzene NEI 71432 CAS 71-43-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.400E-1 Lb per Ton Nitrobenzene Produced;
Quality -- U    Emissions Factors Applicability

SCC 30119749
  Industrial Processes > Chemical Manufacturing > Butylene, Ethylene, Propylene, Olefin Production > Ethylene: Fugitive Emissions
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.950E5 Lb per Each-Year Process Unit Operating;
Quality -- U    Emissions Factors Applicability

SCC 30120206
  Industrial Processes > Chemical Manufacturing > Phenol > Phenol Distillation Column
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.600E0 Lb per Ton Phenol Produced;
Quality -- U    Emissions Factors Applicability

SCC 30120211
  Industrial Processes > Chemical Manufacturing > Phenol > CHP Cleavage Vent
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 9.500E-1 Lb per Ton Phenol Produced;
Quality -- U    Emissions Factors Applicability

SCC 30120504
  Industrial Processes > Chemical Manufacturing > Propylene Oxide > Saponification Column Vent
  POLLUTANT Propylene oxide NEI 75569 CAS 75-56-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.800E-2 Lb per Ton Propylene Oxide Produced;
Quality -- U    Emissions Factors Applicability

SCC 30120521
  Industrial Processes > Chemical Manufacturing > Propylene Oxide > Oxidation Reactor Scrubber Vent
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.500E0 Lb per Ton Propylene Oxide Produced;
Quality -- U    Emissions Factors Applicability

SCC 30121002
  Industrial Processes > Chemical Manufacturing > Caprolactum (Use 3-01-130 for Ammonium Sulfate By-product Production) > Cyclohexanone Purification Vent
  POLLUTANT Benzene NEI 71432 CAS 71-43-2
    Primary Control / Secondary Control : SPRAY SCREEN ,
  Emission Factor -- 3.200E-2 Lb per Ton Product Produced;
Quality -- U    Emissions Factors Applicability

SCC 30121123
  Industrial Processes > Chemical Manufacturing > Linear Alkylbenzene > HCl Absorber Vent
  POLLUTANT Benzene NEI 71432 CAS 71-43-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E-1 Lb per Ton Linear Alkylbenzene Produced;
Quality -- U    Emissions Factors Applicability

SCC 30125406
  Industrial Processes > Chemical Manufacturing > Nitriles, Acrylonitrile, Adiponitrile Production > Absorber Vent: Normal
  POLLUTANT Acrylonitrile NEI 107131 CAS 107-13-1
    Primary Control / Secondary Control : MULTIPLE CYCLONE W/ FLY ASH REINJECTION ,
  Emission Factor -- 4.000E-3 Lb per Ton Acrylonitrile Produced;
Quality -- U    Emissions Factors Applicability

SCC 30125406
  Industrial Processes > Chemical Manufacturing > Nitriles, Acrylonitrile, Adiponitrile Production > Absorber Vent: Normal
  POLLUTANT Hydrogen cyanide NEI 74908 CAS 74-90-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.000E-1 Lb per Ton Acrylonitrile Produced;
Quality -- U    Emissions Factors Applicability

SCC 30300103
  Industrial Processes > Primary Metal Production > Aluminum Ore (Electro-reduction) > Vertical Stud Soderberg Cell
  POLLUTANT Fluoride NEI CAS 16984-48-8
    Primary Control / Secondary Control : CONSERVATION VENT ,
  Emission Factor -- 4.000E-1 Lb per Ton Molten Aluminum Produced;
Quality -- A    Emissions Factors Applicability    Duplicate factor exists.

SCC 30300308
  Industrial Processes > Primary Metal Production > By-product Coke Manufacturing > Oven/Door Leaks
  POLLUTANT Benzo(a)pyrene NEI 50328 CAS 50-32-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.500E1 mg per Megagram Coal Burned;
Quality -- U    Emissions Factors Applicability

SCC 30300908
  Industrial Processes > Primary Metal Production > Steel Manufacturing (See 3-03-015 for Integrated Iron & Steel MACT) > Electric Arc Furnace: Carbon Steel (Stack)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.204E1 Lb per Ton Material Produced;
Quality -- C    Emissions Factors Applicability

SCC 30400304
  Industrial Processes > Secondary Metal Production > Grey Iron Foundries > Electric Arc Furnace
  POLLUTANT Manganese NEI 7439965 CAS 7439-96-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.800E-1 Lb per Ton Iron Produced;
Quality -- U    Emissions Factors Applicability

SCC 30400409
  Industrial Processes > Secondary Metal Production > Lead > Casting
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.000E-2 Lb per Ton Lead Cast;
Quality -- C    Emissions Factors Applicability

SCC 30125417
  Industrial Processes > Chemical Manufacturing > Nitriles, Acrylonitrile, Adiponitrile Production > Cyanide Synthesis
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.580E1 Lb per Ton Product Produced;
Quality -- U    Emissions Factors Applicability

SCC 30130106
  Industrial Processes > Chemical Manufacturing > Chlorobenzene > Vacuum System Vent
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 9.000E-1 Lb per Ton Chlorobenzene Produced;
Quality -- U    Emissions Factors Applicability

SCC 30130114
  Industrial Processes > Chemical Manufacturing > Chlorobenzene > Secondary Emissions: Handling and Disposal of Wastewater
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E-2 Lb per Ton Chlorobenzene Produced;
Quality -- U    Emissions Factors Applicability

SCC 30190002
  Industrial Processes > Chemical Manufacturing > Fuel Fired Equipment > Residual Oil: Process Heaters
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.800E-1 Lb per 1000 Gallons Residual Oil Burned;
Quality -- A    Emissions Factors Applicability

SCC 30190012
  Industrial Processes > Chemical Manufacturing > Fuel Fired Equipment > Residual Oil: Incinerators
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.600E-1 Lb per 1000 Gallons Residual Oil Burned;
Quality -- U    Emissions Factors Applicability

SCC 30190099
  Industrial Processes > Chemical Manufacturing > Fuel Fired Equipment > Specify in Comments Field
  POLLUTANT Hydrogen sulfide NEI 7783064 CAS 7783-06-4
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.000E0 Lb per Ton Carbon Black Produced;
Quality -- C    Emissions Factors Applicability

SCC 30200220
  Industrial Processes > Food and Agriculture > Coffee Roasting > Indirect-fired Batch Roaster -Natural Gas (incl combustion emiss)
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : MULTIPLE CYCLONE W/O FLY ASH REINJECTION ,
  Emission Factor -- 5.500E-1 Lb per Ton Beans Fed;
Quality -- D    Emissions Factors Applicability

SCC 30200221
  Industrial Processes > Food and Agriculture > Coffee Roasting > Indirect-fired Continuous Roaster -Natural Gas (incl combustion emiss)
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : MULTIPLE CYCLONE W/O FLY ASH REINJECTION ,
  Emission Factor -- 9.800E-2 Lb per Ton Beans Fed;
Quality -- D    Emissions Factors Applicability

SCC 30200403
  Industrial Processes > Food and Agriculture > Cotton Ginning > Master Trash Fan(incl Stick&Burr Mach/Gin Stand/Extr'r Feed/Batt Cond)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.000E-2 Lb per Bale Cotton Processed;
Quality -- C    Emissions Factors Applicability

SCC 30200435
  Industrial Processes > Food and Agriculture > Cotton Ginning > Mote Fan
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CONDENSER ,
  Emission Factor -- 1.300E-1 Lb per Bale Cotton Processed;
Quality -- D    Emissions Factors Applicability

SCC 30200507
  Industrial Processes > Food and Agriculture > Feed and Grain Terminal Elevators > Removal from Bins (Tunnel Belt)
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.400E0 Lb per Ton Grain Processed;
Quality -- B    Emissions Factors Applicability

SCC 30200512
  Industrial Processes > Food and Agriculture > Feed and Grain Terminal Elevators > Country Elevators: General
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.020E1 Lb per Ton Grain Shipped or Received;
Quality -- U    Emissions Factors Applicability

SCC 30200560
  Industrial Processes > Food and Agriculture > Feed and Grain Terminal Elevators > Loading (Shipping) into Trucks (unspecified type)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.900E-2 Lb per Ton Grain Processed;
Quality -- E    Emissions Factors Applicability

SCC 30200563
  Industrial Processes > Food and Agriculture > Feed and Grain Terminal Elevators > Loading (Shipping) into Railcars
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.700E-2 Lb per Ton Grain Processed;
Quality -- E    Emissions Factors Applicability

SCC 30200564
  Industrial Processes > Food and Agriculture > Feed and Grain Terminal Elevators > Loading (Shipping) into Barges
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.000E-3 Lb per Ton Grain Processed;
Quality -- E    Emissions Factors Applicability

SCC 30200565
  Industrial Processes > Food and Agriculture > Feed and Grain Terminal Elevators > Loading (Shipping) into Ships
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.800E-2 Lb per Ton Grain Processed;
Quality -- E    Emissions Factors Applicability

SCC 30200608
  Industrial Processes > Food and Agriculture > Feed and Grain Country Elevators > Elevator Legs (Headhouse)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.300E-1 Lb per Ton Grain Processed;
Quality -- B    Emissions Factors Applicability

SCC 30200708
  Industrial Processes > Food and Agriculture > Grain Millings > Barley Malting: Grain Receiving
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : DUCT SORBENT INJECTION ,
  Emission Factor -- 1.600E-2 Lb per Ton Grain Processed;
Quality -- E    Emissions Factors Applicability

SCC 30200742
  Industrial Processes > Food and Agriculture > Grain Millings > Dry Corn Milling: Grain Drying
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.500E-2 Lb per Ton Grain Processed;
Quality -- E    Emissions Factors Applicability    Duplicate factor exists.

