Emission Factor Details
SCC | 10200222 | ||
Level 1 | External Combustion Boilers | ||
Level 2 | Industrial | ||
Level 3 | Bituminous/Subbituminous Coal | ||
Level 4 | Pulverized Coal: Dry Bottom (Subbituminous Coal) | ||
POLLUTANT | PM, condensable organics | NEI | CAS |
Primary Control
DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER |
|||
Emission Factor | Formula Lb per MMBtu Heat Input | Revoked on 09/01/2000 | |
Quality | E Emissions Factors Applicability | ||
References | EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards. Research Triangle Park, North Carolina. | ||
AP 42 Section | Chapter 1 Section 1.1 | ||
Formula | 2E-1*(1E-1*S-3E-2) | ||
Notes | Factor is for pulverized coal-fired boilers with all PM controls (without flue gas desulfurization controls). Factors should be multiplied by fuel rate on a heat input basis (MMBtu), as fired. To convert to lb/ton os subbituminous coal, multiply by 20 MMBtu/ton. To convert to lb/ton of bituminous coal, multiply by 26 MMBtu/ton. S= coal sulfur percent by weight as fired. For example, if the sulfur percent is 1.04, then S=1.04. If the coal sulfur percent is 0.4 or less, use a default emission factor of 0.01 lb/MMBtu rather than the emission equation. |