Emission Factor Details

SCC 10100101
  Level 1 External Combustion Boilers
  Level 2 Electric Generation
  Level 3 Anthracite Coal
  Level 4 Pulverized Coal
POLLUTANT PM, condensable NEI PM-CON CAS
  Primary Control       ROTOCLONE

Emission Factor Formula Lb per Ton Anthracite Burned
Quality E    Emissions Factors Applicability

References EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards. Research Triangle Park, North Carolina.
AP 42 Section Chapter 1   Section 1.1
Formula (1E-1*S-3E-2)*24.6
Notes AP-42 does not contain PM-CON EFs for pulverized anthracite coal combustion for electric utility, industrial, and commercial/institutional boilers with and without controls. Factor is for pulverized coal-fired boilers with all PM controls (without flue gas desulfurization controls). Factors should be multiplied by fuel rate on a heat input basis (MMBtu), as fired. To convert to lb/ton of anthracite coal, multiply by 24.6 MMBtu/ton. 80% of the condensable PM is inorganic; 20% of the condensable PM is organic.