SCC 30200760
  Industrial Processes > Food and Agriculture > Grain Millings > Oat: General
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.900E-2 Lb per Ton Grain Received;
Quality -- E    Emissions Factors Applicability    Duplicate factor exists.

SCC 30200816
  Industrial Processes > Food and Agriculture > Feed Manufacture > Pellet Cooler
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CONDENSER ,
  Emission Factor -- 7.500E-2 Lb per Ton Grain Processed;
Quality -- E    Emissions Factors Applicability

SCC 30200817
  Industrial Processes > Food and Agriculture > Feed Manufacture > Grain Milling: Hammermill
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- 1.200E-2 Lb per Ton Grain Processed;
Quality -- E    Emissions Factors Applicability

SCC 30200930
  Industrial Processes > Food and Agriculture > Beer Production > Brewers Grain Dryer: Natural Gas-fired
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.300E-1 Lb per Ton Dried Grain Produced;
Quality -- D    Emissions Factors Applicability

SCC 30201001
  Industrial Processes > Food and Agriculture > Distilled Spirits > Grain Handling** (see 3-02-006-05)
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.000E0 Lb per Ton Grain Processed;
Quality -- E    Emissions Factors Applicability

SCC 30201017
  Industrial Processes > Food and Agriculture > Distilled Spirits > Whiskey: Aging - Evaporation Loss
  POLLUTANT Ethyl alcohol NEI CAS 64-17-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.900E0 Lb per Barrel Grain Processed;
Quality -- E    Emissions Factors Applicability

SCC 30201105
  Industrial Processes > Food and Agriculture > Wines, Brandy, and Brandy Spirits > Wine Fermentation - White Wine
  POLLUTANT Hydrogen sulfide NEI 7783064 CAS 7783-06-4
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.400E-3 Lb per 1000 Gallons Fermented Juice Produced;
Quality -- E    Emissions Factors Applicability

SCC 30201106
  Industrial Processes > Food and Agriculture > Wines, Brandy, and Brandy Spirits > Wine Fermentation - Red Wine
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : LOW SOLVENT COATINGS ,
  Emission Factor -- 1.700E-1 Lb per 1000 Gallons Fermented Juice Produced;
Quality -- C    Emissions Factors Applicability

SCC 30201112
  Industrial Processes > Food and Agriculture > Wines, Brandy, and Brandy Spirits > Fugitive Emissions: Pomace Press - Red Wine
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.000E-2 Lb per 1000 Gallons Fermented Juice Produced;
Quality -- E    Emissions Factors Applicability

SCC 30201203
  Industrial Processes > Food and Agriculture > Fish Processing > Dryers **
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.000E-1 Lb per Ton Fish Scrap Processed;
Quality -- U    Emissions Factors Applicability

SCC 30201205
  Industrial Processes > Food and Agriculture > Fish Processing > Steam Tube Dryer
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.050E0 Lb per Ton Fish Scrap Processed;
Quality -- C    Emissions Factors Applicability

SCC 30400211
  Industrial Processes > Secondary Metal Production > Copper > Charge with Insulated Copper Wire: Cupolas
  POLLUTANT Copper NEI CAS 7440-50-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.200E0 Lb per Ton Material Processed;
Quality -- U    Emissions Factors Applicability

SCC 30400212
  Industrial Processes > Secondary Metal Production > Copper > Charge with Scrap Copper And Brass: Cupolas
  POLLUTANT Copper NEI CAS 7440-50-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.600E-1 Lb per Ton Material Processed;
Quality -- U    Emissions Factors Applicability

SCC 30400407
  Industrial Processes > Secondary Metal Production > Lead > Pot Furnace Heater: Natural Gas
  POLLUTANT Sulfur oxides (SOx) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E-1 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- U    Emissions Factors Applicability

SCC 30400408
  Industrial Processes > Secondary Metal Production > Lead > Barton Process Reactor (Oxidation Kettle)
  POLLUTANT Lead NEI 7439921 CAS 7439-92-1
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.400E-1 Lb per Ton Lead Oxide Produced;
Quality -- U    Emissions Factors Applicability

SCC 30500101
  Industrial Processes > Mineral Products > Asphalt Roofing Manufacture > Asphalt Blowing: Saturant (Use 3-05-050-10 for MACT)
  POLLUTANT Polycyclic organic matter (POM) NEI 246 CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.040E-2 Lb per Ton Asphalt Blown;
Quality -- U    Emissions Factors Applicability

SCC 30201304
  Industrial Processes > Food and Agriculture > Meat Smokehouses > Continuous Smokehouse: Smoke Zone
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : SECONDARY SEAL ON FLOATING ROOF TANK , SCREENED DRUMS OR CAGES ,
  Emission Factor -- 2.900E1 Lb per Ton Sawdust Used;
Quality -- D    Emissions Factors Applicability

SCC 30201304
  Industrial Processes > Food and Agriculture > Meat Smokehouses > Continuous Smokehouse: Smoke Zone
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.600E1 Lb per Ton Sawdust Used;
Quality -- D    Emissions Factors Applicability

SCC 30201408
  Industrial Processes > Food and Agriculture > Starch Manufacturing > Starch Bulk Loadout
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : DUCT SORBENT INJECTION ,
  Emission Factor -- 4.900E-4 Lb per Ton Starch Loaded;
Quality -- E    Emissions Factors Applicability

SCC 30201601
  Industrial Processes > Food and Agriculture > Sugar Beet Processing > Pulp Dryer : Coal-fired
  POLLUTANT Acenaphthylene NEI 208968 CAS 208-96-8
    Primary Control / Secondary Control : SECONDARY SEAL ON FLOATING ROOF TANK ,
  Emission Factor -- 1.700E-6 Lb per Ton Pressed Wet Pulp Fed;
Quality -- E    Emissions Factors Applicability

SCC 30201601
  Industrial Processes > Food and Agriculture > Sugar Beet Processing > Pulp Dryer : Coal-fired
  POLLUTANT Acetaldehyde NEI 75070 CAS 75-07-0
    Primary Control / Secondary Control : SECONDARY SEAL ON FLOATING ROOF TANK ,
  Emission Factor -- 1.500E-2 Lb per Ton Pressed Wet Pulp Fed;
Quality -- E    Emissions Factors Applicability

SCC 30201601
  Industrial Processes > Food and Agriculture > Sugar Beet Processing > Pulp Dryer : Coal-fired
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.000E-1 Lb per Ton Raw Beets Processed;
Quality -- U    Emissions Factors Applicability

SCC 30201621
  Industrial Processes > Food and Agriculture > Sugar Beet Processing > First Carbonation Tank
  POLLUTANT Phenanthrene NEI 85018 CAS 85-01-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.400E-6 Lb per 1000 Gallons Raw Juice Processed;
Quality -- D    Emissions Factors Applicability

SCC 30201622
  Industrial Processes > Food and Agriculture > Sugar Beet Processing > Second Carbonation Tank
  POLLUTANT Crotonaldehyde NEI 123739 CAS 123-73-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.000E-5 Lb per 1000 Gallons Raw Juice Processed;
Quality -- E    Emissions Factors Applicability

SCC 30201641
  Industrial Processes > Food and Agriculture > Sugar Beet Processing > First Effect Evaporator Vent
  POLLUTANT Benzyl alcohol NEI CAS 100-51-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.800E-7 Lb per 1000 Gallons Thin Juice Processed;
Quality -- E    Emissions Factors Applicability

SCC 30203020
  Industrial Processes > Food and Agriculture > Dairy Products > Cheese Dryer
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 7.300E-1 Lb per Ton Dry Product Produced;
Quality -- D    Emissions Factors Applicability

SCC 30203107
  Industrial Processes > Food and Agriculture > Export Grain Elevators > Removal from Bins (Tunnel Belt)
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.400E0 Lb per Ton Grain Processed;
Quality -- B    Emissions Factors Applicability

SCC 30203407
  Industrial Processes > Food and Agriculture > Baker's Yeast Manufacturing - Dry Yeast > Trade Fermentor (F7 Stage)
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E0 Lb per Ton Yeast from F7 Produced;
Quality -- E    Emissions Factors Applicability

SCC 30203811
  Industrial Processes > Food and Agriculture > Animal/Poultry Rendering > Blood Dryer: Natural Gas Direct Fired
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : STEAM OR WATER INJECTION , CONSERVATION VENT ,
  Emission Factor -- 1.220E0 Lb per Ton Dried Blood Meal Produced;
Quality -- E    Emissions Factors Applicability

SCC 30290002
  Industrial Processes > Food and Agriculture > Fuel Fired Equipment > Residual Oil: Process Heaters
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.800E-1 Lb per 1000 Gallons Residual Oil Burned;
Quality -- A    Emissions Factors Applicability

SCC 30300101
  Industrial Processes > Primary Metal Production > Aluminum Ore (Electro-reduction) > Prebaked Reduction Cell
  POLLUTANT Fluoride NEI CAS 16984-48-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.000E1 Lb per Ton Molten Aluminum Produced;
Quality -- A    Emissions Factors Applicability    Duplicate factor exists.

