Emission Factor Details

SCC 10300203
  Level 1 External Combustion Boilers
  Level 2 Commercial/Institutional
  Level 3 Bituminous/Subbituminous Coal
  Level 4 Cyclone Furnace (Bituminous Coal)
POLLUTANT Benzo(a)anthracene NEI 56553 CAS 56-55-3
  Primary Control       DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER

Emission Factor 8.000E-8 Lb per Ton Bituminous Coal Burned
Quality B    Emissions Factors Applicability

References EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards. Research Triangle Park, North Carolina.
AP 42 Section Chapter 1   Section 1.1
Formula
Notes ESP or FABRIC FILTER only & WET LIMESTONE SCRUBBER or SPRAY DRYER w/ESP or FABRIC FILTER