Emission Factor Details

SCC 10300216
  Level 1 External Combustion Boilers
  Level 2 Commercial/Institutional
  Level 3 Bituminous/Subbituminous Coal
  Level 4 Pulverized Coal: Dry Bottom (Tangential) (Bituminous Coal)
POLLUTANT PM10, filterable NEI PM10-FIL CAS
  Primary Control       CHEMICAL REDUCTION

Emission Factor Formula Lb per Ton Bituminous Coal Burned
Quality E    Emissions Factors Applicability

References EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards. Research Triangle Park, North Carolina.
AP 42 Section Chapter 1   Section 1.1
Formula 2.3E0*A
Notes Multiply the emission factor provided by the weight percent ash content of the coal to obtain lb/ton EF. No data found; assumes emission factor for pulverized coal-fired dry bottom boilers. A=% Ash content.