SCC 30300101
  Industrial Processes > Primary Metal Production > Aluminum Ore (Electro-reduction) > Prebaked Reduction Cell
  POLLUTANT Fluoride NEI CAS 16984-48-8
    Primary Control / Secondary Control : CATALYTIC REDUCTION ,
  Emission Factor -- 1.400E0 Lb per Ton Molten Aluminum Produced;
Quality -- A    Emissions Factors Applicability    Duplicate factor exists.

SCC 30300101
  Industrial Processes > Primary Metal Production > Aluminum Ore (Electro-reduction) > Prebaked Reduction Cell
  POLLUTANT Fluoride NEI CAS 16984-48-8
    Primary Control / Secondary Control : OVERFIRE AIR ,
  Emission Factor -- 2.000E-1 Lb per Ton Molten Aluminum Produced;
Quality -- A    Emissions Factors Applicability    Duplicate factor exists.

SCC 30300101
  Industrial Processes > Primary Metal Production > Aluminum Ore (Electro-reduction) > Prebaked Reduction Cell
  POLLUTANT Fluoride NEI CAS 16984-48-8
    Primary Control / Secondary Control : TRAY-TYPE GAS ABSORPTION COLUMN , OVERFIRE AIR ,
  Emission Factor -- 3.000E-1 Lb per Ton Molten Aluminum Produced;
Quality -- A    Emissions Factors Applicability    Duplicate factor exists.

SCC 30300302
  Industrial Processes > Primary Metal Production > By-product Coke Manufacturing > Oven Charging
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.800E-1 Lb per Ton Coal Charged;
Quality -- E    Emissions Factors Applicability

SCC 30300302
  Industrial Processes > Primary Metal Production > By-product Coke Manufacturing > Oven Charging
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : TRAY-TYPE GAS ABSORPTION COLUMN ,
  Emission Factor -- 1.400E-2 Lb per Ton Coal Charged;
Quality -- E    Emissions Factors Applicability

SCC 30300303
  Industrial Processes > Primary Metal Production > By-product Coke Manufacturing > Oven Pushing
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CONSERVATION VENT ,
  Emission Factor -- 7.000E-2 Lb per Ton Coal Charged;
Quality -- D    Emissions Factors Applicability

SCC 30300303
  Industrial Processes > Primary Metal Production > By-product Coke Manufacturing > Oven Pushing
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : TRAY-TYPE GAS ABSORPTION COLUMN ,
  Emission Factor -- 7.200E-2 Lb per Ton Coal Charged;
Quality -- C    Emissions Factors Applicability

SCC 30300303
  Industrial Processes > Primary Metal Production > By-product Coke Manufacturing > Oven Pushing
  POLLUTANT Sulfur oxides (SOx) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.300E0 Lb per Ton Coal Charged;
Quality -- U    Emissions Factors Applicability

SCC 30300308
  Industrial Processes > Primary Metal Production > By-product Coke Manufacturing > Oven/Door Leaks
  POLLUTANT Sulfur oxides (SOx) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.940E-1 Lb per Ton Coal Charged;
Quality -- U    Emissions Factors Applicability

SCC 30300317
  Industrial Processes > Primary Metal Production > By-product Coke Manufacturing > Combustion Stack: Coke Oven Gas (COG)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.500E-1 Lb per Ton Coal Charged;
Quality -- E    Emissions Factors Applicability

SCC 30300318
  Industrial Processes > Primary Metal Production > By-product Coke Manufacturing > Combustion Stack: Blast Furnace Gas (BFG)
  POLLUTANT Sulfur dioxide NEI SO2 CAS 7446-09-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.080E0 Lb per Ton Coal Charged;
Quality -- C    Emissions Factors Applicability

SCC 30300399
  Industrial Processes > Primary Metal Production > By-product Coke Manufacturing > Not Classified **
  POLLUTANT Benzo(a)pyrene NEI 50328 CAS 50-32-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.100E1 mg per Megagram Coal Burned;
Quality -- U    Emissions Factors Applicability

SCC 30300524
  Industrial Processes > Primary Metal Production > Primary Copper Smelting > AFT MHR+RF/FBR+EF
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.120E1 Lb per Ton Concentrated Ore Processed;
Quality -- B    Emissions Factors Applicability

SCC 30300527
  Industrial Processes > Primary Metal Production > Primary Copper Smelting > Dryer with Flash Furnace and Converter
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : SULFURIC ACID PLANT ,
  Emission Factor -- 1.000E1 Lb per Ton Concentrated Ore Processed;
Quality -- B    Emissions Factors Applicability    Duplicate factor exists.

SCC 30300530
  Industrial Processes > Primary Metal Production > Primary Copper Smelting > Fluid Bed Roaster with Electric Furnace and Converter
  POLLUTANT Sulfur dioxide NEI SO2 CAS 7446-09-5
    Primary Control / Secondary Control : SULFURIC ACID PLANT ,
  Emission Factor -- 6.000E2 Lb per Ton Concentrated Ore Processed;
Quality -- B    Emissions Factors Applicability    Duplicate factor exists.

SCC 30300534
  Industrial Processes > Primary Metal Production > Primary Copper Smelting > Flash Furnace After Concentrate Dryer
  POLLUTANT Sulfur oxides (SOx) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.200E2 Lb per Ton Concentrated Ore Processed;
Quality -- U    Emissions Factors Applicability

SCC 30300601
  Industrial Processes > Primary Metal Production > Ferroalloy, Open Furnace > 50% FeSi: Electric Smelting Furnace
  POLLUTANT Chromium NEI 7440473 CAS 7440-47-3
    Primary Control / Secondary Control : TRAY-TYPE GAS ABSORPTION COLUMN ,
  Emission Factor -- 7.000E-3 Lb per Megawatt-Hour Energy Input;
Quality -- U    Emissions Factors Applicability

SCC 30300701
  Industrial Processes > Primary Metal Production > Ferroalloy, Semi-covered Furnace > Ferromanganese: Electric Arc Furnace
  POLLUTANT Selenium NEI 7782492 CAS 7782-49-2
    Primary Control / Secondary Control : CONSERVATION VENT ,
  Emission Factor -- 4.600E-7 Lb per Megawatt-Hour Energy Consumed;
Quality -- U    Emissions Factors Applicability

SCC 30300701
  Industrial Processes > Primary Metal Production > Ferroalloy, Semi-covered Furnace > Ferromanganese: Electric Arc Furnace
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.400E0 Lb per Ton Material Produced;
Quality -- U    Emissions Factors Applicability

SCC 30300702
  Industrial Processes > Primary Metal Production > Ferroalloy, Semi-covered Furnace > Electric Arc Furnace: Other Alloys/Specify
  POLLUTANT Antimony NEI 7440360 CAS 7440-36-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.680E-3 Lb per Megawatt-Hour Energy Consumed;
Quality -- U    Emissions Factors Applicability

SCC 30300702
  Industrial Processes > Primary Metal Production > Ferroalloy, Semi-covered Furnace > Electric Arc Furnace: Other Alloys/Specify
  POLLUTANT Chromium NEI 7440473 CAS 7440-47-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.200E-2 Lb per Megawatt-Hour Energy Consumed;
Quality -- U    Emissions Factors Applicability

SCC 30300805
  Industrial Processes > Primary Metal Production > Iron Production (See 3-03-015 for Integrated Iron & Steel MACT) > Loader: Low-Silt
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.800E-3 Lb per Ton Slag Transferred;
Quality -- U    Emissions Factors Applicability

SCC 30300822
  Industrial Processes > Primary Metal Production > Iron Production (See 3-03-015 for Integrated Iron & Steel MACT) > Raw Material Stockpile: Ore, Pellets, Limestone, Coke, Sinter
  POLLUTANT Copper NEI CAS 7440-50-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.000E-3 Lb per Ton Hot Metal Produced;
Quality -- U    Emissions Factors Applicability

SCC 30300908
  Industrial Processes > Primary Metal Production > Steel Manufacturing (See 3-03-015 for Integrated Iron & Steel MACT) > Electric Arc Furnace: Carbon Steel (Stack)
  POLLUTANT Manganese oxide NEI 1317346 CAS 1317-34-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 9.600E-3 - 2.400E-1 Lb per Ton Material Produced;
Quality -- U    Emissions Factors Applicability    Duplicate factor exists.

