Emission Factor Details

SCC 10200205
  Level 1 External Combustion Boilers
  Level 2 Industrial
  Level 3 Bituminous/Subbituminous Coal
  Level 4 Overfeed Stoker
POLLUTANT PM2.5, filterable NEI PM25-FIL CAS
  Primary Control       CHEMICAL REDUCTION

Emission Factor 2.200E0 Lb per Ton Bituminous Coal Burned
Quality E    Emissions Factors Applicability

References EPA. September, 1998. Section 1.1, Bituminous and Subbituminous Coal Combustion. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards. Research Triangle Park, North Carolina.
AP 42 Section Chapter 1   Section 1.1
Formula
Notes Includes traveling grate, vibrating grate and chain grate stokers. From AP-42, Tables 1.1-4 and 1.1-10. For PM25-FIL emission factor quality rating, applied rating of E for PM10-FIL from Table 1.1-4 which is deemed more reliable than the rating of C for PM25-FIL from Table 1.1-10.