Emission Factor Details

SCC 10100901
  Level 1 External Combustion Boilers
  Level 2 Electric Generation
  Level 3 Wood/Bark Waste
  Level 4 Bark-fired Boiler
POLLUTANT Phenol NEI 108952 CAS 108-95-2
  Primary Control       DIRECT FLAME AFTERBURNER WITH HEAT EXCHANGER

Emission Factor 1.470E-5 Lb per Ton Bark Burned Revoked on 02/01/1999
Quality C    Emissions Factors Applicability

References EPA. February, 1998. Section 1.6, Wood Waste Combustion In Boilers. In: Compilation of Air Pollutant Emission Factors, Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Supplement D. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards. Research Triangle Park, North Carolina.
AP 42 Section Chapter 1   Section 1.6
Formula
Notes Units are lb of pollutant/ton of wood waste burned. Emission factors are based on wet, as-fired wood waste with average properties of 50 weight% moisture and 4500 Btu/lb higher heating value. Emission factor represents measurements from wood waste combustors equipped with PM controls (i.e., fabric filters, multi-cyclones, ESP, and wet scrubbers). Emission factor value includes phenol, which is a hazardous air pollutant (HAP), plus substituted phenols which are not HAPs.