SCC 30300908
  Industrial Processes > Primary Metal Production > Steel Manufacturing (See 3-03-015 for Integrated Iron & Steel MACT) > Electric Arc Furnace: Carbon Steel (Stack)
  POLLUTANT Nickel NEI 7440020 CAS 7440-02-0
    Primary Control / Secondary Control : DUCT SORBENT INJECTION ,
  Emission Factor -- 1.300E-5 Lb per Ton Material Produced;
Quality -- U    Emissions Factors Applicability

SCC 30300914
  Industrial Processes > Primary Metal Production > Steel Manufacturing (See 3-03-015 for Integrated Iron & Steel MACT) > Basic Oxygen Furnace: Closed Hood-Stack
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.310E1 Lb per Ton Material Produced;
Quality -- B    Emissions Factors Applicability

SCC 30300916
  Industrial Processes > Primary Metal Production > Steel Manufacturing (See 3-03-015 for Integrated Iron & Steel MACT) > Charging: BOF
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.300E-1 Lb per Ton Material Produced;
Quality -- E    Emissions Factors Applicability

SCC 30301001
  Industrial Processes > Primary Metal Production > Lead Production > Sintering: Single Stream
  POLLUTANT Cadmium NEI 7440439 CAS 7440-43-9
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.399E0 Lb per Ton Concentrated Ore Processed;
Quality -- U    Emissions Factors Applicability

SCC 30301002
  Industrial Processes > Primary Metal Production > Lead Production > Blast Furnace Operation
  POLLUTANT Lead NEI 7439921 CAS 7439-92-1
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- 6.700E-2 Lb per Ton Bullion Processed;
Quality -- E    Emissions Factors Applicability

SCC 30301005
  Industrial Processes > Primary Metal Production > Lead Production > Materials Handling (Includes 11, 12, 13, 04, 14)
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E0 Lb per Ton Lead Product Produced;
Quality -- B    Emissions Factors Applicability

SCC 30302351
  Industrial Processes > Primary Metal Production > Taconite Iron Ore Processing > Induration: Grate/Kiln, Gas-fired, Acid Pellets
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : SECONDARY SEAL ON FLOATING ROOF TANK ,
  Emission Factor -- 1.400E-2 Lb per Ton Pellets Produced;
Quality -- D    Emissions Factors Applicability

SCC 30302383
  Industrial Processes > Primary Metal Production > Taconite Iron Ore Processing > Induration: Straight Grate, Oil-fired, Acid Pellets
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.200E0 Lb per Ton Pellets Produced;
Quality -- E    Emissions Factors Applicability

SCC 30302385
  Industrial Processes > Primary Metal Production > Taconite Iron Ore Processing > Induration: Straight Grate, Coke-fired, Acid Pellets
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : SECONDARY SEAL ON FLOATING ROOF TANK , WATER SPRAYS ,
  Emission Factor -- 3.900E-2 Lb per Ton Pellets Produced;
Quality -- E    Emissions Factors Applicability

SCC 30302385
  Industrial Processes > Primary Metal Production > Taconite Iron Ore Processing > Induration: Straight Grate, Coke-fired, Acid Pellets
  POLLUTANT Sulfur dioxide NEI SO2 CAS 7446-09-5
    Primary Control / Secondary Control : SECONDARY SEAL ON FLOATING ROOF TANK , WATER SPRAYS ,
  Emission Factor -- 9.900E-1 Lb per Ton Pellets Produced;
Quality -- D    Emissions Factors Applicability

SCC 30302387
  Industrial Processes > Primary Metal Production > Taconite Iron Ore Processing > Induration: Straight Grate, Coke & Gas-fired, Acid Pellets
  POLLUTANT Beryllium NEI 7440417 CAS 7440-41-7
    Primary Control / Secondary Control : SECONDARY SEAL ON FLOATING ROOF TANK , WATER SPRAYS ,
  Emission Factor -- 2.900E-7 Lb per Ton Pellets Produced;
Quality -- E    Emissions Factors Applicability

SCC 30303006
  Industrial Processes > Primary Metal Production > Zinc Production > Electrolytic Processor
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.000E0 Lb per Ton Concentrated Ore Processed;
Quality -- B    Emissions Factors Applicability

SCC 30303027
  Industrial Processes > Primary Metal Production > Zinc Production > Retort Building: Fugitive Emissions
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.000E0 - 4.000E0 Lb per Ton Product Produced;
Quality -- E    Emissions Factors Applicability

SCC 30303101
  Industrial Processes > Primary Metal Production > Leadbearing Ore Crushing and Grinding > Lead Ore w/ 5.1% Lead Content
  POLLUTANT Lead NEI 7439921 CAS 7439-92-1
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.000E-1 Lb per Ton Ore Processed;
Quality -- B    Emissions Factors Applicability

SCC 30303104
  Industrial Processes > Primary Metal Production > Leadbearing Ore Crushing and Grinding > Lead-Zinc Ore w/ 2% Lead Content
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E0 Lb per Ton Ore Processed;
Quality -- B    Emissions Factors Applicability

SCC 30390001
  Industrial Processes > Primary Metal Production > Fuel Fired Equipment > Distillate Oil (No. 2): Process Heaters
  POLLUTANT Sulfur oxides (SOx) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per 1000 Gallons Distillate Oil (No. 2) Burned;
Quality -- A    Emissions Factors Applicability

SCC 30400109
  Industrial Processes > Secondary Metal Production > Aluminum > Burning/Drying
  POLLUTANT Arsenic NEI 7440382 CAS 7440-38-2
    Primary Control / Secondary Control : CONSERVATION VENT ,
  Emission Factor -- 2.360E-9 Lb per Pounds Cans Processed;
Quality -- U    Emissions Factors Applicability

SCC 30400109
  Industrial Processes > Secondary Metal Production > Aluminum > Burning/Drying
  POLLUTANT Chromium NEI 7440473 CAS 7440-47-3
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- 2.020E-8 Lb per Pounds Cans Processed;
Quality -- U    Emissions Factors Applicability

SCC 30400109
  Industrial Processes > Secondary Metal Production > Aluminum > Burning/Drying
  POLLUTANT Copper NEI CAS 7440-50-8
    Primary Control / Secondary Control : WATER SPRAYS ,
  Emission Factor -- 3.960E-7 Lb per Pounds Cans Processed;
Quality -- U    Emissions Factors Applicability

SCC 30400109
  Industrial Processes > Secondary Metal Production > Aluminum > Burning/Drying
  POLLUTANT Heptachlorodibenzo-p-dioxins, total NEI 37871004 CAS
    Primary Control / Secondary Control : CONSERVATION VENT ,
  Emission Factor -- 5.860E-11 Lb per Pounds Cans Processed;
Quality -- U    Emissions Factors Applicability

SCC 30400109
  Industrial Processes > Secondary Metal Production > Aluminum > Burning/Drying
  POLLUTANT Hexachlorodibenzo-p-dioxins, total NEI 34465468 CAS 34465-46-8
    Primary Control / Secondary Control : CONSERVATION VENT ,
  Emission Factor -- 7.800E-11 Lb per Pounds Cans Processed;
Quality -- U    Emissions Factors Applicability

SCC 30400109
  Industrial Processes > Secondary Metal Production > Aluminum > Burning/Drying
  POLLUTANT Lead NEI 7439921 CAS 7439-92-1
    Primary Control / Secondary Control : WATER SPRAYS ,
  Emission Factor -- 1.080E-5 Lb per Pounds Cans Processed;
Quality -- U    Emissions Factors Applicability

SCC 30400109
  Industrial Processes > Secondary Metal Production > Aluminum > Burning/Drying
  POLLUTANT Mercury NEI 7439976 CAS 7439-97-6
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- 2.800E-9 Lb per Pounds Cans Processed;
Quality -- U    Emissions Factors Applicability

SCC 30400109
  Industrial Processes > Secondary Metal Production > Aluminum > Burning/Drying
  POLLUTANT Pentachlorodibenzofurans, total NEI 30402154 CAS
    Primary Control / Secondary Control : CONSERVATION VENT ,
  Emission Factor -- 5.840E-10 Lb per Pounds Cans Processed;
Quality -- U    Emissions Factors Applicability

SCC 30400219
  Industrial Processes > Secondary Metal Production > Copper > Charge with Brass and Bronze: Crucible and Pot Furnace
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.240E1 Lb per Ton Charge Fed;
Quality -- E    Emissions Factors Applicability

SCC 30400221
  Industrial Processes > Secondary Metal Production > Copper > Charge with Brass and Bronze: Electric Arc Furnace
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.100E1 Lb per Ton Charge Fed;
Quality -- B    Emissions Factors Applicability

SCC 30400221
  Industrial Processes > Secondary Metal Production > Copper > Charge with Brass and Bronze: Electric Arc Furnace
  POLLUTANT PM, primary NEI PM-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.100E1 Lb per Ton Charge Fed;
Quality -- B    Emissions Factors Applicability

SCC 30400223
  Industrial Processes > Secondary Metal Production > Copper > Charge with Copper: Electric Induction
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.000E0 Lb per Ton Charge Fed;
Quality -- E    Emissions Factors Applicability

SCC 30400224
  Industrial Processes > Secondary Metal Production > Copper > Charge with Brass and Bronze: Electric Induction
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.000E1 Lb per Ton Charge Fed;
Quality -- B    Emissions Factors Applicability

SCC 30400234
  Industrial Processes > Secondary Metal Production > Copper > Cupola Furnace
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.200E0 Lb per Ton Charge Fed;
Quality -- E    Emissions Factors Applicability

SCC 30400301
  Industrial Processes > Secondary Metal Production > Grey Iron Foundries > Cupola
  POLLUTANT 1,2,3,7,8,9-Hexachlorodibenzofuran NEI 72918219 CAS 72918-21-9
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- 3.098E-10 Lb per Ton Cast Pipe Produced;
Quality -- U    Emissions Factors Applicability

SCC 30400301
  Industrial Processes > Secondary Metal Production > Grey Iron Foundries > Cupola
  POLLUTANT Lead NEI 7439921 CAS 7439-92-1
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- 2.672E-3 Lb per Ton Metal Charged;
Quality -- U    Emissions Factors Applicability

