Emission Factor Details
SCC | 10200907 | ||
Level 1 | External Combustion Boilers | ||
Level 2 | Industrial | ||
Level 3 | Wood/Bark Waste | ||
Level 4 | Wood Cogeneration | ||
POLLUTANT | Polychlorinated dibenzofurans, total | NEI 136677106 | CAS |
Primary Control
DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER |
|||
Emission Factor | 2.900E-8 Lb per Ton Wood Burned | ||
Quality | C Emissions Factors Applicability | ||
References | EPA. February, 1999. Section 1.6, Wood Waste Combustion In Boilers. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards. Research Triangle Park, North Carolina. | ||
AP 42 Section | Chapter 1 Section 1.6 | ||
Formula | |||
Notes | Units are lb of pollutant/ton of wood waste burned. Emission factors are based on wet, as-fired wood waste with average properties of 50 weight% moisture and 4500 Btu/lb higher heating value. Emission factor represents measurements from wood waste combustors equipped with PM controls (i.e., fabric filters, multi-cyclones, ESP, and wet scrubbers). Emission factor is for total furans, not toxic equivalents. Excludes data from the combustion of salt-laden wood. | ||
Multiple Factor Info |
0 duplicate factors.
This one is different because... Factor is for combustion on salt-laden wood. |