Emission Factor Details

SCC 10300208
  Level 1 External Combustion Boilers
  Level 2 Commercial/Institutional
  Level 3 Bituminous/Subbituminous Coal
  Level 4 Underfeed Stoker (Bituminous Coal)
POLLUTANT Nitrogen oxides (NOx) NEI NOX CAS
  Primary Control       CHEMICAL REDUCTION

Emission Factor 9.500E0 Lb per Ton Bituminous Coal Burned
Quality A    Emissions Factors Applicability

References EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards. Research Triangle Park, North Carolina.
AP 42 Section Chapter 1   Section 1.1
Formula
Notes Expressed as NO2. Generally, 95+ volume % of nitrogen oxides present in combustion exhaust will be in the form of NO, the rest NO2. To express factors as NO, multiply factors by 0.66.