SCC 30400305
  Industrial Processes > Secondary Metal Production > Grey Iron Foundries > Annealing Operation
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.000E0 Lb per Ton Material Processed;
Quality -- U    Emissions Factors Applicability

SCC 30400402
  Industrial Processes > Secondary Metal Production > Lead > Reverberatory Furnace
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.938E2 Lb per Ton Metal Charged;
Quality -- U    Emissions Factors Applicability

SCC 30400402
  Industrial Processes > Secondary Metal Production > Lead > Reverberatory Furnace
  POLLUTANT Sulfur oxides (SOx) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.000E1 Lb per Ton Metal Charged;
Quality -- B    Emissions Factors Applicability

SCC 30400870
  Industrial Processes > Secondary Metal Production > Zinc > Electric Induction Melting Furnace
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E-3 Lb per Ton Material Produced;
Quality -- E    Emissions Factors Applicability

SCC 30400873
  Industrial Processes > Secondary Metal Production > Zinc > Casting
  POLLUTANT Cadmium NEI 7440439 CAS 7440-43-9
    Primary Control / Secondary Control : MIST ELIMINATOR - HIGH EFFICIENCY , DUCT SORBENT INJECTION ,
  Emission Factor -- 1.000E-5 Lb per Ton Material Produced;
Quality -- U    Emissions Factors Applicability

SCC 30400873
  Industrial Processes > Secondary Metal Production > Zinc > Casting
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.500E-2 Lb per Ton Material Produced;
Quality -- E    Emissions Factors Applicability

SCC 30500101
  Industrial Processes > Mineral Products > Asphalt Roofing Manufacture > Asphalt Blowing: Saturant (Use 3-05-050-10 for MACT)
  POLLUTANT Fluoranthene NEI 206440 CAS 206-44-0
    Primary Control / Secondary Control : POWDER COATINGS ,
  Emission Factor -- 1.200E0 mg per Megagram Asphalt Produced;
Quality -- U    Emissions Factors Applicability

SCC 30500623
  Industrial Processes > Mineral Products > Cement Manufacturing (Dry Process) > Preheater/Precalciner Kiln
  POLLUTANT Carbon sulfide NEI 75150 CAS 75-15-0
    Primary Control / Secondary Control : SULFURIC ACID PLANT ,
  Emission Factor -- 1.100E-4 Lb per Ton Clinker Produced;
Quality -- D    Emissions Factors Applicability

SCC 10100903
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CENTRIFUGAL COLLECTOR (CYCLONE) - MEDIUM EFFICIENCY ,
  Emission Factor -- 2.700E-1 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability
    Revoked on 11/20/2007

SCC 10101002
  External Combustion Boilers > Electric Generation > Liquified Petroleum Gas (LPG) > Propane
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.420E-1 Lb per 1000 Gallons Propane Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/2004

SCC 10100304
  External Combustion Boilers > Electric Generation > Lignite > Traveling Grate (Overfeed) Stoker
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.000E-2 Lb per MMBtu Heat Input;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/2004

SCC 10100901
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Benzofluoranthenes NEI 56832736 CAS 56832-73-6
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.080E-6 Lb per Ton Bark Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10100901
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Copper NEI CAS 7440-50-8
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.730E-4 Lb per Ton Bark Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10100901
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Manganese NEI 7439965 CAS 7439-96-5
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.260E-2 Lb per Ton Bark Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10100901
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Methane NEI CAS 74-82-8
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.120E-2 Lb per Ton Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10100901
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Nickel NEI 7440020 CAS 7440-02-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 6.900E-5 Lb per Ton Bark Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10100901
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CATALYTIC AFTERBURNER ,
  Emission Factor -- 9.000E0 Lb per Ton Wood Waste Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10100902
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood/Bark Fired Boiler
  POLLUTANT Chrysene NEI 218019 CAS 218-01-9
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.520E-7 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10100902
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood/Bark Fired Boiler
  POLLUTANT Cobalt NEI 7440484 CAS 7440-48-4
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.300E-4 Lb per Ton Wood/Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10100902
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood/Bark Fired Boiler
  POLLUTANT Lead NEI 7439921 CAS 7439-92-1
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.450E-4 Lb per Ton Wood/Bark Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10100902
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood/Bark Fired Boiler
  POLLUTANT Phenol NEI 108952 CAS 108-95-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.470E-4 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10100902
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood/Bark Fired Boiler
  POLLUTANT Sodium NEI CAS 7440-23-5
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.800E-2 Lb per Ton Wood/Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10100902
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood/Bark Fired Boiler
  POLLUTANT Yttrium NEI CAS 7440-65-5
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 5.600E-5 Lb per Ton Wood/Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10100903
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Barium NEI CAS 7440-39-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.400E-3 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10100903
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Benzo(k)fluoranthene NEI 207089 CAS 207-08-9
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 7.650E-7 Lb per Ton Wood Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10100903
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Bromine NEI CAS 7726-95-6
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.900E-4 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10100903
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Chlorine NEI 7782505 CAS 7782-50-5
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 7.800E-3 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10100903
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Neodymium NEI CAS 7440-00-8
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.600E-5 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10100903
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Phenanthrene NEI 85018 CAS 85-01-8
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 5.200E-5 Lb per Ton Wood Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10100903
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.800E0 Lb per Ton Wood Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Barium NEI CAS 7440-39-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.400E-3 Lb per Ton Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Benzo(g,h,i)perylene NEI 191242 CAS 191-24-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.410E-6 Lb per Ton Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
    Primary Control / Secondary Control : SECONDARY SEAL ON FLOATING ROOF TANK ,
  Emission Factor -- 1.620E0 Lb per Ton Wood Waste Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Praseodymium NEI CAS 7440-10-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.000E-5 Lb per Ton Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Rubidium NEI CAS 7440-17-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.200E-3 Lb per Ton Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Vanadium NEI CAS 7440-62-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.200E-4 Lb per Ton Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10200902
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Iodine NEI CAS 7553-56-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.800E-5 Lb per Ton Wood/Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10200902
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT 4-Nitrophenol NEI 100027 CAS 100-02-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.970E-6 Lb per Ton Wood/Bark Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10200902
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.360E-1 Lb per Ton Wood/Bark Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10200902
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Zinc NEI CAS 7440-66-6
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.510E-3 Lb per Ton Wood/Bark Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Acetaldehyde NEI 75070 CAS 75-07-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.920E-3 Lb per Ton Wood Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Polychlorinated dibenzofurans, total NEI 136677106 CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.900E-8 Lb per Ton Wood Burned;
Quality -- C    Emissions Factors Applicability    Duplicate factor exists.
    Revoked on 09/01/2003

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT 2,3,7,8-Tetrachlorodibenzo-p-dioxin NEI 1746016 CAS 1746-01-6
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.600E-11 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Polychlorinated dibenzofurans, total NEI 136677106 CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.900E-8 Lb per Ton Bark Burned;
Quality -- C    Emissions Factors Applicability    Duplicate factor exists.
    Revoked on 09/01/2003

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Benzo(a)anthracene NEI 56553 CAS 56-55-3
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.270E-6 Lb per Ton Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT 2-Chlorophenol NEI CAS 95-57-8
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 5.130E-7 Lb per Ton Bark Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Fluoranthene NEI 206440 CAS 206-44-0
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.830E-5 Lb per Ton Bark Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Molybdenum NEI CAS 7439-98-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.900E-4 Lb per Ton Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Tin NEI CAS 7440-31-5
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.100E-5 Lb per Ton Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Vanadium NEI CAS 7440-62-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.200E-4 Lb per Ton Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Cadmium NEI 7440439 CAS 7440-43-9
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.120E-5 Lb per Ton Wood/Bark Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Cobalt NEI 7440484 CAS 7440-48-4
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.300E-4 Lb per Ton Wood/Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Dysprosium NEI CAS 7429-91-6
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.300E-5 Lb per Ton Wood/Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT 4-Nitrophenol NEI 100027 CAS 100-02-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 2.970E-6 Lb per Ton Wood/Bark Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Phenol NEI 108952 CAS 108-95-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.470E-4 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CATALYTIC AFTERBURNER ,
  Emission Factor -- 1.700E0 Lb per Ton Wood/Bark Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : SECONDARY SEAL ON FLOATING ROOF TANK ,
  Emission Factor -- 4.700E-1 Lb per Ton Wood/Bark Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Zirconium NEI CAS 7440-67-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 3.500E-4 Lb per Ton Wood/Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 10300903
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Molybdenum NEI CAS 7439-98-7
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.900E-4 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2003

SCC 30500251
  Industrial Processes > Mineral Products > Asphalt Concrete > Batch Mix Plant: Rotary Dryer, Natural Gas-Fired (also see -45)
  POLLUTANT Ethylbenzene NEI 100414 CAS 100-41-4
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.300E-3 Lb per Ton Hot Mix Asphalt Produced;
Quality -- D    Emissions Factors Applicability
    Revoked on 12/01/2000

SCC 10100306
  External Combustion Boilers > Electric Generation > Lignite > Spreader Stoker
  POLLUTANT PM, condensable organics NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.000E-3 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/2000

SCC 10100903
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT PM, primary NEI PM-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.800E0 Lb per Ton Wood Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 09/01/2000

