Emission Factor Details
SCC | 10200904 | ||
Level 1 | External Combustion Boilers | ||
Level 2 | Industrial | ||
Level 3 | Wood/Bark Waste | ||
Level 4 | Bark-fired Boiler (< 50,000 Lb Steam) ** | ||
POLLUTANT | PM, primary | NEI PM-PRI | CAS |
Primary Control
FABRIC FILTER - LOW TEMPERATURE , I.E. T<180F |
|||
Emission Factor | 1.400E1 Lb per Ton Bark Burned | Revoked on 12/01/1999 | |
Quality | D Emissions Factors Applicability | ||
References | EPA. February, 1999. Section 1.6, Wood Waste Combustion In Boilers. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards. Research Triangle Park, North Carolina. | ||
AP 42 Section | Chapter 1 Section 1.6 | ||
Formula | |||
Notes | Units are lb of pollutant/ton of wood waste burned. Emission factors are based on wet, as-fired wood waste with average properties of 50 weight% moisture and 4500 Btu/lb higher heating value. |