Emission Factor Details

SCC 10100901
  Level 1 External Combustion Boilers
  Level 2 Electric Generation
  Level 3 Wood/Bark Waste
  Level 4 Bark-fired Boiler
POLLUTANT PM, filterable NEI PM-FIL CAS
  Primary Control       CATALYTIC AFTERBURNER

Emission Factor 9.000E0 Lb per Ton Wood Waste Burned Revoked on 09/01/2003
Quality B    Emissions Factors Applicability

References EPA. February, 1999. Section 1.6, Wood Waste Combustion In Boilers. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement E. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards. Research Triangle Park, North Carolina.
AP 42 Section Chapter 1   Section 1.6
Formula
Notes Emission factors are based on wet, as-fired wood waste with average properties of 50 weight percent moisture and 2,500 kcal/kg (4,500 Btu/lb) higher heating value.