SCC 10200221
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Wet Bottom (Subbituminous Coal)
  POLLUTANT PM, condensable organics NEI CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- Formula Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/2000

SCC 10200222
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT PM, condensable organics NEI CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- Formula Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/2000

SCC 10200401
  External Combustion Boilers > Industrial > Residual Oil > Grade 6 Oil
  POLLUTANT PM, condensable inorganics NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.300E0 Lb per 1000 Gallons Residual Oil Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/2000

SCC 10200501
  External Combustion Boilers > Industrial > Distillate Oil > Grades 1 and 2 Oil
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : WET SCRUBBER - LOW EFFICIENCY , ULTRA LOW NOX BURNERS (ULNB) ,
  Emission Factor -- 2.000E0 Lb per 1000 Gallons Distillate Oil (No. 1 & 2) Burned;
Quality -- A    Emissions Factors Applicability
    Revoked on 09/01/2000

SCC 10300221
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Wet Bottom (Subbituminous Coal)
  POLLUTANT PM, condensable organics NEI CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- Formula Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/2000

SCC 10300309
  External Combustion Boilers > Commercial/Institutional > Lignite > Spreader Stoker
  POLLUTANT PM, condensable organics NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.000E-3 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/2000

SCC 20100902
  Internal Combustion Engines > Electric Generation > Kerosene/Naphtha (Jet Fuel) > Reciprocating
  POLLUTANT Total organic compounds (TOC) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.930E1 Lb per 1000 Gallons Jet Fuel Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2000

SCC 20200902
  Internal Combustion Engines > Industrial > Kerosene/Naphtha (Jet Fuel) > Reciprocating
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.040E2 Lb per 1000 Gallons Jet Fuel Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2000

SCC 30200709
  Industrial Processes > Food and Agriculture > Grain Millings > Barley Malting: Gas-fired Malt Kiln
  POLLUTANT PM, condensable inorganics NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.500E-2 Lb per Ton Grain Processed;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/2000

SCC 30201304
  Industrial Processes > Food and Agriculture > Meat Smokehouses > Continuous Smokehouse: Smoke Zone
  POLLUTANT PM, condensable organics NEI CAS
    Primary Control / Secondary Control : SECONDARY SEAL ON FLOATING ROOF TANK , SCREENED DRUMS OR CAGES ,
  Emission Factor -- 6.000E0 Lb per Ton Sawdust Used;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/2000

SCC 30302350
  Industrial Processes > Primary Metal Production > Taconite Iron Ore Processing > Grate/Kiln Furnace Discharge
  POLLUTANT PM, condensable NEI PM-CON CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 9.000E-5 Lb per Ton Pellets Produced;
Quality -- E    Emissions Factors Applicability    Duplicate factor exists.
    Revoked on 09/01/2000

SCC 20200253
  Internal Combustion Engines > Industrial > Natural Gas > 4-cycle Rich Burn
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : PROCESS ENCLOSED ,
  Emission Factor -- 7.350E-1 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 07/01/2000

SCC 20100101
  Internal Combustion Engines > Electric Generation > Distillate Oil (Diesel) > Turbine
  POLLUTANT Phosphorus (yellow or white) NEI 7723140 CAS 7723-14-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.000E-4 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability
    Revoked on 04/01/2000

SCC 20100101
  Internal Combustion Engines > Electric Generation > Distillate Oil (Diesel) > Turbine
  POLLUTANT Sodium NEI CAS 7440-23-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.400E-3 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability
    Revoked on 04/01/2000

SCC 20100901
  Internal Combustion Engines > Electric Generation > Kerosene/Naphtha (Jet Fuel) > Turbine
  POLLUTANT PM, primary NEI PM-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.540E0 Lb per 1000 Gallons Jet Fuel Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 04/01/2000

SCC 20200101
  Internal Combustion Engines > Industrial > Distillate Oil (Diesel) > Turbine
  POLLUTANT PM, primary NEI PM-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.540E0 Lb per 1000 Gallons Distillate Oil (Diesel) Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 04/01/2000

SCC 20200201
  Internal Combustion Engines > Industrial > Natural Gas > Turbine
  POLLUTANT Formaldehyde NEI 50000 CAS 50-00-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.254E-4 Lb per MMBtu Heat Input;
Quality -- U    Emissions Factors Applicability
    Revoked on 04/01/2000

SCC 20200201
  Internal Combustion Engines > Industrial > Natural Gas > Turbine
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.400E1 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 04/01/2000

SCC 20200203
  Internal Combustion Engines > Industrial > Natural Gas > Turbine: Cogeneration
  POLLUTANT Carbon monoxide NEI CO CAS 630-08-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.150E2 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- A    Emissions Factors Applicability
    Revoked on 04/01/2000

SCC 20200203
  Internal Combustion Engines > Industrial > Natural Gas > Turbine: Cogeneration
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.260E1 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- U    Emissions Factors Applicability
    Revoked on 04/01/2000

SCC 20300202
  Internal Combustion Engines > Commercial/Institutional > Natural Gas > Turbine
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.620E2 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 04/01/2000

SCC 20200402
  Internal Combustion Engines > Industrial > Large Bore Engine > Dual Fuel (Oil/Gas)
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.170E1 Lb per 1000 Horsepower-Hours Work Output;
Quality -- D    Emissions Factors Applicability
    Revoked on 01/01/2000

SCC 30102707
  Industrial Processes > Chemical Manufacturing > Ammonium Nitrate Production > Rotary Drum Granulator
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.800E0 Lb per Ton Ammonium Nitrate Produced;
Quality -- A    Emissions Factors Applicability
    Revoked on 01/01/2000

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT PM, primary NEI PM-PRI CAS
    Primary Control / Secondary Control : WATER SPRAYS ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT PM, primary NEI PM-PRI CAS
    Primary Control / Secondary Control : TRAY-TYPE GAS ABSORPTION COLUMN ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10100204
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Spreader Stoker (Bituminous Coal)
  POLLUTANT PM, primary NEI PM-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.600E1 Lb per Ton Bituminous Coal Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10100204
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Spreader Stoker (Bituminous Coal)
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : SULFURIC ACID PLANT ,
  Emission Factor -- 3.000E-1 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10100205
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Traveling Grate (Overfeed) Stoker (Bituminous Coal)
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E0 Lb per Ton Bituminous Coal Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10100306
  External Combustion Boilers > Electric Generation > Lignite > Spreader Stoker
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : WATER SPRAYS ,
  Emission Factor -- Formula Lb per Ton Lignite Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10100306
  External Combustion Boilers > Electric Generation > Lignite > Spreader Stoker
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Lignite Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10100404
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 6 Oil: Tangential Firing
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : SULFURIC ACID PLANT ,
  Emission Factor -- Formula Lb per 1000 Gallons Residual Oil (No. 6) Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10200204
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Spreader Stoker
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : SULFURIC ACID PLANT ,
  Emission Factor -- 3.000E-1 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10200206
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Underfeed Stoker
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.800E0 Lb per Ton Bituminous Coal Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10200403
  External Combustion Boilers > Industrial > Residual Oil > < 10 Million Btu/hr **
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per 1000 Gallons Residual Oil Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10200212
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential)
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : WATER SPRAYS ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10200501
  External Combustion Boilers > Industrial > Distillate Oil > Grades 1 and 2 Oil
  POLLUTANT PM, primary NEI PM-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.000E0 Lb per 1000 Gallons Distillate Oil (No. 1 & 2) Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10200502
  External Combustion Boilers > Industrial > Distillate Oil > 10-100 Million Btu/hr **
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.500E-1 Lb per 1000 Gallons Distillate Oil Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10200902
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT PM, primary NEI PM-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.200E0 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10200904
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT PM, primary NEI PM-PRI CAS
    Primary Control / Secondary Control : FABRIC FILTER - LOW TEMPERATURE , I.E. T<180F ,
  Emission Factor -- 1.400E1 Lb per Ton Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10200905
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT PM, primary NEI PM-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.200E0 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10200905
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : SECONDARY SEAL ON FLOATING ROOF TANK ,
  Emission Factor -- 4.320E-1 Lb per Ton Wood/Bark Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10300203
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Cyclone Furnace (Bituminous Coal)
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10300205
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Wet Bottom (Bituminous Coal)
  POLLUTANT PM, primary NEI PM-PRI CAS
    Primary Control / Secondary Control : WATER SPRAYS ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10300206
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10300216
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential) (Bituminous Coal)
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10300402
  External Combustion Boilers > Commercial/Institutional > Residual Oil > 10-100 Million Btu/hr **
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per 1000 Gallons Residual Oil Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10300404
  External Combustion Boilers > Commercial/Institutional > Residual Oil > Grade 5 Oil
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per 1000 Gallons Residual Oil (No. 5) Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10300501
  External Combustion Boilers > Commercial/Institutional > Distillate Oil > Grades 1 and 2 Oil
  POLLUTANT PM2.5, primary NEI PM25-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.300E-1 Lb per 1000 Gallons Distillate Oil (No. 1 & 2) Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 12/01/1999

SCC 10200101
  External Combustion Boilers > Industrial > Anthracite Coal > Pulverized Coal
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : WATER SPRAYS ,
  Emission Factor -- 1.100E0 Lb per Ton Anthracite Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 11/30/1999

