Emission Factor Details
SCC | 10300206 | ||
Level 1 | External Combustion Boilers | ||
Level 2 | Commercial/Institutional | ||
Level 3 | Bituminous/Subbituminous Coal | ||
Level 4 | Pulverized Coal: Dry Bottom (Bituminous Coal) | ||
POLLUTANT | PM, filterable | NEI PM-FIL | CAS |
Primary Control
ROTOCLONE |
|||
Emission Factor | Formula Lb per Ton Bituminous Coal Burned | Revoked on 09/01/1998 | |
Quality | E Emissions Factors Applicability | ||
References | EPA. 1995. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards. Research Triangle Park, North Carolina. | ||
AP 42 Section | Chapter 1 Section 1.1 | ||
Formula | 2E-2 * (% Ash Content) | ||
Notes | Does not include condensible PM. Multiply the emission factor provided by the weight percent of the ash content of the coal to obtain lb/ton EF. |