SCC | 10300209 | ||
Level 1 | External Combustion Boilers | ||
Level 2 | Commercial/Institutional | ||
Level 3 | Bituminous/Subbituminous Coal | ||
Level 4 | Spreader Stoker (Bituminous Coal) | ||
POLLUTANT | Carbon monoxide | NEI CO | CAS 630-08-0 |
Primary Control
CHEMICAL REDUCTION |
|||
Emission Factor | 5.000E0 Lb per Ton Bituminous Coal Burned | ||
Quality | A Emissions Factors Applicability | ||
References | EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards. Research Triangle Park, North Carolina. | ||
AP 42 Section | Chapter 1 Section 1.1 | ||
Formula | |||
Notes | Values of 1 or 2 orders of magnitude higher can occur when combustion is not complete. Emission factors for CO2 emissions from coal combustion should be calculated using CO2/ton coal = 73.3C, where C is the wt. percent carbon content of the coal. |