SCC 10300101
  External Combustion Boilers > Commercial/Institutional > Anthracite Coal > Pulverized Coal
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : WATER SPRAYS ,
  Emission Factor -- 1.100E0 Lb per Ton Anthracite Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 11/30/1999

SCC 30200784
  Industrial Processes > Food and Agriculture > Grain Millings > Soybean: Drying
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Soybeans Processed;
Quality -- U    Emissions Factors Applicability
    Revoked on 06/14/1999

SCC 10100901
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Phenol NEI 108952 CAS 108-95-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.470E-5 Lb per Ton Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1999

SCC 10100902
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood/Bark Fired Boiler
  POLLUTANT Chrysene NEI 218019 CAS 218-01-9
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.200E-7 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1999

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Phenol NEI 108952 CAS 108-95-2
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.470E-5 Lb per Ton Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1999

SCC 10200902
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Chrysene NEI 218019 CAS 218-01-9
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 4.200E-7 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1999

SCC 10200907
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood Cogeneration
  POLLUTANT Polychlorinated dibenzofurans, total NEI 136677106 CAS
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 5.300E-8 Lb per Ton Wood Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1999

SCC 30202002
  Industrial Processes > Food and Agriculture > Beef Cattle Feedlots > Feedlots: General
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.700E-2 Lb per Each Head of Cattle Throughput;
Quality -- U    Emissions Factors Applicability
    Revoked on 12/08/1998

SCC 10200205
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Overfeed Stoker
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E0 Lb per Ton Bituminous Coal Burned;
Quality -- B    Emissions Factors Applicability    Duplicate factor exists.
    Revoked on 09/15/1998

SCC 30104012
  Industrial Processes > Chemical Manufacturing > Urea Production > Rotary Drum Cooler
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.450E0 Lb per Ton Urea Produced;
Quality -- A    Emissions Factors Applicability    Duplicate factor exists.
    Revoked on 09/15/1998

SCC 10200221
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Wet Bottom (Subbituminous Coal)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Subbituminous Coal Burned;
Quality -- D    Emissions Factors Applicability    Duplicate factor exists.
    Revoked on 09/11/1998

SCC 10300226
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom Tangential (Subbituminous Coal)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Subbituminous Coal Burned;
Quality -- A    Emissions Factors Applicability    Duplicate factor exists.
    Revoked on 09/11/1998

SCC 30101901
  Industrial Processes > Chemical Manufacturing > Phthalic Anhydride > o-Xylene Oxidation: Main Process Stream
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.380E2 Lb per Ton Phthalic Anhydride Produced;
Quality -- B    Emissions Factors Applicability    Duplicate factor exists.
    Revoked on 09/11/1998

SCC 30101906
  Industrial Processes > Chemical Manufacturing > Phthalic Anhydride > Naphthalene Oxidation: Pre-Treatment
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E0 Lb per Ton Phthalic Anhydride Produced;
Quality -- B    Emissions Factors Applicability    Duplicate factor exists.
    Revoked on 09/11/1998

SCC 30400409
  Industrial Processes > Secondary Metal Production > Lead > Casting
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 8.700E-1 Lb per Ton Lead Cast;
Quality -- E    Emissions Factors Applicability    Duplicate factor exists.
    Revoked on 09/11/1998

SCC 30300603
  Industrial Processes > Primary Metal Production > Ferroalloy, Open Furnace > 90% FeSi: Electric Smelting Furnace
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.640E2 Lb per Ton Material Produced;
Quality -- C    Emissions Factors Applicability    Duplicate factor exists.
    Revoked on 09/11/1998

SCC 30303008
  Industrial Processes > Primary Metal Production > Zinc Production > Fluid Bed Roaster
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.170E3 Lb per Ton Concentrated Ore Processed;
Quality -- U    Emissions Factors Applicability    Duplicate factor exists.
    Revoked on 09/11/1998

SCC 30400235
  Industrial Processes > Secondary Metal Production > Copper > Reverberatory Furnace
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.100E0 Lb per Ton Charge Fed;
Quality -- U    Emissions Factors Applicability    Duplicate factor exists.
    Revoked on 09/11/1998

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10100202
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT Tetrachlorodibenzo-p-dioxins, total NEI CAS
    Primary Control / Secondary Control : DUST SUPPRESSION BY WATER SPRAYS ,
  Emission Factor -- 3.930E-10 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10100204
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Spreader Stoker (Bituminous Coal)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : SULFURIC ACID PLANT ,
  Emission Factor -- 4.400E-1 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10100212
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential) (Bituminous Coal)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10100212
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential) (Bituminous Coal)
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E-2 Lb per Ton Bituminous Coal Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10100218
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Atmospheric Fluidized Bed Combustion: Circulating Bed (Bitum. Coal)
  POLLUTANT Nitrous oxide NEI CAS 10024-97-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.500E0 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10100222
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Lead NEI 7439921 CAS 7439-92-1
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.330E-2 Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10100222
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Tetrachlorodibenzofurans, total NEI CAS
    Primary Control / Secondary Control : DUST SUPPRESSION BY WATER SPRAYS ,
  Emission Factor -- 2.490E-9 Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10100223
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Cyclone Furnace (Subbituminous Coal)
  POLLUTANT Lead NEI 7439921 CAS 7439-92-1
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.330E-2 Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10100223
  External Combustion Boilers > Electric Generation > Bituminous/Subbituminous Coal > Cyclone Furnace (Subbituminous Coal)
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.380E1 Lb per Ton Subbituminous Coal Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10100301
  External Combustion Boilers > Electric Generation > Lignite > Pulverized Coal: Dry Bottom, Wall Fired
  POLLUTANT Chromium NEI 7440473 CAS 7440-47-3
    Primary Control / Secondary Control : WATER SPRAYS ,
  Emission Factor -- 6.700E-5 - 7.400E-5 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10100302
  External Combustion Boilers > Electric Generation > Lignite > Pulverized Coal: Dry Bottom, Tangential Fired
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : MODIFIED BURNER OR FURNACE DESIGN ,
  Emission Factor -- 6.600E0 Lb per Ton Lignite Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10100306
  External Combustion Boilers > Electric Generation > Lignite > Spreader Stoker
  POLLUTANT Mercury NEI 7439976 CAS 7439-97-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.100E-5 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10100404
  External Combustion Boilers > Electric Generation > Residual Oil > Grade 6 Oil: Tangential Firing
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.600E-1 Lb per 1000 Gallons Residual Oil (No. 6) Burned;
Quality -- A    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10200225
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Traveling Grate (Overfeed) Stoker (Subbituminous Coal)
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E-2 Lb per Ton Subbituminous Coal Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10200205
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Overfeed Stoker
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : WATER SPRAYS ,
  Emission Factor -- 5.000E-2 Lb per Ton Bituminous Coal Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10200212
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Tangential)
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E-2 Lb per Ton Bituminous Coal Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10200226
  External Combustion Boilers > Industrial > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom Tangential (Subbituminous Coal)
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E-2 Lb per Ton Subbituminous Coal Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10200304
  External Combustion Boilers > Industrial > Lignite > Traveling Grate (Overfeed) Stoker
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per Ton Lignite Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10200401
  External Combustion Boilers > Industrial > Residual Oil > Grade 6 Oil
  POLLUTANT Beryllium NEI 7440417 CAS 7440-41-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.200E-6 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10300205
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Wet Bottom (Bituminous Coal)
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : SULFURIC ACID PLANT ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10300206
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : ROTOCLONE ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10300206
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Bituminous Coal)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : SULFURIC ACID PLANT ,
  Emission Factor -- Formula Lb per Ton Bituminous Coal Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10300218
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Atmospheric Fluidized Bed Combustion: Circulating Bed (Bitum. Coal)
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.800E0 Lb per Ton Bituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10300222
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Lead NEI 7439921 CAS 7439-92-1
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.330E-2 Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10300222
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Octachlorodibenzofurans, total NEI 39001020 CAS 39001-02-0
    Primary Control / Secondary Control : DUST SUPPRESSION BY WATER SPRAYS ,
  Emission Factor -- 1.370E-7 Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10300222
  External Combustion Boilers > Commercial/Institutional > Bituminous/Subbituminous Coal > Pulverized Coal: Dry Bottom (Subbituminous Coal)
  POLLUTANT Polychlorinated dibenzo-p-dioxins and furans, total NEI 136677093 CAS
    Primary Control / Secondary Control : DUST SUPPRESSION BY WATER SPRAYS ,
  Emission Factor -- 2.440E-7 Lb per Ton Subbituminous Coal Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10300401
  External Combustion Boilers > Commercial/Institutional > Residual Oil > Grade 6 Oil
  POLLUTANT Antimony NEI 7440360 CAS 7440-36-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.400E-5 - 4.600E-5 Lb per MMBtu Heat Input;
Quality -- E    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10300401
  External Combustion Boilers > Commercial/Institutional > Residual Oil > Grade 6 Oil
  POLLUTANT Sulfur oxides (SOx) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- Formula Lb per 1000 Gallons Residual Oil (No. 6) Burned;
Quality -- A    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10300402
  External Combustion Boilers > Commercial/Institutional > Residual Oil > 10-100 Million Btu/hr **
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.130E0 Lb per 1000 Gallons Residual Oil Burned;
Quality -- A    Emissions Factors Applicability
    Revoked on 09/01/1998

SCC 10100903
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Trichlorotrifluoroethane NEI CAS 76-13-1
    Primary Control / Secondary Control : DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER ,
  Emission Factor -- 1.960E-1 Lb per Ton Wood Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 08/01/1998

SCC 30200506
  Industrial Processes > Food and Agriculture > Feed and Grain Terminal Elevators > Loading (Shipping)
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.000E-1 Lb per Ton Grain Processed;
Quality -- B    Emissions Factors Applicability
    Revoked on 05/01/1998

SCC 30200711
  Industrial Processes > Food and Agriculture > Grain Millings > Durum Milling: Grain Receiving
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.000E0 Lb per Ton Grain Received;
Quality -- D    Emissions Factors Applicability
    Revoked on 05/01/1998

SCC 30200712
  Industrial Processes > Food and Agriculture > Grain Millings > Durum Milling: Precleaning/Handling
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E0 Lb per Ton Grain Received;
Quality -- D    Emissions Factors Applicability
    Revoked on 05/01/1998

SCC 10200601
  External Combustion Boilers > Industrial > Natural Gas > > 100 Million Btu/hr
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.000E0 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 03/01/1998

SCC 10200602
  External Combustion Boilers > Industrial > Natural Gas > 10-100 Million Btu/hr
  POLLUTANT PM10, primary NEI PM10-PRI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.370E1 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 03/01/1998

SCC 10200604
  External Combustion Boilers > Industrial > Natural Gas > Cogeneration
  POLLUTANT Sulfur oxides (SOx) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.000E-1 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- U    Emissions Factors Applicability
    Revoked on 03/01/1998

SCC 10200604
  External Combustion Boilers > Industrial > Natural Gas > Cogeneration
  POLLUTANT Volatile organic compounds (VOC) NEI VOC CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.400E0 Lb per Million Cubic Feet Natural Gas Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 03/01/1998

SCC 10100901
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Vanadium NEI CAS 7440-62-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.200E-4 Lb per Ton Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10100901
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Benzaldehyde NEI CAS 100-52-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.200E-5 Lb per Ton Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10100901
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Benzo(b+k)fluoranthene NEI 102 CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.900E-5 Lb per Ton Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10100901
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Mercury NEI 7439976 CAS 7439-97-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.500E-6 Lb per Ton Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10100902
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood/Bark Fired Boiler
  POLLUTANT Benzene NEI 71432 CAS 71-43-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.600E-3 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10100902
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood/Bark Fired Boiler
  POLLUTANT Hexavalent Chromium NEI 18540299 CAS 18540-29-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.600E-5 Lb per Ton Wood/Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10100902
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood/Bark Fired Boiler
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.480E0 Lb per Ton Wood/Bark Burned;
Quality -- E    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10100902
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood/Bark Fired Boiler
  POLLUTANT Thorium NEI CAS 7440-29-1
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.700E-5 Lb per Ton Wood/Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10100902
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood/Bark Fired Boiler
  POLLUTANT Vanadium NEI CAS 7440-62-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.200E-4 Lb per Ton Wood/Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10100903
  External Combustion Boilers > Electric Generation > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Formaldehyde NEI 50000 CAS 50-00-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.600E-3 Lb per Ton Wood Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Barium NEI CAS 7440-39-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.400E-3 Lb per Ton Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Formaldehyde NEI 50000 CAS 50-00-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.600E-3 Lb per Ton Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200901
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Zinc NEI CAS 7440-66-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.400E-3 Lb per Ton Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200902
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Formaldehyde NEI 50000 CAS 50-00-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.600E-3 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200902
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Germanium NEI CAS 7440-56-4
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.500E-6 Lb per Ton Wood/Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200902
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Selenium NEI 7782492 CAS 7782-49-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.800E-5 Lb per Ton Wood/Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200902
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT 2,3,7,8-Tetrachlorodibenzo-p-dioxin NEI 1746016 CAS 1746-01-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.600E-11 Lb per Ton Wood/Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200902
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Tin NEI CAS 7440-31-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.100E-5 Lb per Ton Wood/Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Indeno(1,2,3-cd)pyrene NEI 193395 CAS 193-39-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.400E-7 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.500E0 Lb per Ton Wood Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CATALYTIC AFTERBURNER ,
  Emission Factor -- 4.200E0 Lb per Ton Wood Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Solicyaldehyde NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.300E-5 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Total organic compounds (TOC) NEI CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.200E-1 Lb per Ton Wood Burned;
Quality -- U    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200903
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Zinc NEI CAS 7440-66-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.400E-3 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200904
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Acenaphthene NEI 83329 CAS 83-32-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.400E-6 Lb per Ton Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200904
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Copper NEI CAS 7440-50-8
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.900E-4 Lb per Ton Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200904
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Formaldehyde NEI 50000 CAS 50-00-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.600E-3 Lb per Ton Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200904
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.500E0 Lb per Ton Bark Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200904
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CATALYTIC AFTERBURNER ,
  Emission Factor -- 9.000E0 Lb per Ton Bark Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200904
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Polychlorinated dibenzofurans, total NEI 136677106 CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.300E-8 Lb per Ton Bark Burned;
Quality -- C    Emissions Factors Applicability    Duplicate factor exists.
    Revoked on 02/01/1998

SCC 10200904
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Sodium NEI CAS 7440-23-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.800E-2 Lb per Ton Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200904
  External Combustion Boilers > Industrial > Wood/Bark Waste > Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Thorium NEI CAS 7440-29-1
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.700E-5 Lb per Ton Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200905
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Benzene NEI 71432 CAS 71-43-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.600E-3 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200905
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood/Bark-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Benzo(b+k)fluoranthene NEI 102 CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 2.900E-5 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200906
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Chlorine NEI 7782505 CAS 7782-50-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.800E-3 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200906
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Indeno(1,2,3-cd)pyrene NEI 193395 CAS 193-39-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.400E-7 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200906
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Iron NEI CAS 15438-31-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.400E-2 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200906
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT PM10, filterable NEI PM10-FIL CAS
    Primary Control / Secondary Control : CATALYTIC AFTERBURNER ,
  Emission Factor -- 2.600E0 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200906
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Polychlorinated dibenzo-p-dioxins, total NEI 136677093 CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.300E-6 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability    Duplicate factor exists.
    Revoked on 02/01/1998

SCC 10200906
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Praseodymium NEI CAS 7440-10-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.000E-5 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200906
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood-fired Boiler (< 50,000 Lb Steam) **
  POLLUTANT Sodium NEI CAS 7440-23-5
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.800E-2 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200907
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood Cogeneration
  POLLUTANT Fluorene NEI 86737 CAS 86-73-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 9.600E-6 Lb per Ton Wood Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10200907
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood Cogeneration
  POLLUTANT Polychlorinated dibenzo-p-dioxins, total NEI 136677093 CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.200E-8 Lb per Ton Wood Burned;
Quality -- C    Emissions Factors Applicability    Duplicate factor exists.
    Revoked on 02/01/1998

SCC 10200907
  External Combustion Boilers > Industrial > Wood/Bark Waste > Wood Cogeneration
  POLLUTANT Zinc NEI CAS 7440-66-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.400E-3 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Acenaphthene NEI 83329 CAS 83-32-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.400E-6 Lb per Ton Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Benzene NEI 71432 CAS 71-43-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.600E-3 Lb per Ton Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Chromium NEI 7440473 CAS 7440-47-3
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.300E-4 Lb per Ton Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Lithium NEI CAS 7439-93-2
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 7.000E-5 Lb per Ton Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT Pyrene NEI 129000 CAS 129-00-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.670E-5 Lb per Ton Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10300901
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Bark-fired Boiler
  POLLUTANT 2,3,7,8-Tetrachlorodibenzo-p-dioxin NEI 1746016 CAS 1746-01-6
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 3.600E-11 Lb per Ton Bark Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Chrysene NEI 218019 CAS 218-01-9
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.300E-5 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Formaldehyde NEI 50000 CAS 50-00-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 6.600E-3 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT Lead NEI 7439921 CAS 7439-92-1
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.450E-4 Lb per Ton Wood/Bark Burned;
Quality -- B    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10300902
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood/Bark-fired Boiler
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : FABRIC FILTER - LOW TEMPERATURE , I.E. T<180F ,
  Emission Factor -- 6.000E0 Lb per Ton Wood/Bark Burned;
Quality -- C    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10300903
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Iron NEI CAS 15438-31-0
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 4.400E-2 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 10300903
  External Combustion Boilers > Commercial/Institutional > Wood/Bark Waste > Wood-fired Boiler - Wet Wood (>=20% moisture)
  POLLUTANT Tungsten NEI CAS 7440-33-7
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 1.100E-5 Lb per Ton Wood Burned;
Quality -- D    Emissions Factors Applicability
    Revoked on 02/01/1998

SCC 30300108
  Industrial Processes > Primary Metal Production > Aluminum Ore (Electro-reduction) > Prebake: Fugitive Emissions
  POLLUTANT PM, filterable NEI PM-FIL CAS
    Primary Control / Secondary Control : CHEMICAL REDUCTION ,
  Emission Factor -- 5.000E0 Lb per Ton Molten Aluminum Produced;
Quality -- A    Emissions Factors Applicability
    Revoked on 02/01/1998


Choose a format
  CSV (for importing into spreadsheet or database applications)
  XML (for importing into XML parsing applications)
  ASCII (for importing into other applications)
  HTML (for printing)